Rescue Team Procedures Quiz
40 Questions
6 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the required radio designation for the three-member Rescue team?

  • Rescue (correct)
  • Rescue Alpha
  • Rescue One
  • Rescue Team
  • Which of the following is NOT a requirement for the backup team before entering a hot zone?

  • They must have full PPE.
  • They must be operating hose lines. (correct)
  • They must be equipped with SCBA.
  • They must have a radio.
  • What should be done if entry into a hot zone is necessary but the backup team is not assembled?

  • Notify incoming crews of your intentions and location. (correct)
  • Wait for additional personnel to arrive.
  • Conduct routine primary searches immediately.
  • Proceed without notifying anyone.
  • Under what circumstance can interior firefighting commence without an assembled backup team?

    <p>When immediate action is needed to save a life.</p> Signup and view all the answers

    Which of the following best describes the backup team's role?

    <p>To stand by fully equipped and ready to assist.</p> Signup and view all the answers

    When reporting a member's status, what format should be used?

    <p>Company number along with that member's last name.</p> Signup and view all the answers

    Which of these statements is true regarding essential duties of team members?

    <p>Backup team members cannot perform essential duties.</p> Signup and view all the answers

    What is meant by a 'hot zone' in firefighting operations?

    <p>An interior firefighting area or IDLH area.</p> Signup and view all the answers

    What is the primary concern when parking near a hazardous materials incident?

    <p>Park uphill and upwind from the spill</p> Signup and view all the answers

    Which action should be taken first when establishing command at a fire scene?

    <p>Communicate situation found and actions being taken to dispatch</p> Signup and view all the answers

    What is the minimum hose length recommended for surrounding a vehicle during a fire attack?

    <p>100 feet of 1¾” hose</p> Signup and view all the answers

    What type of stream should be used initially for a vehicle fire involving gasoline?

    <p>A sweeping fog stream at a 30-degree angle</p> Signup and view all the answers

    During the termination phase of an incident, what is a key action that must be performed?

    <p>Collect and record all pertinent information</p> Signup and view all the answers

    What should be used to establish a safety zone around the incident?

    <p>Traffic cones, rigs, and personnel to reroute traffic</p> Signup and view all the answers

    What is the primary responsibility of the second ladder company upon arrival at a scene?

    <p>To report to the Incident Commander with proper tool selection</p> Signup and view all the answers

    Which protective gear is essential to use in smoke-filled areas?

    <p>Full PPE and SCBA</p> Signup and view all the answers

    What is one of the recommended alternative extinguishing agents for fire attack and overhaul?

    <p>Dry chemical agents</p> Signup and view all the answers

    In the context of crew assignments, when is roof ventilation considered the number one priority?

    <p>When it is deemed necessary by the crew</p> Signup and view all the answers

    Which tool selection is essential for a complicated forcible entry task?

    <p>A rabbit tool and a Halligan</p> Signup and view all the answers

    What should a crew do if they encounter hidden fire during their operations?

    <p>Perform general overhaul and salvage duties</p> Signup and view all the answers

    What is a key protocol for accountability within ladder companies?

    <p>Report any change in floor level to the incident commander</p> Signup and view all the answers

    When should thermal imaging cameras be deployed?

    <p>At all structure fires to detect heat and evaluate conditions</p> Signup and view all the answers

    What is the suggested approach regarding aerial apparatus placement?

    <p>Apparatus placement should prioritize non-committal areas whenever possible</p> Signup and view all the answers

    How should incoming truck companies be organized during a multiple alarm situation?

    <p>They should stage and wait for orders</p> Signup and view all the answers

    What makes gasoline particularly difficult to extinguish?

    <p>It does not react with water.</p> Signup and view all the answers

    Which of the following is NOT a type of Master Stream appliance?

    <p>Hand-held Hose Streams</p> Signup and view all the answers

    What is the flow rate range of Master Streams as defined in the guidelines?

    <p>400 – 1000 + GPM</p> Signup and view all the answers

    What is the primary reason for not introducing Master Streams into a structure during interior firefighting operations?

    <p>They can change the fire dynamics unpredictably.</p> Signup and view all the answers

    Which of the following is considered a hazardous cargo that firefighters must be cautious of?

    <p>Acids</p> Signup and view all the answers

    Which hazard is associated with vehicle fires?

    <p>Exploding bumpers and tires.</p> Signup and view all the answers

    What is the main purpose of the unit regarding Master Streams for BFD personnel?

    <p>To inform about the benefits and dangers of Master Streams.</p> Signup and view all the answers

    Why is personal safety emphasized during operations involving Master Streams?

    <p>They can produce a greater force that could harm personnel.</p> Signup and view all the answers

    What natural factor can be utilized to increase the vertical reach of a fire stream?

    <p>Head Wind</p> Signup and view all the answers

    Which nozzle pressure is recommended for a solid stream?

    <p>80 psi</p> Signup and view all the answers

    What is one of the primary advantages of using a straight stream during firefighting?

    <p>More water delivery with greater punch</p> Signup and view all the answers

    What characteristic of fog streams helps reduce risk to exposures?

