LEC2_CEBDLG20_NATIONAL BUILDING CODE PDF

Summary

This document provides an overview of the National Building Code of the Philippines (NBCP) and relevant building regulations. It covers topics like building codes, regulations for building design and construction, and different types of housing.

Full Transcript

Codes and Regulations for Building Design and Construction Building Systems Design Objectives 1. Understand the key codes and regulations governing construction and design. 2. Explore specific requirements for various building types: houses, schools, and commercial...

Codes and Regulations for Building Design and Construction Building Systems Design Objectives 1. Understand the key codes and regulations governing construction and design. 2. Explore specific requirements for various building types: houses, schools, and commercial buildings. 3. Learn about compliance to ensure safety, functionality, and legal standards. Part I: General Building Regulations National Building Code of the Philippines (NBCP) Purpose: To ensure safety, health, and welfare in construction. Covers planning, design, occupancy, and maintenance of structures. Key Areas: Dimensions and sizes. Load-bearing standards. Accessibility requirements. Key Sections of the NBCP 1. Architectural Standards: Room sizes, heights, and ventilation. 2. Structural Design: Wind, earthquake, and load requirements. 3. Fire Safety Provisions: Fire-resistant materials, exits, and sprinklers. 4. Sanitation Standards: Plumbing, drainage, and water supply. 5. Accessibility: Ramps, elevators, and pathways for persons with disabilities (RA 7277). Socialized Economic and Open Housing Types The difference between socialized, economic, and open market housing lies in their target market, affordability, lot and building sizes, and government regulations. These housing classifications are defined by the Housing and Land Use Regulatory Board (HLURB) in the Philippines to cater to various income levels of the population. Here's a detailed comparison: Socialized, Economic and Open Housing Types 1. Socialized Housing Target Market: Low-income earners or informal settlers who cannot afford regular housing. Affordability: Maximum price cap is PHP 580,000 (as of recent updates; subject to change based on housing policies). Lot Size: Minimum lot area of 64 sqm. Floor Area: Minimum floor area of 18 sqm. Features: Basic amenities like electricity, water supply, and sanitation facilities. Simplified design and construction to lower costs. Government Support: Often supported by subsidies or incentives for developers, such as tax breaks. Socialized Economic and Open Housing Types 2. Economic Housing Target Market: Middle-income earners who can afford more than socialized housing but still need affordable options. Affordability: Price range from PHP 580,000 to PHP 1,700,000 (varies with updates). Lot Size: Minimum lot area of 72 sqm. Floor Area: Minimum floor area of 22 sqm. Features: Better design and materials compared to socialized housing. Includes additional amenities, such as recreational spaces or parks in larger developments. Government Support: May qualify for incentives under specific programs but with less emphasis compared to socialized housing. Socialized, Economic and Open Housing Types 3. Open Market Housing Target Market: Upper-middle to high-income earners who can afford premium housing options. Affordability: No price ceiling; typically, above PHP 1,700,000. Lot Size: Minimum lot area of 120 sqm. Floor Area: Minimum floor area of 36 sqm. Features: High-quality materials, modern designs, and access to premium amenities (e.g., clubhouses, pools). Located in desirable areas with better infrastructure. Government Support: Does not receive subsidies or incentives. Socialized, Economic and Open Housing Types Category Socialized Housing Economic Housing Open Market Housing Target Market Low-income earners Middle-income earners High-income earners Price Up to PHP 580,000 PHP 580,000–1,700,000 PHP 1,700,000 and above Lot Size Min. 64 sqm Min. 72 sqm Min. 120 sqm Floor Area Min. 18 sqm Min. 22 sqm Min. 36 sqm Amenities Basic utilities Basic + recreational Premium amenities Gov't Support High Moderate None Part I: Room Standards Residential Houses/Buildings Minimum Room Sizes: Bedrooms: Minimum floor area of 6 sqm (for single occupancy). Living Rooms: Minimum of 12 sqm. Kitchen: Minimum of 3 sqm. Bathrooms: Minimum of 1.2 sqm. Windows: Total window area must be at least 10% of the floor area of the room. Ventilation and Lighting: Natural ventilation or artificial mechanical systems must be provided. Part I: Room Standards Residential Houses/Buildings Minimum Room Sizes: Habitable Rooms: 