The initials BSI stand for?

  • British Standards Institution (correct)
  • Building Specifications Institution
  • British Standards Instruction
  • British Specifications Institution
  • What is the minimum depth for an underground cold water service pipe?

  • 750 mm (correct)
  • 450 mm
  • 150 mm
  • 1350 mm
  • Before turning off the water supply to a dwelling, what is the first action a plumber should take?

  • Advise their supervisor
  • Advise the local Authority
  • Advise the Water Company
  • Advise the householder (correct)
  • Type 'A' fittings are also known as?

    <p>Non-manipulative compression (A)</p> Signup and view all the answers

    Which type of cold water system should be specified for a domestic dwelling in an area where the water supply is poor during periods of peak demand?

    <p>Indirect (A)</p> Signup and view all the answers

    On a cistern supplying an indirect cold water system, where should the cold feed outlet to the domestic hot water cylinder be located?

    <p>Higher than the cold distribution outlet (C)</p> Signup and view all the answers

    What is the recommended clip spacing for a horizontal cold water service pipe in 15 mm copper?

    <p>1.2 m (A)</p> Signup and view all the answers

    Refer to Figure 1. The system component indicated by the British Standard symbol shown, is a

    <p>Check valve (C)</p> Signup and view all the answers

    What is the required distance between the water level and the invert level of the warning pipe, on a cold water storage cistern of less than 1000 litres capacity?

    <p>25 mm (B)</p> Signup and view all the answers

    What is the main advantage of an indirect cold water system, compared to a direct cold water system?

    <p>There is a reserve of water should the mains supply be turned off (C)</p> Signup and view all the answers

    Refer to Figure 2. The type of fitting shown is

    <p>Type A non-manipulative compression fitting (C)</p> Signup and view all the answers

    What is the purpose a cold water distributing pipe in an indirect system of cold water supply?

    <p>Supply the water to the various cold water appliances within the system (C)</p> Signup and view all the answers

    Which of the following types of fittings would usually be installed on a supply pipe as it enters a domestic dwelling?

    <p>Supply stop valve and drain valve (A)</p> Signup and view all the answers

    Which one of the following shut off devices would be an acceptable choice for a new WC cistern on a direct cold water system?

    <p>Equilibrium valve (D)</p> Signup and view all the answers

    The Water Regulations specify two categories of test, one for rigid pipe installations, and one for systems containing?

    <p>Plastics (C)</p> Signup and view all the answers

    According to the Water Regulations, what percentage of the normal working pressure should the test pressure be, when testing rigid pipe installations?

    <p>50% above (B)</p> Signup and view all the answers

    Which one of the following can a plumber establish about a cold water system, by inspecting the cold water storage cistern and pipework arrangements?

    <p>If it is direct or indirect (A)</p> Signup and view all the answers

    Before working on a shower pump, what should the plumber do?

    <p>Isolate the shower pump from the electrical supply at the consumer unit, remove and retain the fuse, and check for safe isolation (D)</p> Signup and view all the answers

    Which one of the following should be turned off to isolate the float valve to the cold water storage cistern, on a new cold water system conforming to the Water Regulations?

    <p>Supply pipe service valve (C)</p> Signup and view all the answers

    What is the main reason for placing a warning notice on the stop valve when temporarily decommissioning a system?

    <p>Prevent the service from being accidentally re-activated (A)</p> Signup and view all the answers

    Which one of the following is responsible for ensuring decommissioning records are provided to customers, when undertaking work on a multi-trade site?

    <p>Main Contractor (C)</p> Signup and view all the answers

    What is the most cost effective method of repairing a 'jammed' internal supply stop valve?

    <p>Replace the valve head gear (B)</p> Signup and view all the answers

    Which one of the following is most likely to be included in a routine maintenance schedule for a cold water system in a dwelling?

    <p>Checking the operation of taps and valves (B)</p> Signup and view all the answers

    What is the most likely cause of noise in a cold water system?

    <p>Water pressure being too high (B)</p> Signup and view all the answers

    Why is it important to notify the customer prior to the water supply being turned off during a lengthy maintenance operation?

    <p>So that the customer can store some water for drinking purposes (A)</p> Signup and view all the answers

    In which one of the following types of float valve, is it possible to replace the piston?

    <p>Brass portsmouth (B)</p> Signup and view all the answers

    During which one of the following maintenance operations would it be necessary to wear a dust mask?

    <p>Gaining access to a roof space to replace a CWSC (B)</p> Signup and view all the answers

    Guidance on the installation requirements for external water meters is covered by:

    <p>BS 6700 (D)</p> Signup and view all the answers

    Which one of the following areas of work is covered by the Water Regulations?

