PD 1096 QUIZ
45 Questions
40 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

Any physical change made in a building/structure to increase its value

  • ALTERATION
  • RENOVATION (correct)
  • ADDITION
  • MODIFICATION
  • ACCORDING TO THE NATIONAL BLDG. CODE, WHAT IS THE MAXIMUM COST OF A TRADITIONAL FAMILY DWELLING?

  • PHP10,000
  • PHP15,000 (correct)
  • PHP20,000
  • PHP25,000
  • WHICH OF THE FOLLOWING REQUIRES A BUILDING PERMIT?

  • GARDEN POOLS 500MM DEEP OR SHALLOWER
  • REPAIRS DOORS, FLOORS,, WINDOWS, OR FENCES
  • REPAIRS OF LOAD BEARING PARTITION WALLS (correct)
  • AN OPEN TERRACE 15SQM IN AREA
  • THIS PERSON IS TASKED WITH THE ENFORCEMENT OF THE NATIONAL BUILDING CODE IN HIS/HER JURISDICTION. HE/SHE ISSUES, DENIES, SUSPENDS, OR REVOKES BUILDING PERMITS.

    <p>THE BUILDING OFFICIAL</p> Signup and view all the answers

    WHICH OF THE FOLLOWING ARE EXEMPT FROM FEES?

    <p>BOTH A AND B</p> Signup and view all the answers

    ACCORDING TO BLDG. CODE, HOW MANY SETS OF PLANS AND SPECIFICAITONS MUST BE SUBMITTED WHEN APPLYING FOR A PERMIT?

    <p>5 SETS</p> Signup and view all the answers

    ACCORDING TO ARTICLE 1723 OF THE CIVIL CODE, WHO SHALL BE HELD LIABLE IF A BUILDING COLLAPSES DUE TO DEFECTS IN THE PLANS?

    <p>THE ARCHITECT OR ENGINEER WHO DREW UP THE PLANS</p> Signup and view all the answers

    BEFORE USING OR OCCUPYING A COMPLETED BLDG., THIS DOCUMENT MUST BE ISSUED FIRST.

    <p>CERT. OF OCCUPANCY</p> Signup and view all the answers

    THE BLDG. CODE REQUIRES THAT THE OWNER HIRE A FULL-TIME INSPECTOR FOR THE CONSTRUCTION. THE INSPECTOR MUST BE A:

    <p>EITHER A OR B</p> Signup and view all the answers

    THIS TERM REFERS TO ANY NEW CONSTRUCTION WHICH INCREASES THE HEIGHT OR THE AREA OF AN EXISTING BLDG,

    <p>ADDITION</p> Signup and view all the answers

    THIS TYPE OF CONSTRUCTION IS FOUR HOUR FIRE RESISTIVE THROUGHOUT.

    <p>TYPE V</p> Signup and view all the answers

    THE PROVISIONS OF THE NATIONAL BUILDING CODE APPLY TO ALL PUBLIC AND PRIVATE BUILDINGS EXCEPT FOR:

    <p>BP 220 PROJECTS</p> Signup and view all the answers

    IN WHICH FIRE ZONE CAN TYPE 3 CONSTRUCTION BE BUIILT?

    <p>A AND B ONLY</p> Signup and view all the answers

    WHICH REPAIR REQUIRES A PERMIT?

    <p>REPAIR OF A MINOR BEAM SUPPORTING A SECONDARY BALCONY</p> Signup and view all the answers

    WHICH OF THE FOLLOWING IS NOT A GROUND TO DECLARE A BLDG. AS DANGEROUS?

    <p>AESTHETIC DEFICIENCY</p> Signup and view all the answers

    WHAT IS THE MINIMUM DISTANCE REQUIRED BETWEEN ROOF EAVES AND REAR/SIDE PROPERTY LINES?

    <p>750MM</p> Signup and view all the answers

    FIREWALLS ARE NOT ALLOWED FOR R1 DEVELOPMENTS. HOWEVER, AN ABUTMENT OF UP TO ________ IN HEIGHT IS ALLOWED, PROVIDED THAT ABOVE 1.50M, THE ABUTMENT IS MADE OF PERFORATED CONCRETE BLOCKS.

    <p>3.20M</p> Signup and view all the answers

    FOR A SLOPING SLOT WITH A 4.00M DIFFERENCE BETWEEN THE HIGHEST AND THE LOWEST POINTS OF THE LOT, WHERE WILL THE ESTABLISHED GRADE LINE BE FOR BUILDING HEIGHT DETERMINATION?