6 square meters with a minimum dimension of 2 meters Living Rooms: Minimum of 12 sqm. Kitchen: 3 square meters with a minimum dimension of 1.5 meters Bathrooms: 1.2 square meters with a minimum dimension of 0.9 meters Windows: Total window area must be at least 10% of the floor area of the room. Ventilation and Lighting: Natural ventilation or artificial mechanical systems must be provided. Office Buildings Small Offices/Rooms: Minimum floor area of 5–7 sqm per workstation for ergonomic movement. Conference Rooms: Typically, 2–2.5 sqm Room per person, depending on occupancy. Standards Pantry/Break Rooms: Recommended floor area of 10–15 sqm, accommodating seating and appliances. Toilets: Minimum size of 1.2 sqm per cubicle. Male and female toilets must be provided on each floor. Room Standards Commercial Buildings Shops/Stores: Sales areas must have a minimum of 1.8 sqm per person for circulation. Storage Rooms: Minimum floor area based on the type of business, typically 10–15 sqm or more. Bathrooms: Minimum size of 1.5 sqm per cubicle. Must comply with accessibility standards under BP 344. Room Standards School Buildings Classrooms: Department of Education (DepEd) - DepEd provides standards for public elementary and high schools. Typically: Minimum floor area for a classroom is 7m x 9m (63 sqm), accommodating 40–50 students. Commission on Higher Education (CHED) - For higher education facilities, CHED sets guidelines depending on the type of institution but does not directly mention classroom sizes in the NBCP. Libraries: Minimum of 4 sqm per user, with additional space for shelves and furniture. Bathrooms: At least 1 toilet per 25 students (or as mandated by the DepEd). Bathrooms must be accessible and gender-segregated. Part II: Minimum Hallway Width School Buildings:1.8 meters (1.80 m) This ensures safe and efficient movement for students, teachers, and staff, and facilitates quick evacuation during emergencies. Hotels:1.5 meters (1.50 m) Designed for guest comfort and compliance with fire and safety regulations. Commercial Buildings:1.5 meters (1.50 m) For office areas or general commercial spaces, wider hallways (e.g., 2.0 m or more) may be required in high-traffic or public- facing spaces like malls. Residential Buildings:1.2 meters (1.20 m) Sufficient for standard household traffic and emergency evacuation in residential apartments and condominiums Hospitals (For comparison):2.4 meters (2.40 m) Areas where patients are transported on stretchers or wheelchairs. Ensures adequate clearance for medical emergencies. Part III: Setbacks Residential Houses/Buildings Single Detached Houses Front setback: Minimum 3 meters. Side setback: Minimum 2 meters. Rear setback: Minimum 2 meters. Townhouses Front setback: Minimum 2 meters. Rear setback: Minimum 2 meters. Side setback: None, as townhouses typically share side walls. Apartments/Condominiums Setbacks vary based on the number of floors: 1–2 floors: 3 meters (front), 2 meters (side and rear). 3+ floors: Consult zoning laws, as setbacks increase with height to ensure light and air circulation. Part III: Setbacks Office Buildings Front setback: Minimum 5 meters from the property line. Side and rear setbacks: Minimum 2–3 meters, depending on building height and local ordinances. Special Notes High-rise office buildings may require larger setbacks to accommodate fire escapes and ensure pedestrian safety. Part III: Setbacks Commercial Buildings Front setback: Minimum 5 meters, allowing for parking or pedestrian access. Side setback: 0 meters (if adjoining another commercial structure) or 2 meters (if adjacent to a residential property). Rear setback: Minimum 2 meters. Special Notes For mixed-use buildings, setbacks depend on the commercial and residential zoning requirements. School Buildings Front setback: Minimum 5 meters, ensuring sufficient space for drop-off/pick- up areas. Side setback: Minimum 2 meters. Part III: Rear setback: Minimum 3 meters. Setbacks Special Notes Additional open spaces (e.g., courtyards or playgrounds) may be required by local ordinances for safety and recreational use. Part IV: Minimum Ceiling Height School Buildings: 3.0 meters (3.00 m) for classrooms to ensure ventilation and thermal comfort. 2.4 meters (2.40 m) for administrative offices, corridors, and smaller spaces. Purpose: Provides sufficient airflow and a conducive environment for learning.Hotels:1.5 meters (1.50 m) Commercial Buildings: 2.7 meters (2.70 m) for spaces with high public traffic, such as retail stores, lobbies, and other common areas. 