Cold Water Systems Installation Quiz
45 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

Details of the minimum amount of headroom required above a Cold Water Storage Cistern, to enable maintenance work, can be found in the

  • Installation plan
  • Job specification
  • Water Regulations Guide. (correct)
  • Construction Regulations
  • The minimum diameter of an incoming cold water service pipe to a dwelling is

  • 12 mm
  • 28 mm.
  • 15 mm (correct)
  • 22 mm
  • The incoming water flow rate to a property has been confirmed as 6 litres / minute. What is this reading in litres / second?

  • 0.61 /s.
  • 0.11/s. (correct)
  • 0.061/s.
  • 0.121/s.
  • Which one of the following is not approved for use in Cold Water Systems installation?

    <p>Solder fittings with lead / tin solder. (B)</p> Signup and view all the answers

    A Cold Water System where all cold water draw-off points, except the draw-off point at the sink, are fed from a storage cistern is called

    <p>an Indirect Cold Water System (A)</p> Signup and view all the answers

    A Cold Water Service pipe to a dwelling should be laid between

    <p>750 mm and 1350 mm below ground level (A)</p> Signup and view all the answers

    The correct tool for cutting holes in a plastic Cold Water Storage cistern is a

    <p>hole saw (A)</p> Signup and view all the answers

    The British Standard symbol shown in Figure 1 indicates a

    <p>supply stop valve (B)</p> Signup and view all the answers

    With reference to Cold Water Storage cisterns, a common warning and overflow pipe should be used with cisterns of less than which of the following capacities?

    <p>1000 litres. (B)</p> Signup and view all the answers

    Which one of the following should be positioned immediately above the cold water supply stop valve, near the point of entry to a building?

    <p>Drain valve. (A)</p> Signup and view all the answers

    Which one of the following methods of jointing copper tube should not be used for underground service pipe connections?

    <p>Type A, non-manipulative compression fitting (A)</p> Signup and view all the answers

    When the cylinder cold feed and a cold distributing pipe are connected to the same cold water storage cistern, the

    <p>cold distribution pipe must be lower than the cylinder cold feed pipe. (D)</p> Signup and view all the answers

    Which one of the following pipes should be connected to a cold water storage cistern by means of a filtered connection?

    <p>Overflow / warning pipe. (B)</p> Signup and view all the answers

    Which one of the following must not be used for making connections between systems pipework and cold water storage cisterns?

    <p>Oil based jointing compounds. (C)</p> Signup and view all the answers

    The Water Regulations require that the soundness test period on accessible copper cold water supply pipes shall be for

    <p>one hour, at a test pressure of 1.5 times the working pressure. (D)</p> Signup and view all the answers

    Which one of the following shows the type of soundness test required by the Water Regulations for Cold Water systems?

    <p>Hydraulic test. (D)</p> Signup and view all the answers

    When building or water systems plans are not available, it can be established if the cold water system installed in a dwelling is a direct or an indirect supply system by

    <p>inspecting the pipework connections from the cold water cistern (D)</p> Signup and view all the answers

    Major refurbishment is being carried out on a large occupied dwelling. Which one of the following should be advised before the cold water supply to the dwelling is taken out of service?

    <p>The customer and other trades. (C)</p> Signup and view all the answers

    Which one of the following must be carried out prior to commencing work on moving an instantaneous electric water heater, from over a sink to a new position?

    <p>Isolate the heater from the electrical supply at the consumer unit, by removing and retaining the fuse, and check for safe isolation. (C)</p> Signup and view all the answers

    The Cold Water supply pipe at the supply stop valve must be cut or disconnected and blanked off

    <p>when a system is being permanently decommissioned (C)</p> Signup and view all the answers

    When a cold water system is temporarily decommissioned to permit maintenance work, it is advisable to place a warning notice saying 'do not turn on' when

    <p>the cold water supply is turned off at the main stop valve to permit the installation of a WC (D)</p> Signup and view all the answers

    A record of the decommissioning of a cold water system should be completed for

    <p>systems installed in industrial premises (C)</p> Signup and view all the answers

    Information regarding the maintenance requirements for a shower mixer can be found in

    <p>the manufacturer's instructions (D)</p> Signup and view all the answers

    Which of the following is most likely to present a water contamination risk?