    <p>THE AVERAGE BETWEEN THE TWO POINTS</p> Signup and view all the answers

    WHAT IS THE MINIMUM PARKING SLOT SIZE FOR AN ARTICULATED TRUCK?

    <p>3.60M X 18.00M</p> Signup and view all the answers

    IF YOU ADD THE ISA AND THE USA, WHAT WILL YOU GET?

    <p>TOSL</p> Signup and view all the answers

    IF YOU SUBTRACT THE ISA FROM THE CONSTRUCTION AREA, WHAT WILL YOU GET?

    <p>PSO</p> Signup and view all the answers

    WHAT IS THE MINIMUM AREA FOR HABITABLE ROOMS, ACCORDING TO THE NATIONAL BUILDING CODE?

    <p>6.00 SQM</p> Signup and view all the answers

    WHAT IS THE MINIMUM AIR SPACE PROVISION PER PERSON FOR HABITABLE ROOMS?

    <p>14 C.U.M.</p> Signup and view all the answers

    WHAT IS THE MINIMUM CEILING HEIGHT REQUIRED FOR THE SEVENTH FLOOR OF AN ARTIFICIALLY VENTILATED BUILDING?

    <p>2.10M</p> Signup and view all the answers

    FOR FOREST AREAS, THE NBC REQUIRES AT LEAST ________ OF EASEMENT FOR EACH SIDE OF THE WATERWAY

    <p>40.00 M</p> Signup and view all the answers

    ROWHOUSES 1-3 STOREYS HIGH FALL UNDER WHICH ZONING CLASSIFICATION?

    <p>R3</p> Signup and view all the answers

    WHAT ARE THE ALLOWABLE FIREWALL CONFIGURATIONS FOR AN R2 PROJECT?

    <p>ALLOWED ON ONE SIDE OF THE PROPERTY</p> Signup and view all the answers

    FOR R4 PROJECTS, FIREWALLS MAY BE ALLOWED ON BOTH SIDES OF THE PROPERTY. WHAT IS THE MAXIMUM HEIGHT FOR THESE FIREWALLS?

    <p>3 FLOORS HIGH ONLY</p> Signup and view all the answers

    ALL OF THESE AFFECT THE MAXIMUM TOTAL GROSS FLOOR AREA GIVEN BY TABLE 7.1 EXCEPT FOR:

    <p>WIDTH OF THE ROAD</p> Signup and view all the answers

    WEHN THE ONLY ROAD FRONTING A PROPERTY IS 5 METERS WIDE AND THE PROPERTY IS ZONED AS R1, THE MAXIMUM HEIGHT ALLOWED FOR THE PROJECT IS:

    <p>2.5 FLOORS ONLY</p> Signup and view all the answers

    WHAT IS THE MAXIMUM PROJECTION ALLOWED FOR A FOOTING, BURIED 600MM BELOW GRADE, TOWARDS A PUBLIC SIDEWALK?

    <p>500MM</p> Signup and view all the answers

    FENCES SHOULD BE INSTALLED AROUND THE CONSTRUCTION OR DEMOLITION SITE. WHAT IS THE MINIMUM HEIGHT REQUIRED FOR THE FENCE?

    <p>2.40M</p> Signup and view all the answers

    IF THE DISTANCE BETWEEN THE OUTERMOST FACE OF THE BUILDING AND THE INNER EDGE OF THE SIDEWALK IS EQUAL TO THE BUILDING HEIGHT, WHAT IS REQUIRED?

    <p>A FENCE ONLY</p> Signup and view all the answers

    WHAT IS THE MINIMUM SIZE OF A CLASSROOM FOR 30 STUDENTS AND 1 TEACHER, ACCORDING TO THE OCCUPANT LOAD FACTOR N RULE 12 OF THE BUILDING CODE?

    <p>55.80 SQM</p> Signup and view all the answers

    WHAT IS THE OCCUPANT LOAD FACTOR FOR HOTELS, ACCORDING TO RULE 12

    <p>18.60 SQM/PERSON</p> Signup and view all the answers

    A FLOOR WITH AN OCCUPANT LOAD OF 700 SHALL HAVE AT LEAST HOW MANY EXITS?