2.4 meters (2.40 m) for secondary areas, such as back offices or storage. Maximum Ceiling Height: No specific maximum, but design often considers energy efficiency and cooling requirements. Part IV: Minimum Ceiling Height Residential Houses/Buildings: 2.4 meters (2.40 m) for habitable rooms (e.g., bedrooms, living rooms). 2.1 meters (2.10 m) for mezzanines. Bathrooms: Standard minimum: 2.10 meters. Exception for sloping ceilings: 1.80 meters at the lowest point Purpose: Provides adequate ventilation and comfort for occupants. Office Buildings 2.7 meters (2.70 m) for open office areas, meeting rooms, and common spaces. 2.4 meters (2.40 m) for individual office spaces or workstations. Considerations: Ensures comfort and space for lighting and HVAC systems. Part IV: Minimum Ceiling Height Residential Houses/Buildings Window Openings/ Minimum Window Area: At least 10% of the floor area for habitable rooms (e.g., bedrooms, living rooms). At least 5% of the floor area for non-habitable rooms (e.g., kitchens, bathrooms). Ventilation Natural ventilation must be achieved through windows or openings, ensuring proper airflow. If natural ventilation is insufficient, mechanical ventilation (e.g., exhaust fans, air conditioning) must be provided. Cross-ventilation is encouraged by placing windows on opposite walls Part V: Windows and Ventilation Office Buildings Window Openings/Minimum Window Area: At least 10% of the floor area for office spaces requiring natural light and ventilation. Skylights or atriums can supplement lighting requirements. Ventilation Mechanical Ventilation or Air Conditioning: Offices often use centralized HVAC systems to maintain indoor air quality. Natural Ventilation: Used in small offices or supplementary to mechanical systems. Operable windows must provide airflow where applicable. Part V: Windows and Ventilation Commercial Buildings Window Openings/Minimum Window Area: At least 10% of the floor area for retail spaces, lobbies, and customer- facing areas. Warehouses or storage areas may not require windows but must have adequate ventilation. Ventilation Centralized HVAC systems are common in malls and large commercial spaces. Openings or vents are required in areas without air conditioning (e.g., parking spaces, storage areas). Exhaust systems must remove heat and pollutants in kitchens or similar environments. Part V: Windows and Ventilation School Buildings Window Openings/Minimum Window Area: At least 10% of the floor area for classrooms, laboratories, and libraries. Proper shading devices (e.g., blinds, overhangs) are encouraged to control glare. Ventilation Natural ventilation is prioritized for classrooms, with cross-ventilation provided through windows and vents. Ceiling or wall-mounted fans may supplement ventilation in tropical climates. Mechanical ventilation is required for enclosed spaces like auditoriums or computer rooms. Part VI: Fire Safety Requirements Fire Code of the Philippines (RA 9514) Key Requirements: Fire-resistant materials for structural elements. Adequate fire exits and escape routes. Installation of fire alarms and suppression systems. Inspection and Compliance: Regular inspections by the Bureau of Fire Protection (BFP). Compliance certificates prior to occupancy. Part VI: Fire Safety Requirements Automatic fire sprinkler systems are required in the following: 1. Based on Building Height: High-rise buildings (taller than 15 meters) are required to have AFSS, regardless of floor area or occupancy type. 2. Based on Floor Area: For low-rise commercial buildings, AFSS is required if the floor area exceeds 1,115 sqm. For warehouses, industrial facilities, and other high-risk structures, the threshold may vary depending on their specific fire hazard classification. Part VI: Fire Safety Requirements Automatic fire sprinkler systems are required in the following: 3. Based on Occupancy Type: Residential buildings like hotels, apartments, or dormitories accommodating more than 10 occupants must have AFSS, regardless of floor area. Hospitals, clinics, and nursing homes are required to install AFSS to protect occupants with limited mobility. Educational facilities with an occupancy of more than 50 people require AFSS. 4. Special Requirements for Specific Uses: Parking structures (multi-level or enclosed). Buildings or spaces used for high-hazard materials or processes. Part VI: Fire Safety Requirements AFSS may not be required for: Single-detached residential houses or low-occupancy structures. Small low-rise buildings with minimal fire hazards, provided alternative fire safety measures like fire extinguishers and smoke detectors are installed. Structures that meet the fire-resistive rating requirements of their construction type. Definition of Fire-Resistance Rating The fire-resistance rating is the period (in hours) a material or assembly can