Range of Motion and Flexibility Testing Quiz

HarmlessGyrolite4817 avatar
HarmlessGyrolite4817
·
·
Download

Start Quiz

Study Flashcards

66 Questions

What is the primary reason for including flexibility tests in health-related fitness batteries?

To assess the association between lack of flexibility and musculoskeletal injuries

What does the limited evidence suggest about the relationship between flexibility and injury risk?

Greater than normal flexibility may not necessarily decrease injury risk

What is the ability of a joint, or series of joints, to move through a full range of motion without injury called?

Flexibility

Who is suggested to be at a higher risk for musculoskeletal injuries based on flexibility research?

Individuals with ankylosis or hypermobility

Which test assesses low back flexibility by measuring lumbar ROM directly?

Double-Inclinometer Technique

What is the primary purpose of the Chair Sit-and-Reach Test?

Assess lower body (hamstring) flexibility

Which muscle group is responsible for stabilizing the lumbar spine and is measured by the Sorensen Test?

Trunk extensors (erector spinae)

What does the Skin Distraction Test assess?

Low back flexibility

Which test is intended for individuals with functional limitations preventing them from performing sit-and-reach tests on the floor?

Back-Saver Sit-&-Reach Test

What is the relative zero point established for in the Modified Sit-and-Reach Test?

Each client

Which test measures lumbar ROM indirectly?

Modified Schober Test & Skin Distraction Test

What does the V-Sit Test measure?

Isometric endurance of trunk flexors

Which device is used to measure range of motion (ROM) at the elbow joint using a weighted 360-degree dial and pointer?

Leighton Flexometer

Which method is considered the best reference method for establishing the validity of goniometric measurements?

Radiography

Which type of joint measurements are generally more reliable according to the text?

Upper extremity joint measurements

Which test is included in most health-related fitness test batteries due to the belief that lack of flexibility is associated with low back pain and musculoskeletal injuries?

Sit-and-reach test

What does the sit-and-reach test provide an indirect, linear measurement of?

ROM of the lower back and hamstring muscles

What does research indicate about the validity of the sit-and-reach test?

It is not a valid measure of low back and hamstring flexibility

What is the CSEP sit-and-reach test protocol based on?

Age and gender

Which type of sit-and-reach tests are available to account for limb-length differences and discomfort during testing?

Modified sit-and-reach tests

What is the advantage of electrogoniometers over traditional goniometers and digital goniometers?

Flexibility

What is the advantage of inclinometers over traditional goniometers and digital goniometers?

Do not require alignment with specific bony landmarks

What is the main factor affecting the validity and reliability of direct measures of ROM?

Joint being measured and technician skill

Which joint measurements have variable intertester reliability according to the text?

Lumbar extension and subtalar joint measurements

What does static flexibility measure?

The total range of motion (ROM) at a joint

What affects both static and dynamic flexibility?

Muscle-tendon unit and viscoelastic properties

What is a factor affecting flexibility according to the text?

Warm-up

What limits flexibility according to the text?

Muscle-tendon unit

What is age-related flexibility loss attributed to?

Development of arthritic conditions

What is the primary determinant of flexibility according to the text?

Habitual movement patterns

What affects joint range of motion?

Joint classification

What affects dynamic flexibility?

Muscle-tendon unit

What is a factor influencing the muscle-tendon unit?

Viscoelastic properties

What do females generally have more than males according to the text?

Flexibility

What affects the muscle-tendon unit?

Viscoelastic properties

What is a factor affecting joint range of motion according to the text?

Joint geometry

Which of the following statements best summarizes the research findings on the relationship between flexibility and injury risk?

There is limited evidence supporting the idea that greater flexibility reduces injury risk.

What does the term 'flexibility' refer to?

The ability of a joint, or series of joints, to move through a full range of motion without injury.

What is the primary reason for including flexibility tests in health-related fitness batteries?

Due to the belief that lack of flexibility is associated with musculoskeletal injuries & low back pain.

