Server Room Fire Prevention Quiz

RightSmokyQuartz1782 avatar
RightSmokyQuartz1782
·
·
Download

Start Quiz

Study Flashcards

24 Questions

What is a common cause of server room fires related to electrical components?

Overloading plug sockets

What can lead to overheating electronics in a server room?

Failure of AC

What can cause subfloor wiring problems in a server room?

Weak subfloors

Why are server room walls more vulnerable to fires igniting nearby?

Presence of holes and conduits for cables

What is recommended to prevent dirt and grease buildup in a server room?

Keeping the server room clean and clutter-free

What action is recommended to prevent server room fires?

Carrying out a Fire Risk Assessment

What is the acceptable operating temperature range recommended by ASHRAE for a server room?

18° to 27°C

What organization is responsible for setting standards related to heating, refrigerating, and air-conditioning engineers?

ASHRAE

What is the purpose of proper ventilation in a server room?

To prevent equipment overheating

What can help in preventing equipment overheating in a server room?

Keeping the room cool

What is a recommended action to keep the server room clutter-free?

Avoiding the use of boxes

What should be consulted to ensure proper ventilation in a server room?

The HVAC team

What is the Delta temperature in the context of cooling techniques?

The difference in temperature between the air being used for cooling and the temperature of the equipment

What is the recommended operating temperature range for maximum uptime and hardware life according to ASHRAE 2005?

18° to 27°C

What is the recommended humidity level for data centers according to ASHRAE's 2016 guidelines?

40 to 50%

What is the purpose of placing various temperature and humidity sensors in key locations in the server room?

To monitor environmental conditions and ensure proper cooling

What is the function of a thermostat in a server room cooling system?

To provide a simple user interface with the internal workings of the climate control system

What is the purpose of the hot/cold aisle layout in a data center?

To ensure consistent airflow direction throughout the rows of racks

What is the function of a portable AC unit in a server room?

To act as a temporary solution for cooling

What is the purpose of evaporative cooling in a data center?

To introduce liquid water directly into the air without adding thermal energy

What is the recommended method for monitoring the cooling systems and equipment distribution in a server room?

Monitor temperature, airflow, and humidity at the rack-level

What is the purpose of a humidifier in a data center?

To prevent electrostatic discharge damaging servers and offer evaporative cooling

What is the function of a two-wire thermostat in an HVAC system?

To serve as a simple user interface with the internal workings of the climate control system

What is the purpose of monitoring temperature, humidity, and airflow in the server room?

To ensure proper cooling and equipment safety

Test your knowledge of server room fire prevention and safety with this quiz. Learn about common causes of server room fires, such as electrical failures, overheating electronics, and subfloor wiring problems. Find out how to identify and address potential fire hazards to protect your server room and equipment.

Make Your Own Quizzes and Flashcards

Convert your notes into interactive study material.

Get started for free

More Quizzes Like This

Are You a Master Server?
11 questions
Server-Side Computing Model Quiz (Lec2)
30 questions
Server Room Fire Risks and Protection Quiz
36 questions
Use Quizgecko on...
Browser
Browser