resist fire under standard testing conditions without failure in terms of structural integrity, insulation, or the passage of flames and gases. Materials or assemblies are tested as per standards like the Underwriters Laboratories (UL) tests or other internationally accepted methods. Definition of Fire-Resistance Rating Fire-Resistance Ratings for Different Components The NBCP categorizes fire-resistance ratings based on the type of construction and occupancy of the building. Below are the typical requirements: 1. Structural Components Columns, beams, and load-bearing walls: High-rise buildings: Minimum of 2 to 4 hours, depending on occupancy and building height. Low-rise buildings: Typically require a minimum of 1 hour. Floor assemblies: Residential and commercial buildings: Minimum of 1 to 2 hours. Industrial buildings: Often require higher ratings, up to 4 hours. Roof assemblies: Minimum of 1 hour, depending on occupancy and proximity to adjacent properties. Definition of Fire-Resistance Rating Firewalls and Party Walls Firewall – means a reinforced masonry or reinforced concrete separator with the appropriate fire-resistive rating and which shall be positioned between buildings/ structures to maintain the fire integrity of each building/ structure. Firewalls that are erected along and/or above property lines Party wall – means a wall jointly owned and jointly used by 2 parties under easement agreement or by right in law and erected at or upon a line separating 2 parcels of land each of which is, or is capable of being, a separate real-estate entity. Definition of Fire-Resistance Rating Fire-Resistance Ratings for Different Components 2. Firewalls and Party Walls Firewalls: Must have a fire-resistance rating of at least 2 to 4 hours, depending on the occupancy and separation requirements. Openings in firewalls: Limited and must be equipped with fire-rated doors or assemblies with at least 1.5 hours of resistance. 3. Staircases and Egress Components Enclosures for stairs: Require 1 to 2 hours of fire resistance to maintain a safe escape route. Corridors and exit passageways: Require a minimum rating of 1 hour. Definition of Fire-Resistance Rating Testing and Compliance The Bureau of Fire Protection (BFP) oversees compliance with fire- resistance requirements. Materials and assemblies must be certified to meet fire-resistance standards. Periodic inspections ensure that fire-resistive elements are maintained over time. Definition of Fire-Resistance Rating Occupancy-Based Fire Resistance Ratings Group A (Residential) Minimum fire-resistance rating for walls and floors is 1 hour. Firewalls separating residential units must be 2 hours. Group B (Educational) Fire-resistance rating for walls and floors must be 2 hours for higher-capacity schools. Egress routes and stair enclosures require 1-hour fire resistance. Group C (Commercial) Structural elements in high-rise buildings require a fire-resistance rating of 3 to 4 hours. Interior partitions may need a lower rating of 1 hour unless separating hazardous spaces. Part VI: Fire Safety Requirements Residential Houses/Buildings - Key Fire Safety Requirements Fire Exits: For single-family dwellings, fire exits are typically through doors and windows. Multi-family dwellings (e.g., apartments) must have at least two means of egress per floor. Fire Extinguishers: At least one portable fire extinguisher for every 10 units in apartments. Smoke Detectors and Alarms: Required for each floor and bedroom in residential buildings. Fire-Resistant Materials: Use of non-combustible or fire-retardant materials for walls, ceilings, and doors in critical areas like stairwells. Access for Fire Trucks: Sufficient open space around the building for firefighting operations. Part VI: Fire Safety Requirements Office Buildings - Key Fire Safety Requirements Fire Exits: At least two exits per floor. Exits must be clearly marked, illuminated, and free from obstructions. Automatic Fire Sprinkler Systems: Mandatory for buildings with a floor area exceeding 1,115 sqm or heights above 15 meters. Fire Alarms: Audible alarms connected to a centralized system. Emergency Lighting: Installed in hallways, stairwells, and exit routes to guide occupants during power outages. Evacuation Plans: Floor plans and fire evacuation routes must be displayed on each floor. Smoke Control Systems: Ensures smoke does not accumulate in corridors or stairwells. Part VI: Fire Safety Requirements Commercial Buildings - Key Fire Safety Requirements Fire Exits: Minimum of two fire exits per floor, depending on occupancy load. Fire exit doors must be fire-rated and equipped with panic hardware. Sprinkler Systems: Required for commercial spaces