What does the term 'hypermobility' refer to in the context of flexibility research?

A condition where joints have excessive flexibility.

What are flexibility and joint stability highly dependent on?

The strength of ligaments spanning the joint.

What is the primary determinant of flexibility according to the text?

Joint structure.

What does research indicate about the association between lumbar or hamstring flexibility and low back pain?

The association between lumbar or hamstring flexibility and low back pain is inconclusive.

Which test is intended for many older individuals with functional limitations preventing them from performing sit-and-reach tests on the floor?

Modified Back-Saver Sit-and-Reach Test

What is the primary muscle group responsible for stabilizing the lumbar spine and is measured by the Sorensen Test?

Trunk extensors (erector spinae)

Which test assesses upper body (shoulder joint) flexibility?

Back Scratch Test

What is the relative zero point established for in the Modified Sit-and-Reach Test?

Each client

Which test measures lumbar ROM indirectly?

Modified Schober Test & Skin Distraction Test

What is the primary reason for including flexibility tests in health-related fitness batteries?

To assess overall functional fitness

What does the Skin Distraction Test assess?

Low back flexibility

What is the advantage of inclinometers over traditional goniometers and digital goniometers?

They provide a more direct measurement of ROM

What is the primary determinant of flexibility according to the text?

Muscle elasticity and length

What is the primary factor limiting static flexibility?

Tendon extensibility

Which factor contributes differently to the total resistance encountered during movement?

Muscle

What is the primary determinant of flexibility according to the text?

Body type

What is the main reason for females generally being more flexible than males?

Pelvic structure differences

What is the effect of viscoelastic stress relaxation on muscle stiffness?

Decreases muscle stiffness

What is the primary factor affecting joint range of motion?

Muscle-tendon tension

What is the primary factor affecting the total resistance encountered during movement?

Muscles

What is the reliability coefficient for intertester reliability of lumbar extension measurements using inclinometers?

0.48

Which equipment is specifically used for measuring elbow joint range of motion?

Leighton Flexometer

What is the primary advantage of inclinometers over flexometers and universal goniometers?

They don't require alignment with specific bony landmarks

What is the best reference method for establishing the validity of range of motion measurements?

Radiography

What is the primary reason for including the Sit-and-Reach Test in health-related fitness test batteries?

Belief that lack of flexibility is associated with low back pain and musculoskeletal injuries

What does research indicate about the validity of the Sit-and-Reach Test?

It lacks validity and is unrelated to self-reported back pain

What is the primary focus of the CSEP Sit-and-Reach Test Protocol?

Specific warm-up and measurement instructions

Study Notes

Measuring Range of Motion and Flexibility Testing

  • Electrogoniometers have advantages over traditional goniometers and digital goniometers, such as flexibility and hands-free use.
  • Leighton Flexometer is a device used to measure range of motion (ROM) at the elbow joint using a weighted 360-degree dial and pointer.
  • Inclinometers, another gravity-dependent goniometer, are easier to use and do not require alignment with specific bony landmarks.
  • Validity and reliability of direct measures of ROM are highly dependent on the joint being measured and technician skill.
  • Radiography is considered the best reference method for establishing the validity of goniometric measurements.
  • Upper extremity joint measurements are generally more reliable than lower extremity joint measurements.
  • Inclination measurements have variable intertester reliability, with lumbar extension and subtalar joint showing different reliability coefficients.
  • The sit-and-reach test is included in most health-related fitness test batteries due to the belief that lack of flexibility is associated with low back pain and musculoskeletal injuries.
  • The sit-and-reach test provides an indirect, linear measurement of the ROM and is used to evaluate the static flexibility of the lower back and hamstring muscles.
  • Research indicates that the sit-and-reach test is not a valid measure of low back and hamstring flexibility and is unrelated to self-reported back pain.
  • The CSEP sit-and-reach test protocol involves a warm-up, specific measurement instructions, and a health benefit rating based on age and performance.
  • Different types of sit-and-reach tests and equipment are available, including modified versions to account for limb-length differences and discomfort during testing.

