ANSI Standard Device Numbers & Common Acronyms Suffixes Description Suffixes Description _1 Positive-Sequence TDO Time-Delay Opening Contact _2 Negative-Sequence...

ANSI Standard Device Numbers & Common Acronyms Suffixes Description Suffixes Description _1 Positive-Sequence TDO Time-Delay Opening Contact _2 Negative-Sequence TDPU Time Delayed Relay Coil Pickup A Alarm, Auxiliary Power THD Total Harmonic Distortion AC Alternating Current TH Transformer (High-Voltage Side) AN Anode TL Transformer (Low-Voltage Side) B Bus, Battery, or Blower TM Telemeter BF Breaker Failure TT Transformer (Tertiary-Voltage Side) BK Brake U Under or Unit BL Block (Valve) X Auxiliary BP Bypass Z Impedance BT Bus Tie BU Backup C Capacitor, Condenser, Compensator, Carrier Current, Case, Acronyms Description or Compressor AFD Arc Flash Detector CA Cathode CLK Clock or Timing Source CH Check (Valve) CLP Cold Load Pickup D Discharge (Valve) DDR Dynamic Disturbance Recorder DC Direct Current DFR Digital Fault Recorder DCB Directional Comparison Blocking ENV Environmental Data DCUB Directional Comparison Unblocking HIZ High Impedance Fault Detector DD Disturbance Detector HMI Human Machine Interface DUTT Direct Underreaching Transfer Trip HST Historian E Exciter MET Substation Metering F Feeder, Field, Filament, Filter, or Fan PDC Phasor Data Concentrator G Ground or Generator PMU Phasor Measurement Unit GC Ground Check PQM Power Quality Monitor H Heater or Housing RIO Remote Input/Output Device L Line or Logic RTD Resistance Temperature Detector M Motor or Metering RTU Remote Terminal Unit / Data Concentrator MOC Mechanism Operated Contact SER Sequence of Events Recorder N Neutral or Network TCM Trip Circuit Monitor O Over VTFF Vt Fuse Fail P Phase or Pump PC Phase Comparison POTT Pott: Permissive Overreaching Transfer Trip PUTT Putt: Permissive Underreaching Transfer Trip R Reactor, Rectifier, or Room S Synchronizing, Secondary, Strainer, Sump, or Suction (Valve) SOTF Switch On To Fault T Transformer or Thyratron TD Time Delay TDC Time-Delay Closing Contact TDDO Time Delayed Relay Coil Drop-Out GEDigitalEnergy.com 1 ANSI Standard Device Numbers & Common Acronyms Device No. Description Device No. Description 1 Master Element 33 Position Switch 2 Time Delay Starting or Closing Relay 34 Master Sequence Device 3 Checking or Interlocking Realy 35 Brush-Operating or Slip-ring Short Circuiting Device 4 Master Contactor 36 Polarity or Polarizing Voltage Device 5 Stopping Device 37 Undercurrent or Underpower Relay 6 Starting Circuit Breaker 37P Underpower 7 Rate of Change Relay 38 Bearing Protective Device / Bearing Rtd 8 Control Power Disconnecting Device 39 Mechanical Condition Monitor 9 Reversing Device 40 Field Relay / Loss of Excitation 10 Unit Sequence Switch 41 Field Circuit Breaker 11 Multifunction Device 42 Running Circuit Breaker 12 Overspeed Device/Protection 43 Manual Transfer or Selector Device 13 Synchronous-Speed Device 44 Unit Sequence Starting Relay 14 Underspeed Device 45 Atmospheric Condition Monitor 15 Speed or Frequency Matching Device 46 Reverse-Phase or Phase Balance Current Relay or Stator 16 Communication Networking Device Current Unbalance 17 Shunting or Discharge Switch 47 Phase-Sequence or Phase Balance Voltage Relay 18 Accelerating or Decelerating Device 48 Incomplete Sequence Relay / Blocked Rotor 19 Motor Starter / Starting-to-Running Transition Contactor 49 Machine or Transformer Thermal Relay / Thermal Overload 20 Electrically-Operated Valve 49RTD RTD Biased Thermal Overload 21 Distance Relay 50 Instantaneous Overcurrent Relay 21G Ground Distance 50BF Breaker Failure 21P Phase Distance 50DD Current Disturbance Detector 22 Equalizer Circuit Breaker 50G Ground