exceeding 930 sqm. Fire Detection and Alarm Systems (FDAS): Installed in all areas, especially high-risk zones like kitchens and storage rooms. Fire-Resistant Construction: Use of fire-resistant materials for walls, ceilings, and partitions in critical areas. Fire Hose Cabinets and Extinguishers: Located within 30 meters of any point in the building. Fire Drills: Regularly conducted to train employees and tenants on fire evacuation procedures. Part VI: Fire Safety Requirements School Buildings - Key Fire Safety Requirements: Fire Exits: Minimum of two fire exits per classroom for schools with high occupancy. Fire Alarms: Audible alarms installed in classrooms, hallways, and assembly areas. Sprinkler Systems: Required for multi-level school buildings or those with high occupancy loads. Evacuation Plans: Clearly marked and displayed in every classroom. Evacuation drills must be conducted periodically. Smoke Detectors: Installed in classrooms, laboratories, libraries, and dormitories. Emergency Lighting: Provided in corridors, stairwells, and assembly areas for safe evacuation. Part VII: Floor Loading Requirements Residential Houses/Buildings - Typical Floor Loading Reqmts: Living Areas: Minimum design load: 150 kg/sqm (kilograms per square meter). Bedrooms: Minimum design load: 120 kg/sqm. Balconies: Minimum design load: 200 kg/sqm to account for increased usage and gatherings. Special Considerations: Higher loads may apply for multi-family buildings or areas where heavy furniture/appliances are expected. Part VII: Floor Loading Requirements Office Buildings - Typical Floor Loading Requirements: General Office Areas: Minimum design load: 200–300 kg/sqm, depending on occupancy and equipment density. File Rooms/Storage Areas: Minimum design load: 500–1000 kg/sqm, depending on the weight of files, cabinets, and storage racks. Special Considerations Server rooms or areas housing heavy equipment may require loads exceeding 1000 kg/sqm. Part VII: Floor Loading Requirements Commercial Buildings - Typical Floor Loading Requirements: Retail Spaces (Light Loads): Minimum design load: 300–400 kg/sqm, suitable for small shops or boutiques. Department Stores/Heavy Retail Loads: Minimum design load: 500–750 kg/sqm to account for shelves and customer occupancy. Storage Areas: Minimum design load: 750–1000 kg/sqm or more for warehouses and stockrooms. Special Considerations Parking areas in commercial buildings require 250–300 kg/sqm, with allowances for vehicular movement and concentrated loads. Part VII: Floor Loading Requirements School Buildings - Typical Floor Loading Requirements: Classrooms: Minimum design load: 150–200 kg/sqm. Libraries: Minimum design load: 500 kg/sqm, considering the weight of books and shelves. Laboratories: Minimum design load: 300–500 kg/sqm, depending on the weight of equipment and furniture. Auditoriums/Gymnasiums: Minimum design load: 500–750 kg/sqm, accounting for assembly loads and event usage. Special Considerations Floors used for assemblies or gatherings require additional safety factors to account for dynamic loading. Part VII: Floor Loading Requirements General Considerations 1. Load Categories: Live loads: Temporary or movable loads (e.g., furniture, people). Dead loads: Permanent loads due to the building’s materials. 2. Safety Factors: Structural design incorporates safety margins for unforeseen loads. 3. Code Compliance: All designs must adhere to the NSCP for structural safety. Part VIII: Parking Requirements Residential Houses/Buildings Parking Requirements: Single Detached Houses: 1 parking slot per house (minimum slot size: 2.5 m x 5.0 m). Townhouses: 1 parking slot per unit, often integrated into the unit’s design. Apartment/Condominium Buildings: 1 parking slot per 8 units (for economic or socialized housing). 1 parking slot per 4 units (for open market housing or higher-end developments). Special Notes Additional slots may be required for visitors, depending on local ordinances. Part VIII: Parking Requirements Office Buildings Parking Requirements: General Office Buildings: 1 parking slot per 125 sqm of gross floor area (GFA). Mixed-Use Buildings (office with retail/other uses): Parking requirements are calculated based on the proportion of each use. Special Notes Parking areas must have designated spaces for persons with disabilities (PWD), complying with BP 344 (Accessibility Law). Part VIII: Parking Requirements Commercial Buildings Parking Requirements: Retail Stores, Restaurants, and Malls: 1 parking slot per 100 sqm of GFA for smaller commercial establishments. 