Building Services Components and Requirements Quiz
12 Questions
3 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What type of rooms require fire dispersal areas if they are more than 30.00 meters from the nearest exit?

  • Storage rooms
  • Dressing rooms (correct)
  • Workshops
  • Rehearsal rooms
  • Which type of building must have at least one dry standpipe according to the text?

  • Buildings with more than 3 storeys (correct)
  • Buildings with more than 5 storeys
  • Buildings with more than 2 storeys
  • Buildings with more than 1 storey
  • What material are dry standpipes required to be made of according to the text?

  • Aluminum
  • Wrought iron or galvanized steel (correct)
  • Plastic
  • Copper
  • Who should conduct the tests on the dry standpipes?

    <p>Owner of the building or contractor</p> Signup and view all the answers

    Which rooms necessitate the presence of safe fire dispersal areas according to the text?

    <p>Rooms used for handling of x-ray films</p> Signup and view all the answers

    What water pressure should dry standpipes be able to withstand as mentioned in the text?

    <p>$20$ kilograms per square centimeter</p> Signup and view all the answers

    Which of the following is NOT a component of building services mentioned in the text?

    <p>Landscaping services</p> Signup and view all the answers

    According to the requirements for washrooms and toilets, what is the minimum turning space required outside the closet stall for wheelchairs?

    <p>2.25 sq.m.</p> Signup and view all the answers

    What is the maximum height requirement for water closets (toilets) according to the text?

    <p>0.45 m.</p> Signup and view all the answers

    Based on the information provided, what is the minimum number of accessible water closets required on each floor level for buildings with more than 20 total water closets?

    <p>2</p> Signup and view all the answers

    According to the National Building Code requirements on fire safety, in what types of areas must standard automatic fire-extinguishing systems be installed?

    <p>Any area used for habitation, recreation, dining, study, or work with an area of 200 square meters or more and an occupant load of more than 20</p> Signup and view all the answers

    What is the maximum height requirement for lavatories (sinks) with knee recess according to the text?

    <p>0.80 m.</p> Signup and view all the answers

    More Like This

    Building Services Industry Roles Quiz
    3 questions
    Components of Building Services Quiz
    12 questions
    Building Services Engineering Quiz
    36 questions

    Building Services Engineering Quiz

    SweetheartMandelbrot1035 avatar
    SweetheartMandelbrot1035
    Use Quizgecko on...
    Browser
    Browser