Instantaneous Overcurrent 23 Temperature Control Device 50N Neutral Instantaneous Overcurrent 24 Volts-per-Hertz Relay / Overfluxing 50P Phase Instantaneous Overcurrent 25 Synchronizing or Synchronism-Check Device 50_2 Negative Sequence Instantaneous Overcurrent 26 Apparatus Thermal Device 50/27 Accidental Energization 27 Undervoltage Relay 50/74 Ct Trouble 27P Phase Undervoltage 50/87 Instantaneous Differential 27TN Third Harmonic Neutral Undervoltage 50EF End Fault Protection 27X Auxiliary Undervoltage 50IG Isolated Ground Instantaneous Overcurrent 27 AUX Undervoltage Auxiliary Input 50LR Acceleration Time 27/27X Bus/Line Undervoltage 50NBF Neutral Instantaneous Breaker Failure 28 Flame Detector 50SG Sensitive Ground Instantaneous Overcurrent 29 Isolating Contactor 50SP Split Phase Instantaneous Current 30 Annunciator Relay 51 Ac Time Overcurrent Relay 31 Separate Excitation Device 51 Overload 32 Directional Power Relay 51G Ground Time Overcurrent 32L Low Forward Power 51N Neutral Time Overcurrent 32N Wattmetric Zero-Sequence Directional 51P Phase Time Overcurrent 32P Directional Power 51V Voltage Restrained Time Overcurrent 32R Reverse Power 51R Locked / Stalled Rotor 2 GEDigitalEnergy.com Device No. Description Device No. Description 51_2 Negative Sequence Time Overcurrent 76 Dc Overcurrent Relay 52 Ac Circuit Breaker 77 Telemetering Device 53 Exciter or Dc Generator Relay 78 Phase Angle Measuring or Out-of-Step Protective Relay 54 Turning Gear Engaging Device 78V Loss of Mains 55 Power Factor Relay 79 Ac Reclosing Relay / Auto Reclose 56 Field Application Relay 80 Liquid or Gas Flow Relay 57 Short-Circuiting or Grounding Device 81 Frequency Relay 58 Rectification Failure Relay 81O Over Frequency 59 Overvoltage Relay 81R Rate-of-Change Frequency 59B Bank Phase Overvoltage 81U Under Frequency 59P Phase Overvoltage 82 Dc Reclosing Relay 59N Neutral Overvoltage 83 Automatic Selective Control or Transfer Relay 59NU Neutral Voltage Unbalance 84 Operating Mechanism 59P Phase Overvoltage 85 Carrier or Pilot-Wire Receiver Relay 59X Auxiliary Overvoltage 86 Locking-Out Relay 59_2 Negative Sequence Overvoltage 87 Differential Protective Relay 60 Voltage or Current Balance Relay 87B Bus Differential 60N Neutral Current Unbalance 87G Generator Differential 60P Phase Current Unbalance 87GT Generator/Transformer Differential 61 Density Switch or Sensor 87LG Ground Line Current Differential 62 Time-Delay Stopping or Opening Relay 87S Stator Differential 63 Pressure Switch Detector 87S Percent Differential 64 Ground Protective Relay 87L Segregated Line Current Differential 64F Field Ground Protection 87M Motor Differential 64S Sub-harmonic Stator Ground Protection 87O Overall Differential 64TN 100% Stator Ground 87PC Phase Comparison 65 Governor 87RGF Restricted Ground Fault 66 Notching or Jogging Device/Maximum Starting Rate/Starts 87T Transformer Differential Per Hour/Time Between Starts 87V Voltage Differential 67 Ac Directional Overcurrent Relay 88 Auxiliary Motor or Motor Generator 67G Ground Directional Overcurrent 89 Line Switch 67N Neutral Directional Overcurrent 90 Regulating Device 67P Phase Directional Overcurrent 91 Voltage Directional Relay 67SG Sensitive Ground Directional Overcurrent 92 Voltage And Power Directional Relay 67_2 Negative Sequence Directional Overcurrent 93 Field-Changing Contactor 68 Blocking Relay / Power Swing Blocking 94 Tripping or Trip-Free Relay 69 Permissive Control Device 50/74 Ct Supervision 70 Rheostat 27/50 Accidental Generator Energization 71 Liquid Switch 27TN/59N 100% Stator Earth Fault 72 Dc Circuit Breaker 73 Load-Resistor Contactor 74 Alarm Relay 75 Position Changing Mechanism GEDigitalEnergy.com 3

Use Quizgecko on...
Browser
Browser