1 parking slot per 50 sqm of GFA for larger malls and supermarkets. Hotels: 1 parking slot per 10 rooms, plus additional slots for staff and restaurant/event facilities. Special Notes Dedicated parking for delivery vehicles and loading/unloading zones is required. Part VIII: Parking Requirements School Buildings Parking Requirements: Basic Educational Institutions (e.g., primary and secondary schools): 1 parking slot per classroom. Higher Education Institutions (e.g., colleges, universities): 1 parking slot per 5 classrooms, plus additional spaces for administrative staff and visitors. Special Notes Schools must allocate areas for buses and service vehicles for safe student pick-up/drop-off. Part VIII: Parking Requirements General Considerations Minimum Parking Slot Dimensions: Standard: 2.5 m x 5.0 m. Parallel: 2.15 m x 6.0 m. PWD: 3.6 m x 5.0 m, located near building entrances. Local Ordinances: Requirements may vary depending on city or municipality. Always consult local regulations. Traffic Impact: Developers may be required to submit a traffic impact assessment for larger projects to ensure adequate parking and access. Part VIII: Parking Requirements General Considerations Minimum Parking Slot Dimensions: Standard: 2.5 m x 5.0 m. Parallel: 2.15 m x 6.0 m. PWD: 3.6 m x 5.0 m, located near building entrances. Local Ordinances: Requirements may vary depending on city or municipality. Always consult local regulations. Traffic Impact: Developers may be required to submit a traffic impact assessment for larger projects to ensure adequate parking and access. General Stairway Requirements (Based on NBCP) 1. Width of Stairs: Residential buildings: Minimum clear width of 0.75 m (750 mm). Commercial buildings: Minimum clear width of 1.10 m (1,100 mm). High-occupancy buildings: Wider stairs may be required based on the occupant load. 2. Rise and Run: Riser height: Maximum of 200 mm (20 cm). Tread depth: Minimum of 250 mm (25 cm). Uniformity in risers and treads is required throughout a flight of stairs. 3. Headroom Clearance: Minimum vertical clearance of 2.00 m (2,000 mm) above the stairs. General Stairway Requirements (Based on NBCP) 4. Handrails: Required on both sides for stairs wider than 1.10 m. Height: 0.80 m to 1.20 m (800 mm to 900 mm) measured from the nosing of the treads. Handrails must be continuous and easy to grip. 5. Landing Requirements: Required at the top and bottom of every stairway. Minimum depth: Equal to the width of the stairs. Stairs with more than 3.60 m in height must have an intermediate landing. General Stairway Requirements (Based on NBCP) 6. Number of Steps in a Flight: Maximum of 18 steps per flight. Minimum of 3 risers per flight. 7. Slope: The slope of stairs should not exceed a ratio of 1:2 (rise:run). For most standard staircases under the National Building Code of the Philippines (NBCP), the pitch range is 30 to 35 degrees, which corresponds to ratios like 1:1.5 or 1:1.75, depending on the design and space constraints. General Stairway Requirements (Based on NBCP) Additional Requirements for Specific Buildings 1. Fire Escape Stairs: Must be constructed of non-combustible materials. Single emergency exit stairway: Minimum 0.60 meters. Multiple emergency exit stairways: The width can be 1.20 meters or more, depending on occupancy load and the specific requirements based on building classification and usage. Must lead directly to a safe location (e.g., outdoors or a fire-resistance-rated corridor). 2. Spiral Stairs: Allowed in limited spaces or as secondary stairs. Minimum tread depth of 0.20 m at a point 300 mm from the center. Minimum clear width of 0.75 m (750 mm). General Stairway Requirements (Based on NBCP) General Stairway Requirements (Based on NBCP) 250 mm min. General Stairway Requirements (Based on Your text here NBCP) General Stairway Requirements (Based on NBCP) Additional Requirements for Specific Buildings 3. Accessibility: For public buildings, stairs must comply with BP 344 (Accessibility Law): Handrails with tactile markings. Warning strips or textured surfaces on top and bottom steps. General Stairway Requirements (Based on NBCP) Materials and Construction: Stairs must be constructed of durable and slip-resistant materials. Wooden stairs are permitted in residential buildings but not in fire escapes. Concrete or steel stairs are recommended for commercial and high-rise buildings. Building Height Limitations 1. Residential Buildings: BHL for single-family dwellings is generally up to 3 storeys (10–12 meters), depending on the local zoning regulations and structural design. 2. Commercial Buildings: Mid-rise commercial buildings: Up to 15 meters (5 storeys). High-rise commercial buildings: Subject to zoning ordinances and lot size but can exceed 15 meters, provided it adheres to structural, fire safety, and accessibility requirements. 