Server Room Cooling and Fire Prevention Quiz
38 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is a common cause of server room fires according to the text?

  • Inadequate fire extinguisher placement
  • Lack of ventilation in the server room
  • Excessive use of cooling systems
  • Overloading plug sockets (correct)
  • Why is protecting the server room from fire important?

  • It safeguards the entire business (correct)
  • It increases data storage capacity
  • It prevents electrical failures
  • It reduces cooling costs
  • What percentage of total input power to the data center is used for cooling, according to the text?

  • 25%
  • 38% (correct)
  • 50%
  • 60%
  • What can cause components in the server room to overheat to the point of ignition?

    <p>Failure of cooling systems</p> Signup and view all the answers

    What type of wire is typically used in most thermostats?

    <p>18-Gauge, 5 Conductor, Solid Copper Thermostat Wire</p> Signup and view all the answers

    What type of transducer is a thermistor?

    <p>Two-terminal transducer</p> Signup and view all the answers

    What does a thermistor sense?

    <p>Change in temperature</p> Signup and view all the answers

    What voltage does the control board output for a low voltage signal?

    <p>5VDC</p> Signup and view all the answers

    What voltage does the power relay board turn on?

    <p>240VAC</p> Signup and view all the answers

    What can sudden temperature changes indicate in a server environment?

    <p>Problems or failure of the local air conditioning system</p> Signup and view all the answers

    What can rising moisture levels indicate in an IT environment?

    <p>Incorrect air conditioning system settings</p> Signup and view all the answers

    What is the symbol for a thermistor?

    <p>Refer to Figure 13</p> Signup and view all the answers

    What is the approximate resistance of a thermistor at 10°C?

    <p>800 ohms</p> Signup and view all the answers

    What is the approximate resistance of a thermistor at 30°C?

    <p>600 ohms</p> Signup and view all the answers

    What is the approximate resistance of a thermistor at 50°C?

    <p>400 ohms</p> Signup and view all the answers

    What can extreme heat and high humidity cause to mission-critical equipment?

    <p>Major damage</p> Signup and view all the answers

    What is the recommended temperature range for server rooms according to ASHRAE?

    <p>18° to 27°C</p> Signup and view all the answers

    Where should digital temperature sensors be placed in a server room?

    <p>Every 7-8m, or closer for heat-generating appliances like blade servers</p> Signup and view all the answers

    What is the ideal humidity level for server rooms?

    <p>40% to 50%</p> Signup and view all the answers

    What can high humidity levels in server rooms lead to?

    <p>Water condensation on systems, potentially causing power shortages</p> Signup and view all the answers

    How can low humidity in server rooms affect computer equipment?

    <p>Leads to electrostatic discharge, damaging sensitive components</p> Signup and view all the answers

    What is the purpose of humidifiers in server rooms?

    <p>To prevent electrostatic discharge and offer high-capacity, low-cost evaporative cooling</p> Signup and view all the answers

    How does evaporative cooling reduce mechanical cooling requirements in data centers?

    <p>By introducing liquid water into the air without adding thermal energy</p> Signup and view all the answers

    What layout is crucial for consistent airflow direction throughout server racks?

    <p>Hot aisle/cold aisle layout</p> Signup and view all the answers

    How do containment systems improve cooling and energy efficiency in server rooms?

    <p>By preventing hot exhaust air from mixing with cold air</p> Signup and view all the answers

    What is the role of the thermostat in a server room?

    <p>To provide a simple user interface with the internal workings of the climate control system</p> Signup and view all the answers

    What is the recommended data center temperature range for optimal uptime and hardware life?

    <p>20° to 24°C</p> Signup and view all the answers

    What is the purpose of row cooling systems in server rooms?

    <p>To cool the racks' interiors using chilled water</p> Signup and view all the answers

    What is the goal of HVAC systems in server rooms?

    <p>To decrease the temperature</p> Signup and view all the answers

    What is the recommended method to prevent fires in server rooms?

    <p>Regularly carry out fire risk assessments</p> Signup and view all the answers

    What can dust and grease buildup in server rooms cause?

    <p>Increased risk of fires</p> Signup and view all the answers

    What is the purpose of rack cooling systems in server rooms?

    <p>To circulate enough air to prevent hot spots</p> Signup and view all the answers

    What is the role of multiple row chillers in server rooms?

    <p>To provide redundancy in case one unit fails</p> Signup and view all the answers

    What is the impact of keeping the server room cool?

    <p>Decreased equipment overheating and fire risk</p> Signup and view all the answers

    Why is proper ventilation crucial for fire prevention in server rooms?

    <p>To remove noxious gases and prevent fires</p> Signup and view all the answers

    What is the purpose of the Delta temperature method in server rooms?

    <p>To keep computer equipment running at safe temperatures</p> Signup and view all the answers

    What is the role of air conditioning options in server rooms?

    <p>To decrease the temperature using the Delta temperature method</p> Signup and view all the answers

    What is the recommended approach to maintaining the server room for fire prevention?

    <p>Maintain a clutter-free environment and perform fire inspections</p> Signup and view all the answers

    Study Notes

    Server Room Cooling Systems and Fire Prevention

    • Server rooms are vulnerable to fires that can quickly engulf the room and become a source of deadly noxious gases.
    • Dust and grease buildup in server rooms can cause equipment to overheat and become a ready source of fuel for fires.
    • To prevent fires, it is recommended to carry out a fire risk assessment, keep the server room clean and clutter-free, and perform fire inspections.
    • Keeping the server room cool helps prevent equipment overheating and lowers the fire risk.
    • HVAC systems in server rooms consist of the furnace, heat exchanger, fans, and ductwork, with the goal of decreasing the temperature.
    • Air conditioning options for server rooms include room cooling, rack cooling, and row cooling systems.
    • Room cooling relies on the air conditioning system to circulate enough air to prevent hot spots, while rack cooling systems come in two forms: air cooling using the server room cooled air and self-contained rack cooling units.
    • Row cooling extends rack cooling to an entire row of racks and may use chilled water to actively cool the racks’ interiors.
    • Multiple row chillers provide redundancy in case one unit fails, and the Delta temperature method is used to keep computer equipment running at safe temperatures.
    • The recommended data center temperature range is 20° to 24°C for optimal uptime and hardware life, as advised by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
    • Proper ventilation, suitable cooling equipment, and a clutter-free environment are crucial for fire prevention in server rooms.
    • Maintaining the server room within the recommended temperature range is essential for maximizing uptime and providing a buffer in the event of an air conditioning failure.