Details of the minimum amount of headroom required above a Cold Water Storage Cistern, to enable maintenance work, can be found in the
Details of the minimum amount of headroom required above a Cold Water Storage Cistern, to enable maintenance work, can be found in the
The minimum diameter of an incoming cold water service pipe to a dwelling is
The minimum diameter of an incoming cold water service pipe to a dwelling is
The incoming water flow rate to a property has been confirmed as 6 litres / minute. What is this reading in litres / second?
The incoming water flow rate to a property has been confirmed as 6 litres / minute. What is this reading in litres / second?
Which one of the following is not approved for use in Cold Water Systems installation?
Which one of the following is not approved for use in Cold Water Systems installation?
Signup and view all the answers
A Cold Water System where all cold water draw-off points, except the draw-off point at the sink, are fed from a storage cistern is called
A Cold Water System where all cold water draw-off points, except the draw-off point at the sink, are fed from a storage cistern is called
Signup and view all the answers
A Cold Water Service pipe to a dwelling should be laid between
A Cold Water Service pipe to a dwelling should be laid between
Signup and view all the answers
The correct tool for cutting holes in a plastic Cold Water Storage cistern is a
The correct tool for cutting holes in a plastic Cold Water Storage cistern is a
Signup and view all the answers
The British Standard symbol shown in Figure 1 indicates a
The British Standard symbol shown in Figure 1 indicates a
Signup and view all the answers
With reference to Cold Water Storage cisterns, a common warning and overflow pipe should be used with cisterns of less than which of the following capacities?
With reference to Cold Water Storage cisterns, a common warning and overflow pipe should be used with cisterns of less than which of the following capacities?
Signup and view all the answers
Which one of the following should be positioned immediately above the cold water supply stop valve, near the point of entry to a building?
Which one of the following should be positioned immediately above the cold water supply stop valve, near the point of entry to a building?
Signup and view all the answers
Which one of the following methods of jointing copper tube should not be used for underground service pipe connections?
Which one of the following methods of jointing copper tube should not be used for underground service pipe connections?
Signup and view all the answers
When the cylinder cold feed and a cold distributing pipe are connected to the same cold water storage cistern, the
When the cylinder cold feed and a cold distributing pipe are connected to the same cold water storage cistern, the
Signup and view all the answers
Which one of the following pipes should be connected to a cold water storage cistern by means of a filtered connection?
Which one of the following pipes should be connected to a cold water storage cistern by means of a filtered connection?
Signup and view all the answers
Which one of the following must not be used for making connections between systems pipework and cold water storage cisterns?
Which one of the following must not be used for making connections between systems pipework and cold water storage cisterns?
Signup and view all the answers
The Water Regulations require that the soundness test period on accessible copper cold water supply pipes shall be for
The Water Regulations require that the soundness test period on accessible copper cold water supply pipes shall be for
Signup and view all the answers
Which one of the following shows the type of soundness test required by the Water Regulations for Cold Water systems?
Which one of the following shows the type of soundness test required by the Water Regulations for Cold Water systems?
Signup and view all the answers
When building or water systems plans are not available, it can be established if the cold water system installed in a dwelling is a direct or an indirect supply system by
When building or water systems plans are not available, it can be established if the cold water system installed in a dwelling is a direct or an indirect supply system by
Signup and view all the answers
Major refurbishment is being carried out on a large occupied dwelling. Which one of the following should be advised before the cold water supply to the dwelling is taken out of service?
Major refurbishment is being carried out on a large occupied dwelling. Which one of the following should be advised before the cold water supply to the dwelling is taken out of service?
Signup and view all the answers
Which one of the following must be carried out prior to commencing work on moving an instantaneous electric water heater, from over a sink to a new position?
Which one of the following must be carried out prior to commencing work on moving an instantaneous electric water heater, from over a sink to a new position?
Signup and view all the answers
The Cold Water supply pipe at the supply stop valve must be cut or disconnected and blanked off
The Cold Water supply pipe at the supply stop valve must be cut or disconnected and blanked off
Signup and view all the answers
When a cold water system is temporarily decommissioned to permit maintenance work, it is advisable to place a warning notice saying 'do not turn on' when
When a cold water system is temporarily decommissioned to permit maintenance work, it is advisable to place a warning notice saying 'do not turn on' when
Signup and view all the answers
A record of the decommissioning of a cold water system should be completed for
A record of the decommissioning of a cold water system should be completed for
Signup and view all the answers
Information regarding the maintenance requirements for a shower mixer can be found in
Information regarding the maintenance requirements for a shower mixer can be found in
Signup and view all the answers
Which of the following is most likely to present a water contamination risk?
