SCBA Cylinder Valve Assembly and Warning Device
8 Questions
2 Views

SCBA Cylinder Valve Assembly and Warning Device

Created by
@StatelyCliché

Questions and Answers

What activates the primary low pressure warning device during use?

  • 40 percent of the SCBA's rated service pressure
  • 50 percent of the SCBA's rated service pressure
  • 35 percent of the SCBA's rated service pressure (correct)
  • 30 percent of the SCBA's rated service pressure
  • What is a feature of the cylinder valve assembly's pressure gauge?

  • It is retro-reflective for visibility.
  • It includes a photoluminescent face. (correct)
  • It is connected to a wireless alarm.
  • It has a digital display.
  • What is the purpose of the pressure-relief device in the cylinder valve assembly?

  • To automatically refill the cylinder
  • To store additional air
  • To vent pressure safely if over-pressurized (correct)
  • To enhance cylinder installation
  • What feature is NOT provided by the shoulder pads in the G1 Carrier and Harness Assembly?

    <p>Adjustable length for different heights</p> Signup and view all the answers

    What is the drag rating of the hop handle on the ergonomic backplate?

    <p>1000 lbs</p> Signup and view all the answers

    What does the cylinder band do in the G1 Carrier and Harness Assembly?

    <p>Securely retains the cylinder</p> Signup and view all the answers

    What is the function of the adjustable pull straps in the harness assembly?

    <p>To provide a secure fit</p> Signup and view all the answers

    At what PSI does the bell alarm for low pressure actuate?

    <p>1575 PSI</p> Signup and view all the answers

    Study Notes

    Cylinder Valve Assembly

    • Features a large pressure gauge with photoluminescent face for visibility.
    • Non-locking handwheel for easy operation of the cylinder valve assembly.
    • Includes a pressure-relief device to safely vent over-pressurized cylinders.

    Primary Low Pressure Warning Device (Bell)

    • Engages automatically at 35% of SCBA's rated service pressure, approximately 1575 PSI.
    • Activates when there are about 16 minutes of service time remaining.

    G1 Carrier and Harness Assembly

    • Comprises various components designed for safety and comfort:
      • Backplate: Houses power module, battery module, and pressure reducer; includes large handles for handling and storage with drag ratings of 1000 lbs (hop handle) and 500 lbs (side handles).
      • Cylinder Band: Metal construction with a latch, ensuring secure retention and facilitating cylinder installation/removal.
      • Shoulder Pads: Designed for weight distribution, featuring a friction pad to minimize strap slippage, retroreflective materials for visibility, and steel buckles for security. Snap buttons allow easy replacement or repair of components.
      • Lumbar Pad: Provides additional support and comfort to the lower back during use.
      • Adjustable Pull Straps: Facilitate customization of fit for different users.
      • Waist Belt: Enhances stability and comfort.
      • Regulator Keeper: Secures the regulator in place for easy access and use.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz covers the components and features of SCBA cylinder valve assembly and primary low pressure warning device, including pressure gauges and handwheels.

    More Quizzes Like This

    SOP 74 part deux
    55 questions

    SOP 74 part deux

    ResourcefulPointillism avatar
    ResourcefulPointillism
    Use Quizgecko on...
    Browser
    Browser