    <p>All types of work on mains cold water systems (C)</p> Signup and view all the answers

    What is the main purpose of a ceramic disc in a pillar tap??

    <p>Control the flow of water (A)</p> Signup and view all the answers

    If a cold water system in a dwelling is not thoroughly flushed out prior to hand over, what could happen?

    <p>Taps and valves may not perform to design specification (D)</p> Signup and view all the answers

    Which one of the following documents would be the most appropriate to a maintenance contract for domestic dwellings?

    <p>Manufacturer's Instructions (B)</p> Signup and view all the answers

    Only when a cold water pillar tap is opened does water appear from beneath the hand wheel. This problem can be rectified by:

    <p>Re-packing the gland (D)</p> Signup and view all the answers

    Whilst working on a maintenance job, a plumber suspects that a communication pipe has burst. The most appropriate course of action would be to:

    <p>Arrange for the local Water Undertaker to be advised (C)</p> Signup and view all the answers

    What is the minimum height required for maintenance above a cistern of 1000 L or less?

    <p>350 mm (B)</p> Signup and view all the answers

    A common cause of pin-holing in copper cold water supply pipework, is because the water:

    <p>Is acidic (B)</p> Signup and view all the answers

    What is the most probable cause of an intermittent supply to cold water taps fed from an indirect system?

    <p>An air lock in the distribution pipework (A)</p> Signup and view all the answers

    When carrying out fault finding in an occupied dwelling, what should be the first action?

    <p>Obtain details from the householder about the fault (A)</p> Signup and view all the answers

    One common cause of air locks in an indirect supply to cold tap outlets is that horizontal sections of the:

    <p>Distribution pipework is rising from the cistern (C)</p> Signup and view all the answers

    Rigid screw-in type silencer tubes to float valves are now prohibited because they could:

    <p>Cause backflow of water and contaminate the supply (A)</p> Signup and view all the answers

    Following the commissioning of a new cold water installation, the water flow from the float valve to the cold water storage cistern is very slow. What is the most likely reason?

    <p>System was not flushed properly, and grit has accumulated at the float valve orifice (B)</p> Signup and view all the answers

    What is the greatest potential risk of water stagnation in a dwelling?

    <p>In linked cold water storage cisterns with unequal draw-offs from each (B)</p> Signup and view all the answers

    Bonding wire should be secured to metal pipework using:

    <p>An earth clip (D)</p> Signup and view all the answers

    What is the purpose of applying temporary earth continuity bonding before removing a section of metallic cold water pipe?

    <p>Ensure that all exposed metallic parts of the system remain connected to earth while carrying out the work (B)</p> Signup and view all the answers

    Refer to Figure 3. The Type of fitting shown is a

    <p>quarter turn tap (B)</p> Signup and view all the answers

    Flashcards

    BSI

    British Standards Institution.

    Minimum depth for cold water service pipe

    The minimum depth is 750 mm.

    First action before water supply is turned off

    A plumber should advise the householder.

    Type 'A' fittings

    Also known as non-manipulative compression fittings.

    Signup and view all the flashcards

    Cold water system for poor supply

    Indirect system is recommended.

    Signup and view all the flashcards

    Cold feed outlet position

    Should be lower than the cold distribution outlet.

    Signup and view all the flashcards

    Clip spacing for 15 mm copper

    Recommended spacing is 1.2 m.

    Signup and view all the flashcards

    Warning pipe distance

    Required distance is 25 mm.

    Signup and view all the flashcards

    Indirect system advantage

    Has a reserve of water if mains supply is off.

    Signup and view all the flashcards

    Supply pipe system fittings

    Usually includes supply stop and check valve.

    Signup and view all the flashcards

    Float valve isolation

    Turn off the supply stop valve.

    Signup and view all the flashcards

    Decommissioning notice purpose

    To prevent accidental re-activation.

    Signup and view all the flashcards

    Common cause of plumbing noise

    Most likely due to high water pressure.

    Signup and view all the flashcards

    Action when air lock suspected

    Inspect horizontal pipe sections.

    Signup and view all the flashcards

    Temporary earth continuity bonding purpose

    To keep the system grounded while working.

    Signup and view all the flashcards

    Cause of pin-holing in copper pipes

    Most often caused by acidic water.

    Signup and view all the flashcards

    Float valve flow issue post-commissioning

    Slow flow likely due to improper flushing.

    Signup and view all the flashcards

    Maintenance height above cistern

    Minimum height is 250 mm.

    Signup and view all the flashcards

    Water stagnation risk location

    High in linked cisterns with unequal draw-offs.

    Signup and view all the flashcards

    Common maintenance check

    Checking operation of taps and valves.