Flexibility and Joint Range of Motion in Exercise Science (EXCI 252)

  • Static flexibility measures the total range of motion (ROM) at a joint and is limited by the extensibility of the musculotendinous unit.
  • Dynamic flexibility measures the rate of torque developed during stretching throughout the ROM.
  • Joint range of motion depends on morphological factors such as joint geometry, joint capsule, ligaments, tendons, and muscles.
  • Joint classification is based on structure and function, including gliding, hinge, pivot, condyloid & saddle, and ball & socket joints.
  • Soft tissue structures that limit flexibility include joint capsule, muscle & its fascia, tendons & ligaments, and skin.
  • The muscle-tendon unit affects both static and dynamic flexibility and is influenced by viscoelastic properties and muscular contraction.
  • Elastic and viscous deformation of the muscle-tendon unit occur during stretching, affecting tension and muscle stiffness.
  • Factors affecting flexibility include body type, age, gender, physical activity level, warm-up, and amount of stretching & flexibility training.
  • Bodybuilders and obese individuals may score poorly on ROM tests due to large hypertrophied muscles or excessive subcutaneous fat.
  • Age-related flexibility loss is attributed to increased muscle stiffness, lower stretch tolerance, decline in physical activity, and development of arthritic conditions.
  • Females are generally more flexible than males, attributed to gender differences in pelvic structure and hormones affecting connective tissue laxity.
  • Habitual movement patterns, lack of physical activity, disuse, and warm-up are important determinants of flexibility, affecting ROM and muscle tissue.

Measuring Range of Motion and Sit-and-Reach Test Protocols

  • Electrogoniometers offer flexibility and hands-free usage, allowing for simultaneous measurements in 2 planes with a 2-channel electrogoniometer.
  • Leighton Flexometer measures joint ROM using a weighted 360-degree dial and pointer, specifically used for elbow joint ROM.
  • Inclinometers measure the angle between the moving segment's long axis and the line of gravity, with the double inclinometer technique used for lumbosacral flexion.
  • Inclinometers are easier to use than flexometers and universal goniometers, as they don't require alignment with specific bony landmarks.
  • Validity and reliability of ROM measurements are highly dependent on the joint being measured and technician skill, with radiography considered the best reference method.
  • Goniometric measurements' reliability is affected by difficulty in identifying the axis of rotation and palpating bony landmarks, with upper extremity joint measurements generally more reliable than lower extremity joint measurements.
  • Intertester reliability of inclinometer measurements varies by joint, such as lumbar extension (reliability coefficient = 0.48) and subtalar joint (reliability coefficient = 0.96).
  • Accurate and reliable ROM measurements require knowledge of anatomy, standardized testing procedures, and training and practice.
  • The Sit-and-Reach Test is commonly included in health-related fitness test batteries due to the belief that lack of flexibility is associated with low back pain and musculoskeletal injuries.
  • The Sit-and-Reach Test provides an indirect measurement of lower back and hamstring muscle flexibility, but research indicates it lacks validity and is unrelated to self-reported back pain.
  • The CSEP Sit-and-Reach Test Protocol includes specific warm-up and measurement instructions, with a scoring system based on age and gender.
  • Various Sit-and-Reach Test equipment and modifications, such as the Modified Back-Saver, are available to account for limb-length differences and relieve discomfort during testing.

Test your knowledge of range of motion (ROM) and flexibility testing with this quiz. Explore different measurement devices, factors influencing flexibility, and the relationship between flexibility and exercise science. Keywords: range of motion, flexibility testing, goniometers, joint measurements, sit-and-reach test, musculoskeletal injuries, dynamic flexibility, soft tissue structures, muscle-tendon unit, factors affecting flexibility.

Make Your Own Quizzes and Flashcards

Convert your notes into interactive study material.

Get started for free
Use Quizgecko on...
Browser
Browser