quiz image

Railway Track Clearances and Structures

SolicitousOklahomaCity avatar
SolicitousOklahomaCity
·
·
Download

Start Quiz

Study Flashcards

19 Questions

What is the minimum horizontal distance from the centre of the track to any structure between 305mm to 3355mm above rail level?

2135mm

What is the exception to the minimum horizontal distance from the centre of the track to any structure below the rail level and up to formation level of the track?

Bridges and tunnels

What is the minimum horizontal distance from the centre of the track to any structure from 4115mm to 6100mm above rail level on lines other than main lines or existing main lines?

1370mm

What is the minimum horizontal distance from the centre of the track to any structure at and above formation level up to rail level in case of electrification works in existing yards on curves having radius less than 875m?

2510mm

What is the minimum horizontal distance from the centre of the track to any structure from rail level to 305mm above rail level?

1675mm

What is the minimum horizontal distance from the centre of the track to any structure below the rail level and up to formation level of the track on curves with radius less than 875m?

2725mm

What is the minimum horizontal distance from the centre of the track to any structure at and above formation level up to rail level in case of electrification works in existing yards on straight tracks?

2360mm

What is the minimum horizontal distance from the centre of the track to any structure from 3355mm to 4115mm above rail level?

2135mm

What is the minimum horizontal distance from the centre of the track to any structure below the rail level and up to formation level of the track on straight tracks?

2575mm

What is the minimum horizontal distance required from rail level to 305mm above rail level for new works or alterations to existing works?

1905mm

Up to what height above rail level is the horizontal distance of 2360mm applicable?

3735mm

What is the minimum horizontal distance required from 4420mm to 4610mm above rail level?

2135mm

What is the minimum horizontal distance required below the rail level and up to the formation level of the track on curves with a radius less than 875m?

2725mm

What is the exception to the minimum horizontal distance requirements for items (vii) and (viii)?

All of the above

What is the minimum horizontal distance required for addition/alteration to works in existing yards on curves with a radius less than 875m?

2510mm

What is the clearance requirement for fixtures attached to the track like traction bonds?

There is no specific clearance requirement for these fixtures

What is the purpose of the note in the clearance requirements?

To refer to the appendix for extra clearances required on curves

What is the horizontal distance required from 4610mm to 6250mm above rail level?

1600mm

What is the significance of the 875m radius in the clearance requirements?

It is the radius at which the clearance requirements change

Study Notes

Minimum Horizontal Distance from Centre of Track to Any Structure

  • For existing works, the minimum horizontal distance from centre of track to any structure varies with height above rail level:
    • From rail level to 305mm above rail level: 1675mm
    • From 305mm to 3355mm above rail level: 2135mm
    • From 3355mm to 4115mm above rail level: 2135mm decreasing to 1980mm
    • From 4115mm to 6250mm above rail level: 1600mm
    • Below rail level and up to formation level of the track: 2575mm (straight and curves up to radius of 875m) or 2725mm (curves with radius less than 875m)

Exceptions and Special Cases

  • For lines other than main lines or existing main lines where electric traction is not likely to be introduced, the horizontal distance of 1370mm for height from 4115mm to 6100mm above rail level may be allowed to continue
  • Certain fixtures attached to the track, such as lock bars, point machines, traction bonds, and signal rodding, are exempt from clearance requirements
  • In electrification works in existing yards, no foundation, mast, signal post, or other structure shall be provided between two tracks, unless it is unavoidable, in which case the minimum distance from the centre of track shall be 2360mm (straight track and curves with radius of 875m or more) or 2510mm (curves with radius less than 875m)

New Works or Alterations to Existing Works

  • The minimum horizontal distance from centre of track to any structure varies with height above rail level:
    • From rail level to 305mm above rail level: 1905mm
    • From 305mm to 1065mm above rail level: 1905mm increasing to 2360mm
    • From 1065mm to 3735mm above rail level: 2360mm
    • From 3735mm to 4420mm above rail level: 2360mm decreasing to 2135mm
    • From 4420mm to 4610mm above rail level: 2135mm decreasing to 1980mm
    • From 4610mm to 6250mm above rail level: 1600mm
    • Below rail level and up to formation level of the track: 2575mm (straight and curves up to radius of 875m) or 2725mm (curves with radius less than 875m)

Additional Notes

  • See appendix for extra clearances required on curves
  • Certain structures, such as bridges, tunnels, and ballastless track (including washable apron), are exempt from clearance requirements

This quiz tests your knowledge of minimum horizontal distances between railway tracks and various structures, including existing works and formations.

Make Your Own Quizzes and Flashcards

Convert your notes into interactive study material.

Get started for free

More Quizzes Like This

Railway Curve Alignment and Cant Design
40 questions
Railway Engineering: Cant on Curved Tracks
40 questions
Railway Engineering: Track Design
23 questions
Use Quizgecko on...
Browser
Browser