Which of the following is most likely to present a water contamination risk?
Signup and view all the answers
Which one of the following trades may require a temporary cold water supply when the main supply is to be isolated for maintenance purposes?
Which one of the following trades may require a temporary cold water supply when the main supply is to be isolated for maintenance purposes?
Signup and view all the answers
Ceramic discs would be required to carry out maintenance on a
Ceramic discs would be required to carry out maintenance on a
Signup and view all the answers
In which one of the following cold water components is it possible to replace the valve seating?
In which one of the following cold water components is it possible to replace the valve seating?
Signup and view all the answers
Safe access equipment will usually be required when working on
Safe access equipment will usually be required when working on
Signup and view all the answers
The performance specification for a water softener can be found in the
The performance specification for a water softener can be found in the
Signup and view all the answers
Statutory requirements covering the capacity of WC cisterns can be found in the
Statutory requirements covering the capacity of WC cisterns can be found in the
Signup and view all the answers
Which one of the following system components is maintained by checking the spindle action for ease of opening and closing after tightening the packing gland?
Which one of the following system components is maintained by checking the spindle action for ease of opening and closing after tightening the packing gland?
Signup and view all the answers
Which one of the following system components is maintained by checking the opening and closing action and adjusting for correct water level?
Which one of the following system components is maintained by checking the opening and closing action and adjusting for correct water level?
Signup and view all the answers
A plumber cannot rectify a fault with a plumbing system. On leaving the property, which of the following is the best course of action to avoid a potential complaint from the customer in the future?
A plumber cannot rectify a fault with a plumbing system. On leaving the property, which of the following is the best course of action to avoid a potential complaint from the customer in the future?
Signup and view all the answers
A plumber finds that routine servicing and maintenance of a sink mixer valve does not correct a fault in the component. The plumber should
A plumber finds that routine servicing and maintenance of a sink mixer valve does not correct a fault in the component. The plumber should
Signup and view all the answers
It is necessary to carry out maintenance on the cold water supply stop valve in an office block. The work is not expected to take longer than 3 hours, and the system is a Direct Cold Water System. The appropriate action required to minimise cost and inconvenience would be to
It is necessary to carry out maintenance on the cold water supply stop valve in an office block. The work is not expected to take longer than 3 hours, and the system is a Direct Cold Water System. The appropriate action required to minimise cost and inconvenience would be to
Signup and view all the answers
The minimum distance below the invert of the warning pipe, at which the water level should be set in a cold water storage cistern after re-washering the float valve, is
The minimum distance below the invert of the warning pipe, at which the water level should be set in a cold water storage cistern after re-washering the float valve, is
Signup and view all the answers
Which one of the following installation practices helps to reduce noise in copper pipework?
Which one of the following installation practices helps to reduce noise in copper pipework?
Signup and view all the answers
A supply pipe is leaking where it enters a house in a tiled shower room. The pipe is copper, the leak is just above floor level and the pipe in the area of the leak is green. The most likely cause of the problem would be that the pipe
A supply pipe is leaking where it enters a house in a tiled shower room. The pipe is copper, the leak is just above floor level and the pipe in the area of the leak is green. The most likely cause of the problem would be that the pipe
Signup and view all the answers
When a screw down pillar tap on a sink drainer is opened, there is a high pitched vibration or whistling noise. The probable cause is that
When a screw down pillar tap on a sink drainer is opened, there is a high pitched vibration or whistling noise. The probable cause is that
Signup and view all the answers
When a cold water sink pillar tap is turned off quickly, there is a loud banging from the pipe duct in which the supply pipe rises to the bathroom, and cold water storage cistern. The appropriate action to rectify this problem is to
When a cold water sink pillar tap is turned off quickly, there is a loud banging from the pipe duct in which the supply pipe rises to the bathroom, and cold water storage cistern. The appropriate action to rectify this problem is to
Signup and view all the answers
Water Regulations do not permit the fixing of rigid screw-in type silencer tubes to float valves, because such devices
Water Regulations do not permit the fixing of rigid screw-in type silencer tubes to float valves, because such devices
Signup and view all the answers
The amount of noise being caused by a float valve in a storage cistern can be reduced by
The amount of noise being caused by a float valve in a storage cistern can be reduced by
Signup and view all the answers
The renewal of a section of copper pipework to a washbasin has to be left overnight for completion the next day. Which one of the following precautions should be taken in addition to closing the service valves to the wash basin?
