Diagrams Configuration PDF

Document Details

FasterNephrite1826

Uploaded by FasterNephrite1826

Tags

power monitoring electrical diagrams vista software industrial training

Summary

This document provides training material on how to configure diagrams for Schneider Electric's EcoStruxureTM Power Monitoring Expert software. It covers topics such as creating homepage diagrams, one-line diagrams, and linking diagram objects.

Full Transcript

Diagrams Configuration EcoStruxureTM Power Monitoring Expert Digital Power Global Training Confidential Property of Schneider Electric Internal Chapter Objective: By the end of this chapter, you will be able to understand: 1. Create a homepage diag...

Diagrams Configuration EcoStruxureTM Power Monitoring Expert Digital Power Global Training Confidential Property of Schneider Electric Internal Chapter Objective: By the end of this chapter, you will be able to understand: 1. Create a homepage diagram in Vista that displays high-level site information. 2. Create a one-line diagram for the facility’s electrical distribution in Vista that displays operational values. 3. Create diagram objects that link to the default diagrams of the devices in Management Console. Internal Agenda 01 02 03 04 Graphic Screen Vista Creating custom user Key Points to Application diagrams Remember Internal Graphic Screen Applications Diagrams Web Application Open the Diagrams application from the Diagrams link in the Web Applications banner Use the Diagrams application to view historical and real- time data in one-line and graphics diagrams Confidential Property of Schneider Electric | Page 5 Internal Device Diagrams Display a device type specific diagram for each device that is configured in the system. Devices diagrams are created automatically. The device type specific diagrams are the same as the ones used in the default Vista network diagram. Cannot add, edit, share, or delete Devices diagrams Confidential Property of Schneider Electric | Page 6 Internal Diagram Library Access all the diagrams that you can view in the Diagrams application Add diagrams to the library, edit them, share them, or delete them. Can be listed individually or they can be organized within folders. Users can set a diagram to be their own personal default, or the default for the system. Devices diagram folder is a system folder that is automatically generated. It can not be edited or deleted. Network diagram is automatically added to the library when it is generated in Vista. Use the Diagram Library to select the diagram you want to view. Confidential Property of Schneider Electric | Page 7 Internal Network Diagram Before you can view the Network Diagram in the Diagrams application, you must generate a network diagram (network.dgm) in Vista. The network diagram is automatically added to the Diagram Library. It is the homepage for The Vista component is installed with Power Monitoring Expert on a primary server or Diagrams. Engineering Client. The Diagrams application uses the network diagram generated in Vista for display in the browser. It is saved here: C:/Program Files (x86)/Schneider Electric/Power Monitoring Expert/config/diagrams/ud/ Confidential Property of Schneider Electric | Page 8 Internal Vista Vista interface Vista is the PME component that displays and controls your power monitoring system A. Menu bar B. Toolbar C. Workspace D. Click a tab to display its data E. Click to return to the Network Diagram view F. Status bar G. Click this grouping object to open another window containing more data H. Toolbox I. Receive/Transmit Status indicators Image illustrates the Vista interface with a user diagram showing real-time values. Confidential Property of Schneider Electric | Page 10 Internal Vista interface Toolbar The toolbar offers quick access to the commands that are used most frequently A. Open G. Cut B. Save H. Copy A B C D E F G H I J K L C. Zoom I. Paste D. Fit to window J. Layout E. Restore to 100% K. Up One Level F. Plot selected Data L. Help Each command on the toolbar is also available from the menus. Click here to know more on Vista from PME System Guide for other display features through the menu option. Confidential Property of Schneider Electric | Page 11 Internal Default user diagrams Vista provides a set of pre-configured user diagrams that you can use to display data Generating, opening and closing a user diagram A user diagram is identified by its “.dgm” extension. Generate, open, and close user diagrams as needed. Generating a network diagram The network diagram displays your entire power monitoring system by linking to individual default user diagrams that display data from each device in your system. When you generate a network diagram, Vista automatically locates all devices in your system and displays them. This diagram is saved with the default name “network.dgm”. Confidential Property of Schneider Electric | Page 12 Internal Exercise – 25 Generate a Network Diagram Duration: 5 mins Page: 56 of Student Workbook Confidential Property of Schneider Electric | Page 13 Creating custom user diagrams Creating custom user diagrams Create a custom user diagram for the Diagrams application with Vista 1. Determine the primary display resolution. 2. Open Vista and create a new diagram using the Vista tools to create display objects and embedded graphics. 3. Save the diagram to...\Power Monitoring Expert\config\diagrams\ud or any subfolder in this location. 