    <p>Incorrectly linked cold water storage cisterns. (B)</p> Signup and view all the answers

    Which one of the following trades may require a temporary cold water supply when the main supply is to be isolated for maintenance purposes?

    <p>Bricklaying. (C)</p> Signup and view all the answers

    Ceramic discs would be required to carry out maintenance on a

    <p>quarter turn pillar tap (B)</p> Signup and view all the answers

    In which one of the following cold water components is it possible to replace the valve seating?

    <p>Float valve to BS 1212. (C)</p> Signup and view all the answers

    Safe access equipment will usually be required when working on

    <p>the float valve to a cold water storage cistern. (D)</p> Signup and view all the answers

    The performance specification for a water softener can be found in the

    <p>manufacturer's technical information (B)</p> Signup and view all the answers

    Statutory requirements covering the capacity of WC cisterns can be found in the

    <p>Water Supply (Water Fittings) Regulations 1999 (D)</p> Signup and view all the answers

    Which one of the following system components is maintained by checking the spindle action for ease of opening and closing after tightening the packing gland?

    <p>Fullway valve. (C)</p> Signup and view all the answers

    Which one of the following system components is maintained by checking the opening and closing action and adjusting for correct water level?

    <p>Float valve. (A)</p> Signup and view all the answers

    A plumber cannot rectify a fault with a plumbing system. On leaving the property, which of the following is the best course of action to avoid a potential complaint from the customer in the future?

    <p>Advise the customer verbally and complete a job record. (A)</p> Signup and view all the answers

    A plumber finds that routine servicing and maintenance of a sink mixer valve does not correct a fault in the component. The plumber should

    <p>seek advice from his / her supervisor on the next steps (C)</p> Signup and view all the answers

    It is necessary to carry out maintenance on the cold water supply stop valve in an office block. The work is not expected to take longer than 3 hours, and the system is a Direct Cold Water System. The appropriate action required to minimise cost and inconvenience would be to

    <p>take all toilet accommodation out of use and place warning notices on all toilet doors to advise building occupants that the WCs cannot be used until work has finished (D)</p> Signup and view all the answers

    The minimum distance below the invert of the warning pipe, at which the water level should be set in a cold water storage cistern after re-washering the float valve, is

    <p>25 mm (C)</p> Signup and view all the answers

    Which one of the following installation practices helps to reduce noise in copper pipework?

    <p>Ensuring that pipework is suitably and securely fixed. (D)</p> Signup and view all the answers

    A supply pipe is leaking where it enters a house in a tiled shower room. The pipe is copper, the leak is just above floor level and the pipe in the area of the leak is green. The most likely cause of the problem would be that the pipe

    <p>has been corroded by cleaning materials (C)</p> Signup and view all the answers

    When a screw down pillar tap on a sink drainer is opened, there is a high pitched vibration or whistling noise. The probable cause is that

    <p>a washer is split or loose (C)</p> Signup and view all the answers

    When a cold water sink pillar tap is turned off quickly, there is a loud banging from the pipe duct in which the supply pipe rises to the bathroom, and cold water storage cistern. The appropriate action to rectify this problem is to

    <p>check that the pipework is securely clipped and add additional fixings if required (C)</p> Signup and view all the answers

    Water Regulations do not permit the fixing of rigid screw-in type silencer tubes to float valves, because such devices

    <p>could cause backflow of water and subsequent contamination of the water supply (A)</p> Signup and view all the answers

    The amount of noise being caused by a float valve in a storage cistern can be reduced by

    <p>clearing any grit or debris that has accumulated in the valve orifice. (A)</p> Signup and view all the answers

    The renewal of a section of copper pipework to a washbasin has to be left overnight for completion the next day. Which one of the following precautions should be taken in addition to closing the service valves to the wash basin?

