Which standard does IGU argue applies to its facility?

  • Section 328.2
  • NFPA 59A 6.3.4.1
  • NFPA 59A 10.114 (correct)
  • ASME B 31.3
  • What did the Notice allege about IGU's welding procedures?

  • They clearly stated which welding specifications to utilize
  • They were in accordance with Section 328.2 of ASME B 31.3
  • They were adequate because they relied on contractors and subcontractors
  • They failed to implement the requirements of NFPA 59A 6.3.4.1 (correct)
  • Why did IGU argue that its procedures were adequate?

  • Because they clearly stated which welding specifications to utilize
  • Because they used the most appropriate welding procedure specifications (correct)
  • Because they were in accordance with Section 328.2 of ASME B 31.3
  • Because they relied on contractors and subcontractors
  • According to NFPA 59A, which section of ASME B 31.3 is responsible for the qualification and performance of welders?

    <p>Section 328.2</p> Signup and view all the answers

    According to ASME B 31.3, who is responsible for conducting the tests required to qualify welding procedures and welders?

    <p>Each employer</p> Signup and view all the answers

    According to ASME B 31.3, under what conditions can welding procedures qualified by others be used?

    <p>With the approval of the Inspector</p> Signup and view all the answers

    What is the consequence of failing to comply with the Order?

    <p>Administrative assessment of civil penalties</p> Signup and view all the answers

    Study Notes

    Inadequate welding procedures alleged against IGU

    • Notice claimed IGU's welding procedures did not meet safety standards
    • NFPA 59A 6.3.4.1 requires welders to be qualified and perform in accordance with ASME B 31.3
    • IGU's procedures were criticized for not specifying which welding specifications to use
    • IGU argued that it relies on contractors and subcontractors with their own procedures
    • Section 193.2301 mandates compliance with Part 193 and NFPA-59A-2001 for LNG facilities
    • ASME B 31.3, Section 328.1 holds employers responsible for qualifying welding procedures and welders
    • IGU claimed it uses contractors' procedures but did not demonstrate alignment with ASME B 31.3
    • Respondent's procedures deemed inadequate for safe operation of the pipeline facility
    • Respondent ordered to amend procedures to include reviewing and documenting contractor and subcontractor welding procedures
    • Failure to comply may result in penalties or legal action
    • Inadequate cooldown and start-up procedures alleged against IGU
    • IGU's cooldown and start-up procedures were found to be corrected after review