    <p>Creation of a water curtain</p> Signup and view all the answers

    How can tail winds affect the effectiveness of a master stream?

    <p>Increase horizontal range</p> Signup and view all the answers

    What should firefighters be particularly cautious of when using solid streams?

    <p>Projectile risks from debris</p> Signup and view all the answers

    Which factor contributes to the arc or curve of a fire stream?

    <p>Gravity</p> Signup and view all the answers

    In what scenario would fog streams be particularly beneficial?

    <p>Cooling down hot structures</p> Signup and view all the answers

    Study Notes

    Rescue Team Procedures

    • Rescue Company follows the same procedures as Truck Company when splitting into two teams, but one team has three members
    • Radio designations are “Rescue” and “Rescue Alpha”

    Back Up Team

    • Before any team enters a hot zone, a two-person back up team must be in place
    • Back up team must be fully equipped and ready to assist the entry team
    • Back up team cannot be performing other essential duties at the time they are standing by
    • Back up team exception: immediate action must be taken to save a life or prevent serious injury

    Second Ladder Company

    • Position apparatus in a non-committed area
    • Report to the Incident Commander as one team
    • Report with proper tool selection for the assignment

    Crew Assignment for Second Ladder Company

    • Roof ventilation is the #1 priority
    • Additional forcible entry requirements
    • Supplement ventilation needs: expand horizontal ventilation, vertical ventilation of roof
    • Check exposures for extension
    • Check for hidden fire
    • General overhaul and salvage duties
    • Check utilities

    Universal Considerations for Ladder Companies

    • Report to the Incident Commander for orders
    • Apparatus placement for aerial work must be considered
    • Flat roof operations
    • Ladder company should be part of the truck company size-up
    • If aerial is to be used a member must be at the turntable and the pump panel
    • Thermal imaging camera will be deployed at all structure fires
    • Report to Incident Commander/Accountability Officer any change in floor level within a structure
    • Report in/out of structure through Command Post/Accountability Officer
    • Keep crew intact, Officer is to know where each member of the crew is
    • Additional incoming truck companies shall stage and wait for orders
    • General tool selection must reflect the assignment and type of structure

    Parking Guidelines

    • Park uphill, upwind
    • Stay out of spills, from under wires, out of smoke
    • For hazardous cargo, use D.O.T. guidelines for suggested zones

    Dispatch Notification

    • Situation found, actions being taken
    • Additional resources needed
    • Notifications i.e. police, State troopers, power company, EMS

    Engine Company Fire Attack

    • Hose Stretch - Minimum of 100’ of 1¾” hose
    • Stream Use - Depending on conditions, stream should initially be operated from an extended range and slowly worked in
    • Forcible Entry / Overhaul - May be needed to open doors, trunk, cargo area
    • Alternate extinguishing agents can be used

    Termination of Engine Company Fire Attack

    • Collect and record all pertinent information
    • Secure area
    • Terminate Command
    • Return to quarters, Truck Officer to do paper work

    Vehicle Fire General Safety Issues

    • Establish a safety zone
    • Protective gear
    • Potential Dangers: traffic, fuel tanks, alternate fuels, exploding of bumpers, struts, shocks, batteries, tires, hazardous cargo

    Master Streams

    • Master Streams include Ladder Pipes, Blitzfire Monitors and fixed Turrets on Engines
    • Master Streams are used in circumstances where smaller hand lines are not sufficient
    • Master Streams are used in defensive operations
    • No master stream shall be introduced into a structure where interior firefighting operations are being performed!

    Master Stream Purpose

    • To make BFD personnel aware of the benefits and inherent dangers of the use of Master Streams

    Master Stream Definition

    • Master Streams are heavy caliber hose streams using fixed/portable appliances rated at 400-1000+ GPM

    Master Stream Vertical Reach

    • Streams can be directed into upper floors of multi-storied buildings
    • Can penetrate into floor areas when used at the proper angle

    Factors Affecting Master Streams

    • Gravity creates a natural arc
    • Tail Wind increases horizontal range
    • Head Wind increases vertical reach
    • Proper pressure at the tip

    Solid Stream Benefits

    • Solid streams deliver more water with greater punch power
    • Solid streams can tear apart a building and perform “Hydraulic Overhaul”
    • Solid stream can also cause serious damage to anything in its path, including exposure buildings and their components

    Fog Stream Benefits

    • Fog stream creates a water curtain to protects exposures and buildings in danger
    • Fog stream can be used to cool a Storage Tank from a distance
    • Fog stream has limitations that should be noted

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    Description

    Test your knowledge on rescue team procedures, backup team requirements, and the operations of a second ladder company. This quiz covers critical protocols and safety measures essential for effective incident management in emergency situations.

    More Like This

    Rescue Team Responsibilities
    7 questions

    Rescue Team Responsibilities

    ConvenientChocolate266 avatar
    ConvenientChocolate266
    Mine Rescue Team Standard Search Procedures
    30 questions
    Procedure 303 Rapid Intervention/Two-in Two-Out
    18 questions
    Use Quizgecko on...
    Browser
    Browser