    <p>Put 'push-fit' cap ends over any open pipework. (B)</p> Signup and view all the answers

    When renewing a cold feed and expansion cistern to an Indirect Domestic Hot Water System, the isolating valve to the cistern must be closed, and the

    <p>fuse for the hot water heating appliance from the consumer unit removed (B)</p> Signup and view all the answers

    Before removing a section of copper pipework for maintenance purposes, all necessary controls must be closed, appropriate sections of pipework must be drained and

    <p>temporary earth continuity bonding must be applied (D)</p> Signup and view all the answers

    Study Notes

    Cold Water Mock 1

    • Minimum Headroom: Details for minimum headroom above a cold water storage cistern for maintenance are found in the: Installation plan, Construction Regulations, Job specification, or Water Regulations Guide.
    • Cold Water Service Pipe Diameter: The minimum diameter for an incoming cold water service pipe to a dwelling is 28 mm.
    • Water Flow Rate Conversion: A water flow rate of 6 litres per minute is equivalent to 0.1 litres per second.
    • Unapproved Installation Materials: Push-fit copper fittings, Solder fittings with lead/tin solder, are approved for use in Cold Water Systems installation, but Type 'A' compression fittings are not.
    • Cold Water System Types: A "Direct Cold Water System" is where all cold water draw-off points, except the sink, are fed from a storage cistern. An alternative is an "Indirect System".
    • Cold Water Service Pipe Depth: A cold water service pipe to a dwelling should be laid between 750 mm and 1350 mm below ground level.

    Additional Cold Water Mock 1 Information

    • Plastic Cold Water Storage Cisterns: For cisterns with capacities less than 1000 litres, a common warning/overflow pipe should be used.
    • Cold Water Supply Stop Valve Placement: The servicing valve, automatic air release, should be placed immediately above the stop valve.
    • Underground Copper Pipe Connections: Type A (non-manipulative compression fittings), Integral solder ring capillary fittings, and Endfeed solder capillary fittings are acceptable for underground service pipe connections. Type B (manipulative compression fitting) is not.
    • Cold Water Storage Cistern Connections: The vent pipe, distribution pipe, and cold feed pipe should be connected to the cistern, but not the overflow/warning pipe.
    • Cold Water System Component Connections: Plastic jointing washers, Lead free solder, and Non-manipulative compression fittings are acceptable for connections between systems and cisterns. Oil based jointing compounds are not.
    • Soundness Test Periods: Accessible copper cold water supply pipes must be tested for one hour at 1.5 times the working pressure.
    • Plumbing System Sound Test Requirements: Hydraulic test is required for cold water systems.

    Further Information

    • Cold Water Storage Cistern/Direct/Indirect system Connections: When the cylinder cold feed and cold distribution are connected to the same cold water storage cistern, the two pipes must be connected on opposite sides of the cistern.
    • Cold Water System Maintenance: When removing an appliance from a cold water system, the customer and other trades should be advised before disabling the hot water supply.
    • Cold Water Electrical Supply and Maintenance: The electrical supply to the hot water heater must be isolated before work can be carried out.
    • Temporary Cold Water Supply Requirements: Electrical (or other) trades may require a temporary cold water supply when the main supply is isolated for maintenance.
    • Pipework Maintenance: A plumber should seek supervision or advice and guidance when they cannot rectify a fault in the cold water system component.
    • Cold Water Storage Cistern Capacity: For WC cisterns less than 2000 liters, a warning/overflow pipe should be used.
    • Cold Water Pipework Installation: Removing all flux from soldered pipe fittings before installation, ensuring that fittings are used instead of pipe bends, pipework is fixed properly are recommended for reducing noise in copper pipework.
    • Cold water leak resolution: A suspected leak in a pipe should be inspected for causes like ruptures, corrosion from cleaning products, or air inside the water.
    • Pipework Maintenance/Renewal: A section of copper pipework should be drained; and temporary earth continuity bonding should be considered.
    • Cold Water System Maintenance/Temporary Shutdown/Notifications: When a cold water system is undergoing maintenance, a warning sign should be placed.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    Description

    Test your knowledge on cold water systems installation with this quiz. It covers essential topics such as service pipe diameters, maintenance headroom, and approved materials. Perfect for students or professionals in plumbing and construction fields.

    More Like This

    Indirect Cold Water Systems Quiz
    3 questions
    3A Cold Water Storage Cisterns Quiz
    40 questions
    6 Domestic Cold Water Systems Maintenance
    32 questions
    Use Quizgecko on...
    Browser
    Browser