4. Add the custom diagram to the Diagram Library in the Diagrams web application. The main element of a Vista diagram is the background image. Confidential Property of Schneider Electric | Page 15 Internal Background Images The main element of a Vista diagram is the background image. It should be designed to incorporate as many elements of the diagram as possible, including: Main display area Pictures / logos / maps Electrical one-lines Must be saved as:.bmp,.jpg,.png,.gif,.emf,.wmf, or.avi Confidential Property of Schneider Electric | Page 16 Internal Editing a user diagram Display Mode vs. Edit Mode Display mode if the Toolbox is closed Edit mode if the Toolbox is open Allows any user to monitor the system and Allows a supervisor to configure the appearance and function of user diagrams view system data. and objects Single-click objects to view the information Double-click objects to view the information they contain or perform their associated they contain or perform their associated action. action. Controller access or higher can control some Right-click on objects to view configuration aspects of the system options Note: To edit a user diagram, the Diagram Objects toolbox must be displayed. Note: To open the toolbox, select Options > Show Toolbox. Confidential Property of Schneider Electric | Page 17 Internal Toolbox There are seven types of diagram objects available on the Diagram Objects toolbox Grouping Object: Group a number of related objects within a separate grouping window. Diagram objects provide Text Box: Display independent headings, titles, and comments in a user diagram. the interface to ION registers in your network. Numeric Object: Display real-time numeric values such as Volts, Amps or kW. Each diagram object performs a single function. Status Object: Display Boolean data (On/Off, Yes/No, 1/0, etc.) or device-dependent conditions to To add a function to a user indicate the status of a digital output (relay), digital input (status input) or setpoint. diagram, choose the type of diagram object you want, Data Log Viewer: Display data logs stored in the ION_Data database, show waveform data and trends drag it into the user using tables, and provide data for plotting. diagram then link it to the appropriate register in a Event Log Viewer: Display event logs stored in the ION_Data database, show event records from devices and other components, and display alarms. node Control Object: Send commands to a device on your network (for example, clear an energy accumulator, toggle a relay, reset a counter, or adjust the value of an analog output device). Confidential Property of Schneider Electric | Page 18 Internal Vista editing functionality Vista has limited drawing functionality. When working in Vista, keep in mind the following: There is no graphic rotate/flip option in Vista. The ordering of objects is limited to "Send to back". The use of text boxes and grouped objects in close proximity will affect navigation in some instances. An object's (for example, Numeric, Grouping, and so on) reference point is its upper left corner. It is recommended to use dedicated graphic editing tools to create the background images. CAD, Visio, MS Paint, Etc. Confidential Property of Schneider Electric | Page 19 Internal Linking a diagram object to a data source After placing an object in your user diagram link the object to a data source. Some diagram objects require a real-time data source and others require a logged data source Confidential Property of Schneider Electric | Page 20 Internal Graphic Components PME has many graphics and templates for use in diagram creation: ANSI and IEC symbols Background templates (for example, 1024x768, 1280x720, 1440x900 …) Menu images and icons Power meter and device icons Generic icons Equipment images Confidential Property of Schneider Electric | Page 21 Internal How to create… a Vista Diagram? Confidential Property of Schneider Electric | Page 22 Demonstration Internal Exercise – 26 Build a Homepage for Vista and Diagrams Duration: 20 mins Page: 57 of Student Workbook Confidential Property of Schneider Electric | Page 23 Exercise – 27 Build an Electrical One-Line Diagram Duration: 15 mins Page: 60 of Student Workbook Confidential Property of Schneider Electric | Page 24 Exercise – 28 Add Diagrams to Diagrams Web Applications Library Duration: 10 mins Page: 63 of Student Workbook Confidential Property of Schneider Electric | Page 25 RECAP Internal Key Points to Remember Graphics screens are designed and configured in Vista. Both Vista and Diagrams are used to navigate and "use" the graphic screens. Vista comes with default meter diagrams for all devices. Custom diagrams can be designed to link to each other, and to the default meter diagrams. Confidential Property of Schneider Electric | Page 27 Internal © 2021 Schneider Electric. All Rights Reserved. Schneider Electric and Life Is On Schneider Electric are trademarks and the property of Schneider Electric, its subsidiaries, and affiliated companies. Internal Total Load: Energy Usage: Natural Gas: Water: Voltage: Power Factor: Internal Confidential Property of Schneider Electric | Page 30 Internal Main_XFMR 12kV – 400V Main_BKR 1250A HVAC_1 HVAC_2 Light_1 Light_2 Light_3 Proc_1 Proc_2 Proc_3 100A 100A 100A 100A 100A 160A 160A 200A Confidential Property of Schneider Electric | Page 31 Internal

Use Quizgecko on...
Browser
Browser