The renewal of a section of copper pipework to a washbasin has to be left overnight for completion the next day. Which one of the following precautions should be taken in addition to closing the service valves to the wash basin?
Signup and view all the answers
When renewing a cold feed and expansion cistern to an Indirect Domestic Hot Water System, the isolating valve to the cistern must be closed, and the
When renewing a cold feed and expansion cistern to an Indirect Domestic Hot Water System, the isolating valve to the cistern must be closed, and the
Signup and view all the answers
Before removing a section of copper pipework for maintenance purposes, all necessary controls must be closed, appropriate sections of pipework must be drained and
Before removing a section of copper pipework for maintenance purposes, all necessary controls must be closed, appropriate sections of pipework must be drained and
Signup and view all the answers
Study Notes
Cold Water Mock 1
- Minimum Headroom: Details for minimum headroom above a cold water storage cistern for maintenance are found in the: Installation plan, Construction Regulations, Job specification, or Water Regulations Guide.
- Cold Water Service Pipe Diameter: The minimum diameter for an incoming cold water service pipe to a dwelling is 28 mm.
- Water Flow Rate Conversion: A water flow rate of 6 litres per minute is equivalent to 0.1 litres per second.
- Unapproved Installation Materials: Push-fit copper fittings, Solder fittings with lead/tin solder, are approved for use in Cold Water Systems installation, but Type 'A' compression fittings are not.
- Cold Water System Types: A "Direct Cold Water System" is where all cold water draw-off points, except the sink, are fed from a storage cistern. An alternative is an "Indirect System".
- Cold Water Service Pipe Depth: A cold water service pipe to a dwelling should be laid between 750 mm and 1350 mm below ground level.
Additional Cold Water Mock 1 Information
- Plastic Cold Water Storage Cisterns: For cisterns with capacities less than 1000 litres, a common warning/overflow pipe should be used.
- Cold Water Supply Stop Valve Placement: The servicing valve, automatic air release, should be placed immediately above the stop valve.
- Underground Copper Pipe Connections: Type A (non-manipulative compression fittings), Integral solder ring capillary fittings, and Endfeed solder capillary fittings are acceptable for underground service pipe connections. Type B (manipulative compression fitting) is not.
- Cold Water Storage Cistern Connections: The vent pipe, distribution pipe, and cold feed pipe should be connected to the cistern, but not the overflow/warning pipe.
- Cold Water System Component Connections: Plastic jointing washers, Lead free solder, and Non-manipulative compression fittings are acceptable for connections between systems and cisterns. Oil based jointing compounds are not.
- Soundness Test Periods: Accessible copper cold water supply pipes must be tested for one hour at 1.5 times the working pressure.
- Plumbing System Sound Test Requirements: Hydraulic test is required for cold water systems.
Further Information
- Cold Water Storage Cistern/Direct/Indirect system Connections: When the cylinder cold feed and cold distribution are connected to the same cold water storage cistern, the two pipes must be connected on opposite sides of the cistern.
- Cold Water System Maintenance: When removing an appliance from a cold water system, the customer and other trades should be advised before disabling the hot water supply.
- Cold Water Electrical Supply and Maintenance: The electrical supply to the hot water heater must be isolated before work can be carried out.
- Temporary Cold Water Supply Requirements: Electrical (or other) trades may require a temporary cold water supply when the main supply is isolated for maintenance.
- Pipework Maintenance: A plumber should seek supervision or advice and guidance when they cannot rectify a fault in the cold water system component.
- Cold Water Storage Cistern Capacity: For WC cisterns less than 2000 liters, a warning/overflow pipe should be used.
- Cold Water Pipework Installation: Removing all flux from soldered pipe fittings before installation, ensuring that fittings are used instead of pipe bends, pipework is fixed properly are recommended for reducing noise in copper pipework.
- Cold water leak resolution: A suspected leak in a pipe should be inspected for causes like ruptures, corrosion from cleaning products, or air inside the water.
- Pipework Maintenance/Renewal: A section of copper pipework should be drained; and temporary earth continuity bonding should be considered.
- Cold Water System Maintenance/Temporary Shutdown/Notifications: When a cold water system is undergoing maintenance, a warning sign should be placed.