Building Services Components Quiz
12 Questions
2 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the minimum required size of a wheelchair-accessible washroom stall according to the text?

  • 1.80 x 1.70 m
  • 1.70 x 1.50 m
  • 1.70 x 1.80 m (correct)
  • 2.00 x 2.00 m
  • What is the maximum height of a water closet (toilet) according to the text?

  • 0.45 m (correct)
  • 0.40 m
  • 0.55 m
  • 0.50 m
  • What is the minimum number of accessible water closets (toilets) required on each floor level for a building with more than 20 total water closets per floor?

  • 1 for every 20 total
  • 1 for every 10 total
  • 2 for more than 20 total (correct)
  • 1 for every 15 total
  • What is the maximum height of a lavatory (sink) according to the text?

    <p>0.80 m</p> Signup and view all the answers

    When are automatic fire-extinguishing systems required to be installed?

    <p>In every storey, basement or cellar with an area of 200 square meters or more and an occupant load of more than 20</p> Signup and view all the answers

    What type of HVAC support engines are mentioned in the text?

    <p>No specific HVAC support engines are mentioned</p> Signup and view all the answers

    What is the minimum occupant load required for a room to necessitate the presence of dry standpipes?

    <p>More than 500</p> Signup and view all the answers

    What material should dry standpipes be made of?

    <p>Wrought iron</p> Signup and view all the answers

    What water pressure should dry standpipes be able to withstand when ready for service?

    <p>20 kilograms per square centimeter</p> Signup and view all the answers

    Who is responsible for conducting tests on dry standpipes?

    <p>Owner of the building or contractor</p> Signup and view all the answers

    Which type of rooms specifically require the presence of dry standpipes?

    <p>Rooms with an occupant load of more than 500</p> Signup and view all the answers

    What should the dry standpipes be strong enough to withstand without leaking at joints, valves, or fittings?

    <p>$20(4 + 1)$ kilograms per square meter</p> Signup and view all the answers

    Study Notes

    Fire Safety Requirements

    • Automatic fire-extinguishing systems are required in areas with an occupant load of more than 20, including habitational, recreational, dining, study, and work areas with an area of 200 square meters or more.
    • Fire-extinguishing systems are also required in dressing rooms, rehearsal rooms, workshops or factories with an occupant load of more than 10, and in assembly halls with an occupant load of more than 500, if the nearest exit is more than 30 meters away.

    Standpipes

    • Dry standpipes are required in buildings four or more storeys in height, made of wrought iron or galvanized steel, and must withstand 20 kg/cm² water pressure.
    • Tests must be conducted by the building owner or contractor in the presence of a Building representative.

    Sanitary Services

    • Washrooms and toilets must meet BP 344 requirements, including:
      • Minimum size of 1.70 x 1.80 m with grab bars.
      • Turning space of 2.25 sq.m with a minimum of 1.50 m for wheelchairs outside the closet stall.
      • Minimum number of accessible water closets on each floor level: 1 for every 20, and 2 for more than 20.
      • Maximum height of water closet: 0.45 m, flush control: 1.20 m.
      • Maximum height of lavatories: 0.80 m with knee recess 0.60 to 0.70 m vertical clearance and 0.50 m depth.

    Mechanical Services

    • Air-con duct systems require HVAC support engines.

    Escalator System

    • Escalator system requirements are stated but not specified in the provided text.

    Fire Fighting Services

    • Building safety requirements include fire-extinguishing systems and other fire safety measures as per the National Building Code.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Test your knowledge on the components of building services including sanitary or plumbing services, electrical services, mechanical services, and fire protection systems. Explore requirements for plumbing and sanitary services as per RA 6541.