Radiation Protection: Gonadal Shielding and AEC Systems
18 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

Which technique helps reduce patient exposure in radiography?

  • Increasing the focal spot-to-image receptor distance
  • Using a lower X-ray tube voltage
  • Taking multiple images of the same region
  • Using an anti-scatter grid or air gap (correct)
  • What is the purpose of taking a preliminary image before a series of images?

  • To test the anti-scatter grid
  • To adjust the X-ray tube voltage
  • To confirm the correctness of settings and avoid retakes (correct)
  • To check the X-ray equipment's functioning
  • What is the purpose of an AEC device in radiography?

  • To increase the X-ray tube voltage
  • To adjust the focal spot-to-image receptor distance
  • To reduce irradiations and repeat irradiations to a minimum (correct)
  • To improve image resolution
  • When should the use of automatic exposure control be limited?

    <p>During thoraco-abdominal examinations</p> Signup and view all the answers

    What is the purpose of the operator evaluating the resulting images?

    <p>To verify diagnostic quality images and correct X-ray equipment functioning</p> Signup and view all the answers

    What is the benefit of using the highest X-ray tube voltage that produces good quality images?

    <p>It produces images of good quality while minimizing patient exposure</p> Signup and view all the answers

    What could be a possible cause of ROI underexposure in AEC related to ionization chambers?

    <p>Small anatomical areas imaged without full coverage by the chamber</p> Signup and view all the answers

    What could mitigate ROI underexposure when the ionization chamber is beneath a structure with higher tissue density in AEC?

    <p>Repositioning the patient to center the ROI over the ionization chamber</p> Signup and view all the answers

    What is the main contributor to ROI overexposure related to AEC?

    <p>Artifacts or prostheses with low atomic mass within the ROI</p> Signup and view all the answers

    In the context of AEC, how can one address premature exposure cut-off resulting from excessive scatter radiation reaching the ionization chambers?

    <p>Closing collimation for better scatter control</p> Signup and view all the answers

    What could lead to ROI underexposure in AEC when imaging a small anatomical area?

    <p>Not using AEC and resorting to manual techniques</p> Signup and view all the answers

    What is the primary way to ensure proper termination of radiographic exposure in AEC systems?

    <p>Keen understanding of AEC functioning</p> Signup and view all the answers

    What type of crystal is commonly used in solid state radiation detectors?

    <p>Silicon</p> Signup and view all the answers

    What is a primary advantage of using solid state radiation detectors over gas detectors?

    <p>Higher sensitivity</p> Signup and view all the answers

    Which component in radiographic units displays the actual amount of mAs used for an image?

    <p>mAs readout display</p> Signup and view all the answers

    How does knowledge of the mAs readout benefit a medical imaging technologist (MIT)?

    <p>Facilitates manual exposure technique adjustments</p> Signup and view all the answers

    In what position may Automatic Exposure Control (AEC) and manual technique be combined due to centering difficulties?

    <p>AP lumbar spine</p> Signup and view all the answers

    Why are solid state radiation detectors preferred over photocells in radiography?

    <p>Higher accuracy</p> Signup and view all the answers