3. Educational and School Buildings: Generally, up to 3–5 storeys (15–18 meters), depending on lot size and structural integrity. Building Height Limitations 4. Mixed-Use Developments: High-rise structures are permitted in specific zones; the height is regulated by the floor-to-area ratio (FAR) and setbacks. 5. Industrial Buildings: Typically ranges from 12–20 meters, depending on the type of facility and zoning rules. 6. Institutional Buildings (e.g., Hospitals): Limited to 5–10 storeys based on zoning and safety requirements. Factors Affecting Building Height Limitations 1. Zoning Ordinances: Each local government unit (LGU) has its own zoning ordinance which defines the BHL for specific zones, such as residential, commercial, or mixed-use areas. 2. Floor-to-Area Ratio (FAR): The FAR defines how much floor area can be built relative to the size of the lot. A higher FAR permits taller buildings. 3. Setbacks: Higher buildings require greater setbacks from property lines, as outlined in the NBCP. Factors Affecting Building Height Limitations Factors Affecting Building Height Limitations 4. Proximity to Airports (Civil Aviation Authority of the Philippines): The height of buildings near airports or aerodromes is strictly regulated. Structures must comply with the Obstacle Limitation Surfaces (OLS) to ensure airspace safety. 5. Fire Safety Requirements: High-rise buildings (those exceeding 15 meters) must have advanced fire protection systems as per the Fire Code of the Philippines. 6. Environmental Considerations: For environmentally sensitive zones, additional restrictions may apply. Sample BHL Guidelines from Zoning Ordinances Zone Maximum BHL Notes Low-Density Residential 10 meters (3 storeys) Includes single-detached homes. Medium-Density Residential 15 meters (5 storeys) Includes low-rise apartments. Smaller business Commercial (C1) 15–20 meters (5–7 storeys) establishments. Commercial (C2/C3) No fixed limit (subject to FAR) High-rise allowed with setbacks. Institutional 15–20 meters (5–7 storeys) Includes schools, hospitals, etc. Based on operations and zoning Industrial 12–20 meters rules. Sample BHL Guidelines from Zoning Ordinances Zone Maximum BHL Notes Low-Density Residential 10 meters (3 storeys) Includes single-detached homes. Medium-Density Residential 15 meters (5 storeys) Includes low-rise apartments. Smaller business Commercial (C1) 15–20 meters (5–7 storeys) establishments. Commercial (C2/C3) No fixed limit (subject to FAR) High-rise allowed with setbacks. Institutional 15–20 meters (5–7 storeys) Includes schools, hospitals, etc. Based on operations and zoning Industrial 12–20 meters rules. Floor Area Ratio The Floor Area Ratio (FAR) is a zoning regulation that determines the maximum allowable floor area of a building relative to the size of its lot. It is a critical parameter in urban planning, especially for regulating building height, density, and open space requirements. Total Building Floor Area 𝐹𝐴𝑅 = Lot Area How FAR (Floor Area Ratio) Works? FAR 1.0: The total floor area of the building is equal to the lot area. For example, on a 1,000 sqm lot, a building can have a total of 1,000 sqm of floor area. FAR 2.0: The building’s total floor area can be twice the lot area. On a 1,000 sqm lot, the building can have 2,000 sqm of total floor area. Higher FAR values allow for taller or more expansive buildings. Lower FAR values promote lower-density development with more open spaces. FAR in the Philippines In the Philippines, the FAR is determined by: 1. Zoning Ordinances of the local government unit (LGU). 2. Land Use Plans, which specify allowable densities and building sizes for different zones. For example: Residential Zones: Lower FARs (e.g., 1.0–2.0) to maintain low-density neighborhoods. Commercial Zones: Higher FARs (e.g., 5.0 and above) to allow for high- density developments. Mixed-Use Zones: FAR depends on the balance between residential, commercial, and open space requirements. Implications of FAR 1. Building Height: Higher FAR values often mean taller buildings, provided other regulations (like setbacks and maximum BHL) are followed. 2. Design Flexibility: Developers can choose whether to build taller buildings or spread the floor area across more of the lot. 3. Open Spaces: A higher FAR may reduce open spaces unless mitigated by setbacks or other zoning requirements. 