    Signup and view all the flashcards

    Troubleshooting first step

    Get details from the householder about the fault.

    Signup and view all the flashcards

    Water Regulation coverage

    Covers all types of work on mains cold water systems.

    Signup and view all the flashcards

    Maintenance document for dwellings

    Most appropriate is the Manufacturer's Instructions.

    Signup and view all the flashcards

    Action on suspected burst communication pipe

    Advise the local Water Undertaker.

    Signup and view all the flashcards

    Cause of intermittent cold water supply

    Air lock in the distribution pipework.

    Signup and view all the flashcards

    Tool for checking metal pipe bonding

    Use an earth clip for securing wiring.

    Signup and view all the flashcards

    Float valve piston replacement options

    Replaceable in brass portsmouth type.

    Signup and view all the flashcards

    Required distance for cistern maintenance

    150 mm above the cistern is necessary.

    Signup and view all the flashcards

    Ceramic disc function in taps

    Controls the flow of water effectively.

    Signup and view all the flashcards

    Study Notes

    Cold Water Mock 3 - Study Notes

    • BSI: British Standards Institution
    • Underground cold water service pipe minimum depth: 150mm
    • Plumber's first action before turning off water supply: Advise the householder
    • Type 'A' fittings: Also known as non-manipulative compression fittings
    • Cold water system for peak demand: Specify an indirect system
    • Indirect cold water system, cold feed outlet: Higher than the cold distribution outlet
    • Horizontal cold water service pipe (15mm copper) clip spacing: 1.2m
    • British Standard symbol (Figure 1): Supply stop valve
    • Water level to invert level (warning pipe): 20mm (for cisterns under 1000L capacity)
    • Advantage of indirect cold water systems: Less pipework and fittings, reduced installation costs
    • Fitting (Figure 2): Type B manipulative compression fitting
    • Purpose of cold water distributing pipe (indirect system): Supply water to cold water appliances
    • Fittings for domestic dwelling: Supply stop valve and check valve
    • WC cistern shut-off device: Equilibrium valve
    • Water Regulations rigid pipe installations and other systems: The regulations specify two testing categories, one for rigid pipe installations and one for systems containing lead, LCS, plastics, or copper.
    • Test pressure for rigid pipe installations: 10% below specified normal working pressure
    • Plumber's cold water system inspection: Determine if the system is direct or indirect, assess the number of appliances, and gauge likely water pressure
    • Shower pump maintenance: Isolate the shower pump from the electrical supply at the consumer unit and remove and retain the fuse.
    • Important customer notification: Notify the customer prior to turning off the water supply during lengthy maintenance operations, as it is a statutory requirement of the Water Regulations.
    • Cold water storage cistern float valve isolation: Supply stop valve.
    • Reason for warning notice on stop valve: Prevent the possibility of backflow, prevent accidental reactivation
    • Decommissioning record responsibility: Main contractor or local authority
    • Repairing a jammed internal supply stop valve: Isolate the supply, disconnect, and replace.
    • Maintenance schedule for cold water: Checking the operation of taps and valves.
    • Cause of noise in cold water system: Air bubbles
    • Cold water tap fitting type (Figure 3): Quarter turn tap
    • Float valve piston replacement capability: Brass diaphragm type.
    • Maintenance operation requiring a dust mask: Chemical disinfection of a cold water system
    • Water meter installation guidance: BS 8301
    • Water Regulations coverage: New cold water system installations, maintenance of cold water installations.
    • Ceramic disc purpose (pillar tap): Water flow control, prevents water hammer
    • Cold water system stagnation risk: Stagnant water in a cold water system that has not been disinfected.
    • Repairing a cold water tap: Re-packing the gland
    • Pipework pinhole cause: Acidic water
    • Intermittent supply cause (indirect system): Air lock in distribution pipework

    Cold Water Mock 3 - Additional Notes

    • Figure references refer to diagrams in the provided text. The figures are not included in this summary.
    • Multiple questions and answers are summarized, so this document may include similar concepts in slightly different formats.
    • Information on recommended clip spacing and distances were included as well.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    Description

    This quiz covers essential concepts related to cold water systems used in plumbing, including British Standards and types of fittings. Test your knowledge on the specifications and advantages of both direct and indirect cold water systems. Perfect for plumbing students and professionals seeking to deepen their understanding.

    More Like This

    Indirect Cold Water Systems Quiz
    3 questions
    3B Components of Domestic Cold Water Systems
    40 questions
    6 Domestic Cold Water Systems Maintenance
    32 questions
    Cold Water Mock Test 1
    45 questions

    Cold Water Mock Test 1

    AdvancedCourage8795 avatar
    AdvancedCourage8795
    Use Quizgecko on...
    Browser
    Browser