What precaution should be taken before touching the apparatus inside the BSC?

  • Do not pipette in/out too strong
  • Clean the floor if needed
  • Always wipe your hand with alcohol first (correct)
  • Wipe the wall of the BSC with tissue
  • How should you handle going out of BSL3 effectively?

  • Doff booties into the bin two at a time
  • Remove shoe covers one at a time while stepping into a 'clean zone' (correct)
  • Clean the floor if needed
  • Remove outer gloves and face mask first
  • What should be done after finishing work inside the BSC?

  • Set the incubator if needed
  • Take out the waste plastic bag and lay on surface and decon
  • Remove shoe covers one at a time
  • Clean the outer part of the bin inside out (correct)
  • What is one of the precautions mentioned when entering or exiting the BSC?

    <p>Wipe hand with alcohol after touching apparatus</p> Signup and view all the answers

    How should you handle waste disposal according to the text?

    <p>Label the waste date/name and store it for more than 24 hours</p> Signup and view all the answers

    What is recommended to do to minimize movement inside the BSC?

    <p>Pipette in and out slowly</p> Signup and view all the answers

    What should be done after entering the BSL3 laboratory?

    <p>Check the pressure gauges and switch on the BSC</p> Signup and view all the answers

    What is the purpose of wiping the prep desk with 70% alcohol?

    <p>To deactivate the virus or waste in waste beaker/bottle</p> Signup and view all the answers

    What should be done before bringing things from the passer box onto the clean area?

    <p>Wipe the prep desk with 70% alcohol</p> Signup and view all the answers

    What is the last step before starting work in the BSL3 laboratory?

    <p>Wipe one part of panel creating a clean area</p> Signup and view all the answers

    What should be done after wearing the suits before moving to the middle room?

    <p>Check if everything is okay</p> Signup and view all the answers

    What should be done after entering the middle room/airlock room?

    <p>Check if the door is closed properly and check the light</p> Signup and view all the answers

    What should you do upon arriving at the BSL3 area?

    <p>Check the pressure gauge for safety level</p> Signup and view all the answers

    What should you do if the pressure gauge in the back of the lab is not normal?

    <p>Alert others</p> Signup and view all the answers

    What should you do before entering the outer airlock of the BSL3 area?

    <p>Write name on whiteboard at the entrance door</p> Signup and view all the answers

    What is the correct order for donning safety gear before entering the BSL3 laboratory?

    <p>Invert the glove, tape it to Tyvek, wear N95 respirator</p> Signup and view all the answers

    What should you do if the pressure gauge in the outer airlock deviates from normal reading?

    <p>Do NOT ENTER BSL3 laboratory</p> Signup and view all the answers

    What should be done with all belongings/personal items upon entering the BSL3 area?

    <p>Place them in a basket on the table</p> Signup and view all the answers

    What should be done first when doffing the Tyvek suit?

    <p>Remove the booties and roll down the suit from the neck</p> Signup and view all the answers

    What item should be disinfected with 70% ethanol?

    <p>The goggles</p> Signup and view all the answers

    What is the correct way to remove the N95 respirator?

    <p>Remove head cap together with mask and inner gloves</p> Signup and view all the answers

    Where should personal items be taken after doffing gloves?

    <p>Anteroom</p> Signup and view all the answers

    What should be done after removing the name from the whiteboard at the entrance door?

    <p>Report any incidents in incident logbook if any</p> Signup and view all the answers

    What should be done before returning access cards/keys?

    <p>Log in if use</p> Signup and view all the answers

    Study Notes

    Laboratory Procedure

    • Wipe the apparatus and put it on a clean area in the Biosafety Cabinet (BSC)
    • Bring out clean apparatus to the tabletop
    • Wipe the working pad with alcohol and dispose of it in a waste plastic bin
    • Take out the waste plastic bag, lay it on a surface, and decontaminate it
    • Wipe the outer part of the bin from the bottom to the top and then inside
    • Decontaminate the surface and walls of the BSC inside and out
    • Let the BSC purge for a few minutes (~10 minutes)
    • Bring down the mirror and switch off the BSC

    Decontamination Precautions

    • Always wipe your hands with alcohol before touching apparatus
    • Be aware of clean and dirty areas
    • Minimize movement inside the BSC
    • Avoid pipetting too strongly and do it slowly
    • Avoid touching your face or mask
    • Wipe your hands with alcohol when entering and exiting the BSC

    Exiting BSL3 Laboratory

    • Label waste with date and name, and store it for more than 24 hours
    • Set the incubator if needed
    • Clean the floor if needed (monthly)
    • Place necessary items in the passer box
    • Doff booties one at a time while stepping into a "clean zone"
    • Remove outer gloves
    • Enter the airlock (next room)
    • Remove shoe covers one at a time while stepping into the "clean zone"
    • Check the mask fitness with a sucking air test
    • Enter the next room (middle room/airlock room)
    • Wear the second glove normally
    • Take goggles and wipe them with 70% ethanol
    • Last check for everything using the mirror
    • Enter the BSL3 laboratory

    Inside BSL3 Laboratory

    • Check the pressure gauges
    • Switch on the BSC, lift the glass door to the sash level, and let the blower ON for a few minutes
    • Prepare other required equipment like the centrifuge machine and computer
    • Refill the distilled water bottle
    • Wipe the prep desk with 70% alcohol
    • Bring things from the passer box to the clean area
    • Prepare necessary items like Absorbent pad, 70% alcohol spray, and Clorox for deactivating the virus
    • Wipe the BSC with a disinfectant
    • Divide the working area (clean/dirty/working space)
    • Spray hands with alcohol and start work

    Steps Going into BSL3

    • Alert others in WhatsApp group about checking in and working hours
    • Ensure specimens/samples are contained in sealable plastic bags and covered in a container
    • Check the surrounding area and pressure gauge for safety
    • Enter the autoclave room and switch on the autoclave if required
    • Check the whiteboard for reminders and log in to the entry and exit logbook
    • Check the sign on the door before entering the outer airlock

    Suit Up Procedure

    • Change into laboratory shoes/sandals
    • Place the basket containing the transfer box and materials at the side
    • Transfer the carried items to be used in BSL3 into the BSL3 passerbox
    • Cut the tape and put it on the wall
    • Gather items for suit-up on the desk
    • Don Tyvek, nitrile gloves, shoe covers, booties, mask, head cover, and N95 respirator
    • Ensure proper fit of the respirator

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Test your knowledge on the safety protocol for entering a BSL3 area according to Suhaimi Draman's steps. Learn about checking in, handling specimens, and ensuring safety measures are in place before starting work.