4. Urban Density: Controls overcrowding in urban areas by balancing development intensity. Example of FAR Application Lot Area: 1,000 sqm. Zoning FAR: 3.0. Allowable Floor Area: 𝐴𝑙𝑙𝑜𝑤𝑎𝑏𝑙𝑒 𝐹𝑙𝑜𝑜𝑟 𝐴𝑟𝑒𝑎 = 𝐹𝐴𝑅 × 𝐿𝑜𝑡 𝐴𝑟𝑒𝑎 = 3.0 × 1,000 𝑠𝑞𝑚 = 3,000 𝑠𝑞𝑚. This 3,000 sqm can be distributed across multiple storeys or a single expansive floor, depending on the design and other building code restrictions. FAR is essential in balancing economic benefits for developers and maintaining liveable urban environments. If you need specific examples from a Philippine city or locality, let me know! General Door Size Requirements 1. Main Door (Residential) Minimum width: 900 mm (0.90 m) Minimum height: 2.0 m 2. Interior DoorsBedrooms: Minimum width of 700 mm (0.70 m) 3. Bathrooms/Toilets: Minimum width of 600 mm (0.60 m) 4. Doors for Public Buildings and Schools Minimum width: 1.20 m (Double-leaf doors can be used for wider openings) Minimum height: 2.0 m General Door Size Requirements 1. Doors for Accessible Spaces (Per BP 344 - Accessibility Law) Minimum clear width: 800 mm (0.80 m) Should accommodate persons with disabilities (PWDs), including wheelchairs. 2. Emergency Exits Minimum width: 900 mm (0.90 m) Should swing in the direction of egress and not obstruct hallways. 3. Doors for Commercial Establishments Minimum width: 900 mm (0.90 m) per door leaf. Double doors are common for wider spaces to comply with occupant load requirements. 4. Fire Doors Must meet fire-resistance ratings as per the Fire Code of the Philippines. Width requirements depend on the occupant load and egress requirements of the area. Special Considerations 1. Door Swing: Doors should swing outward for emergency exits or areas with high occupancy loads for faster egress. 2. Doors: Safety glass must be used, and visibility markings must be provided. Air Well Requirements Air Well Requirements Air wells are regulated under Rule VIII, Section 808 (Light and Ventilation) of the NBCP. 1. Residential Buildings Minimum Size: If an air well is used as a source of ventilation and lighting, its area must be at least 1.0 square meter per meter of height of the building. Minimum Width: For buildings of up to 2 storeys: 2.0 meters. For buildings over 2 storeys: 3.0 meters. 2. Commercial Buildings Minimum Size: The air well must provide sufficient ventilation and lighting for adjoining rooms. Area: At least 1/10 of the total floor area of the rooms it serves. Minimum Width: 3.0 meters for buildings higher than 2 storeys. 3. School Buildings Minimum Size: Similar to commercial buildings: At least 1/10 of the total floor area of the classrooms or spaces served. Minimum Width: 3.0 meters, especially for multi-storey structures. Air Well Requirements 4. Condominium or High-Rise Buildings Minimum Size: The air well should provide adequate ventilation for interior rooms and spaces without direct access to exterior windows. Area: At least 1/12 of the total floor area of the rooms served. Minimum Width: For buildings taller than 10 meters: Minimum of 3.0 meters. 5. Industrial Buildings Requirements: The air well should meet specific ventilation standards based on the operational needs and regulatory requirements for worker safety. Additional mechanical ventilation may be required if natural air wells are insufficient. Air Well Requirements General Guidelines for All Structures Location: Air wells should be placed to maximize airflow and natural light for the interior spaces. Shape: Air wells should preferably have a rectangular or square layout for efficient light and ventilation distribution. Accessibility: Air wells must be designed for maintenance access to ensure cleanliness and proper functioning. Combining with Shafts: In some cases, air wells may double as utility shafts for plumbing or electrical systems, provided they do not obstruct ventilation or light. Air Well Requirements Additional Notes 1. Mechanical Ventilation: If the natural air well does not meet ventilation needs, mechanical systems (e.g., exhaust fans) must supplement airflow as per NBCP requirements. 2. Local Ordinances: Cities or municipalities may have stricter requirements that supersede the NBCP. Part X: Environmental and Labor Laws Labor Laws in Construction Compliance with the Labor Code: Fair wages and benefits. Ensuring worker safety under DOLE standards. Part XI: Special Requirements for Specific Structures Requirements for Condominiums NBCP Guidelines for High-Rise Buildings: Structural safety for wind and seismic forces. Fire-rated materials and evacuation plans. Amenities and Common Areas: Elevators, parking, and recreational spaces. Accessibility Features: Elevators with tactile buttons and audio signals. Part XI: Special Requirements for Specific Structures Requirements for Commercial Complexes Energy Conservation: Solar panels and energy-efficient HVAC systems. Accessibility: Accessible entrances and washrooms. Utility Requirements: Sufficient water supply and waste management systems. Thank you!

Use Quizgecko on...
Browser
Browser