GLA-TR-150 Steinel Power Pack PDF

Summary

This document provides technical specifications and wiring diagrams for the GLA-TR-150 power pack from Steinel, a low-voltage power supply. It details voltage, current, and output parameters, alongside connectivity options and installation guidance.

Full Transcript

GLA-TR-150 by Steinel Power Pack Item No. 63205 Voltage 120/230/277 VAC, 50/60 Hz...

GLA-TR-150 by Steinel Power Pack Item No. 63205 Voltage 120/230/277 VAC, 50/60 Hz Output 24 VDC +/- 5% 250 mA (class 2) Load 20 A @ 120/230/277 VAC 50/60 Hz - ballast and incandescent load 1 hp @ 120-240 VAC, 50/60 Hz 15 A @120 VAC, 50/60 Hz - receptacle load Isolated Relay Single pole, double-throw with NO, NC and common outputs; rated 1 A @ 30 VAC/VDC Environment IP20 rated, -4°F to +130°F, -20°C to +55°C Dimensions 3.2 x 2.4 x 1.5 in (LxWxD) 81 x 60 x 39 mm Threaded Nipple.83 x.83 in Dimensions 21 x 21 mm Warranty 5 years Certifications C-UL-US Listed, RoHS Compliant, UL 2043 Plenum Rated The TR 150 is a full featured power pack with an isolated Key Features: relay that provides power to STEINEL low voltage occupancy sensors and other control devides. They are Class 2 output Convenient mode switch selects either manual ON or power supplies, suitable for parallel interconnection. automatic ON operation LED status indicator The power packs switch the load(s) ON and OFF in response Built-in isolated relay for use with HVAC controls and to signals from the control devices. Each power pack other low voltage devices contains a Mode Switch to select either manual ON or Force on and force off control inputs allow for integration automatic ON operation. In manual ON mode, occupants with a building automation system for time of day control operate a low voltage momentary switch to turn lights ON. or load shed applications. Switching is performed at, or close to, the zero-cross of All wires have UL Style 1659, 250°C, 600V insulation: the AC waveform in order to improve relay performance 18 AWG: Black for Line and White for Neutral 1/2 inch threaded nipple and two lock nuts are used to 12 AWG: two Red wires for normally open dry contact secure to a standard 1/2” knockout from the 20A relay Low voltage momentary switch input allows for manual 22 AWG: 9 low voltage conductors: Red (+24VDC), control in automatic or manual mode Black (-24 VDC), Blue (Control Input), Orange ( Force Switching Power Supply provides up to 250mA of 24VDC On), Brown (Force Off), Gray (Momentary Switch Input), to low voltage controls Yellow (Isolated Relay Common), Yellow with Red Stripes 15 A receptical load control rated (Normally Open Isolated Relay), Yellow with Black Stripes (Normally Closed Isolated Relay) Voltage UL 2043 Plenum Rated IP 20 Rated Load Isolated Relay GLA-TR-150 by Steinel Power Pack Wiring Low NEUTRAL Voltage 3-Way Wiring LOAD NEUTRAL NEUTRAL LOAD LOAD LINE VOLTAGE HOT SWITCH WHITE (NEUTRAL) HOT HOT 24VDC BLACK (HOT) RED (RELAY) RED (RELAY) Occupancy WHITE (NEUTRAL) Sensor WHITE (NEUTRAL) 24VDC BLACK (HOT) RED (RELAY) RED (RELAY) BLACK (HOT) 24VDC RED (RELAY) RED (RELAY) Occupancy BLUE (CONTROL) BLACK (-24VDC) Sensor Sensor RED (+24VDC) BLUE (CONTROL) BLACK (-24VDC) BLUE (CONTROL) RED (+24VDC) BLACK (-24VDC) RED (+24VDC) BLUE (CONTROL) BLACK (-24VDC) Model# RED (+24VDC) TR150 BLUE (CONTROL) BLUE (CONTROL) BLACK (-24VDC) Power Pack BLACK (-24VDC) GRAY (MOMENTARY SWITCH) Model# RED (+24VDC) Model# RED (+24VDC) TR150 GRAY (MOMENTARY SWITCH) Isolated Relay TR150 YELLOW/RED (NORMALLY OPEN) Power Pack YELLOW/RED (NORMALLY OPEN) NORMALLY OPEN Power Pack GRAY (MOMENTARY SWITCH) YELLOW (RELAY COMMON) YELLOW (RELAY COMMON) RELAY COMMON YELLOW/BLACK (NORMALLY CLOSED) NORMALLY CLOSED YELLOW/BLACK (NORMALLY CLOSED) YELLOW/RED (NORMALLY OPEN) ORANGE (OVERRIDE ON) ORANGE (OVERRIDE ON) BROWN (OVERRIDE OFF) BROWN YELLOW (RELAY (OVERRIDE OFF) COMMON) YELLOW/BLACK (NORMALLY CLOSED) Symbol List ORANGE (OVERRIDE ON) BROWN (OVERRIDE OFF) Normally open momentary contact switch Symbol List Symbol List Normally open momentary contact switch Line Voltage 3-Way Normally open Wiring momentary contact switch Maintained contact switch Building Management System NEUTRAL LOAD Two Stage Multi Level 3-Way Switching NEUTRAL LOAD Load 1 - Auto ON by sensor/ Auto OFF by sensor or switch HOT Traveler NEUTRAL Wires LOAD 1 WHITE (NEUTRAL) 3-Way 3-Way HOT BLACK (HOT) Traveler 24VDC RED (RELAY) RED (RELAY) Switch Switch WHITE (NEUTRAL) Wires Occupancy HOT BLACK (HOT) 3-Way 3-Way Sensor RED (RELAY) 24VDC RED (RELAY) WHITE (NEUTRAL) 24VDC 24VDC Switch Switch Occupancy Occupancy Occupancy BLUE (CONTROL) BLACK (-24VDC) BLACK (HOT) RED (RELAY) RED (RELAY) RED (+24VDC) Sensor Sensor Sensor BLUE (CONTROL) BLACK (-24VDC) RED (+24VDC) BLUE (CONTROL) BLUE (CONTROL) BLACK (-24VDC) BLACK (-24VDC) BLUE (CONTROL) RED (+24VDC) RED (+24VDC) BLACK (-24VDC) Model# RED (+24VDC) BLUE (CONTROL) TR150 BLUE (CONTROL) GRAY (MOMENTARY SWITCH) BLACK (-24VDC) Power Pack BLACK(NORMALLY YELLOW/RED (-24VDC) OPEN) Model# RED (+24VDC) Model# YELLOWRED (+24VDC) (RELAY COMMON) TR150 TR150 GRAY (MOMENTARY YELLOW/BLACK (NORMALLY SWITCH) CLOSED) Power Pack GRAY (MOMENTARY SWITCH) Power Pack ORANGEYELLOW/RED (NORMALLY OPEN) (OVERRIDE ON) YELLOW/RED (NORMALLY OPEN) BROWN YELLOW (RELAY (OVERRIDE OFF) COMMON) YELLOW (RELAY COMMON) YELLOW/BLACK (NORMALLY CLOSED) YELLOW/BLACK (NORMALLY CLOSED) ORANGE (OVERRIDE ON) ORANGE (OVERRIDE ON) BROWN (OVERRIDE OFF) BROWN (OVERRIDE OFF) Load 2 - Manual ON only by switch/ Auto OFF by sensor or switch Product Overview & Mounting NEUTRAL LOAD 2 HOT The TR 150 power pack WHITE (NEUTRAL) Line voltage mounts to a junction box BLACK (HOT) RED (RELAY) RED (RELAY) wires with 1/2 inch knockouts. BLUE (CONTROL) Model# BLACK (-24VDC) RED (+24VDC) Two lock nuts TR150 Power Pack GRAY (MOMENTARY SWITCH) YELLOW/RED (NORMALLY OPEN) 1/2 inch YELLOW (RELAY COMMON) YELLOW/BLACK (NORMALLY CLOSED) threaded chase ORANGE (OVERRIDE ON) BROWN (OVERRIDE OFF) nipples Upon occupancy, lights (Load 1) attached to Power Pack (set to Low voltage Auto ON) will illuminate automatically while lights (Load 2) attached wires Model# TR 150 TR100 to Power Pack (set to Manual ON) require the occupant to turn the Power Pack lights on manually by means of a low voltage switch. All lights can LED status be turned off manually by a low voltage switch or automatically by Manual/automatic indicator an occupancy sensor(s). mode switch www.crestron.com 800.237.2041 M-03201-1

Use Quizgecko on...
Browser
Browser