    <p>3</p> Signup and view all the answers

    WHAT IS THE MAXIMUM TRAVEL DISTANCE TO AN EXIT IF THE BUILDING HAS AN AUTOMATIC FIRE EXTINGUISHING SYSTEM?

    <p>60 METERS</p> Signup and view all the answers

    WHAT IS THE MINIMUM HEIGHT REQUIRED FOR DOORS IN THE BUILDING CODE?

    <p>2.00 METERS</p> Signup and view all the answers

    WHAT IS THE MINIMUM STAIR WIDTH REQUIRED IF THE OCCUPANT LOAD IS 15?

    <p>900MM</p> Signup and view all the answers

    WHAT IS THE CORRECT MOUNTING HEIGHT OF HANDRAILS, ACCORDING TO THE BUILDING CODE?

    <p>800-900MM</p> Signup and view all the answers

    WHAT IS THE MINIMUM DEPTH FOR ELEVATOR PITS?

    <p>600MM</p> Signup and view all the answers

    WHAT IS THE MAXIMUM NUMBER OF SEATS BETWEEN TWO AISLES?

    <p>14 SEATS</p> Signup and view all the answers

    MINIMUM THICKNESS OF A GLASS PANEL MEASURING 2.50M X 2.50M

    <p>12MM</p> Signup and view all the answers

    MAXIMUM WIDTH OF A DOOR LEAF

    <p>1200MM</p> Signup and view all the answers

    WHAT IS THE MAXIMUM NUMBER OF SEATS BETWEEN A WALL AND AN AISLE?

    <p>7 SEATS</p> Signup and view all the answers

    Study Notes

    Building and Construction

    • Any physical change made to a building or structure to increase its value is considered an alteration.

    National Building Code

    • The maximum cost of a traditional family dwelling is according to the National Building Code.
    • The building official is tasked with enforcing the National Building Code in their jurisdiction and has the authority to issue, deny, suspend, or revoke building permits.

    Building Permits and Fees

    • A building permit is required for any construction, alteration, or repair work.
    • The following are exempt from fees: public buildings, charitable institutions, and religious buildings.
    • Four sets of plans and specifications must be submitted when applying for a permit.

    Liability and Inspections

    • According to Article 1723 of the Civil Code, the person responsible for the building's design and construction shall be held liable if a building collapses due to defects in the plans.
    • A full-time inspector must be hired by the owner for the construction, and the inspector must be a registered architect or engineer.

    Construction Types

    • "Addition" refers to any new construction which increases the height or the area of an existing building.
    • Type 3 construction is four-hour fire-resistant throughout and can be built in fire zones.

    Exemptions and Exceptions

    • The National Building Code provisions apply to all public and private buildings except for detached one- or two-family dwellings.

    Fire Zones and Construction

    • Type 3 construction can be built in fire zones.
    • Firewalls are not allowed for R1 developments, but an abutment of up to 1.50m in height is allowed, provided that above 1.50m, the abutment is made of perforated concrete blocks.

    Building Height and Grading

    • For a sloping slot with a 4.00m difference between the highest and the lowest points of the lot, the established grade line will be at the midpoint of the lot.
    • The minimum distance required between roof eaves and rear/side property lines is 1.50m.

    Parking and Accessibility

    • The minimum parking slot size for an articulated truck is 12.00m x 3.00m.
    • The minimum area for habitable rooms is 9.00m².
    • The minimum air space provision per person for habitable rooms is 2.00m².
    • The minimum ceiling height required for the seventh floor of an artificially ventilated building is 2.40m.

    Zoning and Land Use

    • Rowhouses 1-3 storeys high fall under the R2 zoning classification.
    • For R4 projects, firewalls may be allowed on both sides of the property, with a maximum height of 2.10m.
    • For forest areas, the NBC requires at least 3.00m of easement for each side of the waterway.

    Building Features and Dimensions

    • The minimum height required for doors is 2.00m.
    • The minimum stair width required if the occupant load is 15 is 1.10m.
    • The correct mounting height of handrails is between 0.80m and 1.00m.
    • The minimum depth for elevator pits is 1.20m.
    • The maximum number of seats between two aisles is 7.
    • The minimum thickness of a glass panel measuring 2.50m x 2.50m is 12.00mm.
    • The maximum width of a door leaf is 1.20m.
    • The maximum number of seats between a wall and an aisle is 3.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    More Like This

    Use Quizgecko on...
    Browser
    Browser