38 Questions
What is a common cause of server room fires according to the text?
Overloading plug sockets
Why is protecting the server room from fire important?
It safeguards the entire business
What percentage of total input power to the data center is used for cooling, according to the text?
38%
What can cause components in the server room to overheat to the point of ignition?
Failure of cooling systems
What type of wire is typically used in most thermostats?
18-Gauge, 5 Conductor, Solid Copper Thermostat Wire
What type of transducer is a thermistor?
Two-terminal transducer
What does a thermistor sense?
Change in temperature
What voltage does the control board output for a low voltage signal?
5VDC
What voltage does the power relay board turn on?
240VAC
What can sudden temperature changes indicate in a server environment?
Problems or failure of the local air conditioning system
What can rising moisture levels indicate in an IT environment?
Incorrect air conditioning system settings
What is the symbol for a thermistor?
Refer to Figure 13
What is the approximate resistance of a thermistor at 10°C?
800 ohms
What is the approximate resistance of a thermistor at 30°C?
600 ohms
What is the approximate resistance of a thermistor at 50°C?
400 ohms
What can extreme heat and high humidity cause to mission-critical equipment?
Major damage
What is the recommended temperature range for server rooms according to ASHRAE?
18° to 27°C
Where should digital temperature sensors be placed in a server room?
Every 7-8m, or closer for heat-generating appliances like blade servers
What is the ideal humidity level for server rooms?
40% to 50%
What can high humidity levels in server rooms lead to?
Water condensation on systems, potentially causing power shortages
How can low humidity in server rooms affect computer equipment?
Leads to electrostatic discharge, damaging sensitive components
What is the purpose of humidifiers in server rooms?
To prevent electrostatic discharge and offer high-capacity, low-cost evaporative cooling
How does evaporative cooling reduce mechanical cooling requirements in data centers?
By introducing liquid water into the air without adding thermal energy
What layout is crucial for consistent airflow direction throughout server racks?
Hot aisle/cold aisle layout
How do containment systems improve cooling and energy efficiency in server rooms?
By preventing hot exhaust air from mixing with cold air
What is the role of the thermostat in a server room?
To provide a simple user interface with the internal workings of the climate control system
What is the recommended data center temperature range for optimal uptime and hardware life?
20° to 24°C
What is the purpose of row cooling systems in server rooms?
To cool the racks' interiors using chilled water
What is the goal of HVAC systems in server rooms?
To decrease the temperature
What is the recommended method to prevent fires in server rooms?
Regularly carry out fire risk assessments
What can dust and grease buildup in server rooms cause?
Increased risk of fires
What is the purpose of rack cooling systems in server rooms?
To circulate enough air to prevent hot spots
What is the role of multiple row chillers in server rooms?
To provide redundancy in case one unit fails
What is the impact of keeping the server room cool?
Decreased equipment overheating and fire risk
Why is proper ventilation crucial for fire prevention in server rooms?
To remove noxious gases and prevent fires
What is the purpose of the Delta temperature method in server rooms?
To keep computer equipment running at safe temperatures
What is the role of air conditioning options in server rooms?
To decrease the temperature using the Delta temperature method
What is the recommended approach to maintaining the server room for fire prevention?
Maintain a clutter-free environment and perform fire inspections
Study Notes
Server Room Cooling Systems and Fire Prevention
- Server rooms are vulnerable to fires that can quickly engulf the room and become a source of deadly noxious gases.
- Dust and grease buildup in server rooms can cause equipment to overheat and become a ready source of fuel for fires.
- To prevent fires, it is recommended to carry out a fire risk assessment, keep the server room clean and clutter-free, and perform fire inspections.
- Keeping the server room cool helps prevent equipment overheating and lowers the fire risk.
- HVAC systems in server rooms consist of the furnace, heat exchanger, fans, and ductwork, with the goal of decreasing the temperature.
- Air conditioning options for server rooms include room cooling, rack cooling, and row cooling systems.
- Room cooling relies on the air conditioning system to circulate enough air to prevent hot spots, while rack cooling systems come in two forms: air cooling using the server room cooled air and self-contained rack cooling units.
- Row cooling extends rack cooling to an entire row of racks and may use chilled water to actively cool the racks’ interiors.
- Multiple row chillers provide redundancy in case one unit fails, and the Delta temperature method is used to keep computer equipment running at safe temperatures.
- The recommended data center temperature range is 20° to 24°C for optimal uptime and hardware life, as advised by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
- Proper ventilation, suitable cooling equipment, and a clutter-free environment are crucial for fire prevention in server rooms.
- Maintaining the server room within the recommended temperature range is essential for maximizing uptime and providing a buffer in the event of an air conditioning failure.
Test your knowledge of server room cooling systems and fire prevention with this quiz. Explore the importance of proper ventilation, recommended temperature ranges, and various cooling options to safeguard against equipment overheating and fire hazards.