Analytical Chemistry: Dynamic Range and Detection Limits

WellRegardedFairy avatar
WellRegardedFairy
·
·
Download

Start Quiz

Study Flashcards

27 Questions

What method is most suitable to minimize matrix effects when analyzing the caffeine content of carbonated drinks using spectrophotometry?

MSA

What does the factor $V_{f}$ account for in the context of the text?

Dilution of the sample

Which equation represents a linear plot when Sspike is plotted against Vs?

$y = mx + b$

In MSA, what does spiking involve?

Addition of standard solution to sample aliquots

How can Cx be calculated in the intercept method?

$kCx Vx Vf$

What happens to resulting solutions in MSA when spiking is used with an adequate amount of sample available?

They are diluted to identical volumes

What is the dynamic range in analytical chemistry?

The range of concentrations from LOD to LOQ

In the context of the phenanthroline method, what does 'S' represent in the calibration curve equation?

Measured absorbance

What does the LOD stand for in analytical chemistry?

Limit of Detection

How is LOD related to LOQ in an analytical method?

LOD is lower than LOQ

What is the purpose of a calibration sensitivity in analytical chemistry?

To establish linearity in calibration curves

What is the key principle emphasized in the text regarding Analytical Chemistry?

Extrapolation is a mortal sin in Analytical Chemistry

What is the equation of the line of best fit shown in the calibration curve?

y = 0.0382x + 0.2412

What is the value of the slope, m, from the equation of the line of best fit?

0.0382

What is the value of the y-intercept, b, from the equation of the line of best fit?

0.2412

What is the concentration of iron, Cx, in the sample calculated using the calibration curve?

$7.01 \text{ ppm Fe}$

What is the purpose of using an internal standard method (ISM) in chromatography?

To improve the accuracy of quantitative analysis

In a one-point ISM, what does the constant of proportionality (F) represent?

The response factor relating analyte and internal standard signals

In a multiple-point ISM, what is plotted to obtain the calibration curve?

Ratio of analyte signal to internal standard signal (Sx/SIs) vs. analyte concentration (Cx)

In the sample problem, what is the value of the proportionality constant (F) calculated?

0.9612

What is the final concentration of the analyte in the unknown sample, as calculated in the sample problem?

$5.77 \times 10^{-3}$ M

Which equation is used in the one-point internal standard method?

$S_x C_x = F S_{Is} C_{Is}$

What is the purpose of plotting the instrument signal against the actual concentration of the standard?

To determine the concentration of the unknown sample

What is the relationship between the instrument signal (b) and the concentration of the standard (Cs) for a given volume (Vx) and final volume (Vf)?

b = kCsVx/Vf

What is the concentration of the Fe3+ ion in the water sample, given the following information: Cs = 11.1 ppm, Vx = 10.00 mL, Vf = 50.00 mL, and instrument signal = 1.009?

11.1 ppm

What is the purpose of the 'word of caution' section in the given text?

To warn against correcting for the signal of the standard solution

In the given data, what is the instrument signal corresponding to a standard concentration of 5.55 ppm?

0.437

Study Notes

Spectrophotometric Analysis of Caffeine in Carbonated Drinks

  • In the analysis of caffeine content in carbonated drinks using spectrophotometry, the matrix effect can be significant due to the complexity of the drink's matrix compared to the matrix of the caffeine standard.
  • To minimize matrix effects, the Method of Standard Additions (MSA) is the most suitable method to use.

Method of Standard Additions (MSA)

  • MSA involves the addition of one or more increments of standard solution to a fixed volume of sample aliquots, followed by dilution to identical volumes prior to measurement.
  • There are two ways to perform MSA, depending on the amount of sample available:
    • Spiking: involves the addition of one or more increments of standard solution to fixed volume of sample aliquots.
    • Standard addition: involves the successive addition of increments of standard solutions to a single measured volume of the sample.

Calculating Concentration using MSA

  • The instrument signal (S) can be plotted against the volume of standard solution added (Vs), resulting in a linear plot of the form y = mx + b.
  • The concentration of the sample (Cx) can be calculated using the ratio of the instrument signal with and without the added standard.
  • Cx can be calculated either by direct calculation method or the intercept method (also known as b/m extrapolation).

Dynamic Range

  • The dynamic range, also known as the working range or calibration range, is the interval at which a certain method provides results with acceptable uncertainty.
  • It ranges from the limit of quantitation (LOQ) to the point at which a certain calibration curve departs from linearity (also known as the Limit of Linearity or LOL).

Quantitation and Detection Limits

  • The limit of quantitation (LOQ) is the lowest concentration of an analyte that can be quantitated with acceptable uncertainty.
  • The detection limit is the lowest concentration of an analyte that can be detected with acceptable uncertainty.

Internal Standard Method (ISM)

  • ISM involves the use of an internal standard to correct for variations in the signal of the chromatographic system and variations in the exact volume of sample or sample extract introduced into the chromatographic system.
  • ISM can be performed in one-point and multiple-point calibration methods.

One-Point Internal Standard Method

  • The concentration of the analyte in the unknown sample (Cx) can be calculated using the ratio of the analyte signal to the internal standard signal (Rx).
  • The proportionality constant (F) can be calculated using the internal standard signal (SIS) and the concentration of the internal standard (CIS).

Word of Caution!

  • In ESM, it is a common practice to correct the signal of standard solution with no added sample (or the blank).
  • In MSA, NEVER correct for the signal obtained in the flask with no sample. That signal is due to the added standard solution!

This study guide covers the concept of dynamic range in analytical chemistry, with a focus on detection limits and calibration ranges. It references Kaiser's paper on the acceptable value of k in calculating detection limits and Skoog's Quantitative Chemical Analysis (8th ed.) for derivation of simplified formulas.