Proposed Electronics Equipments for Freight Stock
90 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the maximum weight measurement capacity of the EIMWB?

  • 100 T
  • 150 T
  • 120 T (correct)
  • 110 T
  • Which standard governs the weighment on the EIMWB?

  • ISO 9001
  • IEEE 802.3
  • OIML R -106 (correct)
  • ASTM D-100
  • What is the minimum scale interval of the EIMWB?

  • 200 kg
  • 50 kg
  • 75 kg
  • 100 kg (correct)
  • Which equipment is NOT part of the Guard Comfort kit?

    <p>Generator</p> Signup and view all the answers

    What is the power consumption limit for the fans used in guard vans?

    <p>30 W</p> Signup and view all the answers

    What type of light fitting is prescribed for guard vans?

    <p>LED</p> Signup and view all the answers

    What is the minimum wattage for the roof-mounted light in the Guard Comfort kit?

    <p>15 W</p> Signup and view all the answers

    What arrangement is specified for the fan fittings in guard vans?

    <p>Wall mounted with manual/auto swivel arrangement</p> Signup and view all the answers

    What essential feature is required for the solar PV module in the guard vans?

    <p>Pilferage proof</p> Signup and view all the answers

    Where are guard vans primarily located in freight trains?

    <p>As last vehicles in freight trains</p> Signup and view all the answers

    What is the primary function of the EOTT system?

    <p>To monitor brake pipe pressure and facilitate braking from the rear of the train</p> Signup and view all the answers

    Where is the CDU unit installed?

    <p>In the driver cabin</p> Signup and view all the answers

    What is one of the monitoring capabilities of the EOTT system?

    <p>Distance measurements in reference to the locomotive</p> Signup and view all the answers

    Which component of the EIMWB is responsible for detecting speed and wagon type?

    <p>Track switches/sensors</p> Signup and view all the answers

    What is the maximum speed at which the Electronic In Motion Weighbridge operates?

    <p>15 kmph</p> Signup and view all the answers

    What type of alarm is included in the EOTT system to enhance safety?

    <p>Low pressure alarm for the last vehicle</p> Signup and view all the answers

    The SBU component of EOTT is connected to which part of the train?

    <p>Rear coupler of the last vehicle</p> Signup and view all the answers

    How does the CDU receive information from the SBU?

    <p>Through Radio Frequency communication</p> Signup and view all the answers

    What is one of the primary purposes of the EIMWB?

    <p>To check for overloading in wagons</p> Signup and view all the answers

    What type of facility does the EOTT system provide for documentation?

    <p>Data logging facilities</p> Signup and view all the answers

    What is the primary purpose of installing RFID tags on freight stock?

    <p>To enable automatic wagon identification</p> Signup and view all the answers

    What capacity should the Solar PV module have according to the specifications?

    <p>Capable of continuous operation for at least 12 hours</p> Signup and view all the answers

    What feature is important for the security of the Solar PV module and its components?

    <p>Anti-pilferage devices</p> Signup and view all the answers

    What type of maintenance shift does the implementation of RFID tags encourage?

    <p>From periodic to predictive maintenance</p> Signup and view all the answers

    Which of the following components is NOT specified as part of the Solar PV module's requirements?

    <p>Air conditioning unit</p> Signup and view all the answers

    How does RFID technology improve the operations related to freight wagons?

    <p>By automating the identification process</p> Signup and view all the answers

    Which of the following statements about the switches on the switch board is accurate?

    <p>The switch board incorporates switches for lights and fans</p> Signup and view all the answers

    What is a common outcome of using RFID tags in wagon operations?

    <p>Automatic determination of wagon consist</p> Signup and view all the answers

    What is one of the necessary components of a self-contained modular unit in a solar system?

    <p>A battery</p> Signup and view all the answers

    What type of installation is preferred for the solar PV module and its components?

    <p>A self-contained modular unit suitable for specified locations</p> Signup and view all the answers

    Which of the following functions is NOT performed by the EOTT system?

    <p>Data logging of train speeds</p> Signup and view all the answers

    What is the primary technological method used for connection between CDU and SBU in the EOTT system?

    <p>Radio Frequency communication</p> Signup and view all the answers

    Which of the following components is part of the Electronic In Motion Weighbridge system?

    <p>Weigh rails of length 5.5 m</p> Signup and view all the answers

    What is the maximum operating speed of the EIMWB during weight measurement?

    <p>15 kmph</p> Signup and view all the answers

    Which of the following is a feature of the SBU in the EOTT system?

    <p>It connects to the last vehicle BP hose pipe</p> Signup and view all the answers

    What type of alarm is included in the EOTT system for real-time monitoring?

    <p>Low pressure alarm</p> Signup and view all the answers

    Which component of the EIMWB directly links to the control console for weight data processing?

    <p>Weigh sensors</p> Signup and view all the answers

    Which of the following is NOT a function of the CDU in the EOTT system?

    <p>Calculating weight of freight stock</p> Signup and view all the answers

    What is the primary risk the EIMWB aims to mitigate in freight operations?

    <p>Overloading of freight wagons</p> Signup and view all the answers

    Which of the following is an advantage of using the EOTT system over traditional methods?

    <p>It enables simultaneous braking from the rear of the train</p> Signup and view all the answers

    What additional facility is aimed to be provided inside guard vans through the Guard Comfort kit?

    <p>Mobile charging facility</p> Signup and view all the answers

    Which technical requirement is associated with the LED light fitting in the Guard Comfort kit?

    <p>10W minimum for table mounted lights</p> Signup and view all the answers

    What is a key advantage of implementing RFID tags on freight wagons?

    <p>Reduction in manual labor for wagon inspections</p> Signup and view all the answers

    Which aspect is NOT required for the Solar PV module as specified?

    <p>It must be capable of operating continuously for 24 hours</p> Signup and view all the answers

    What is one requirement for the fan fittings specified in the Guard Comfort kit?

    <p>Must allow manual and automatic swivel adjustment</p> Signup and view all the answers

    What shift in maintenance practices does the use of RFID tags promote?

    <p>From periodic maintenance to predictive maintenance</p> Signup and view all the answers

    What security feature is emphasized for the Solar PV module in the Guard Comfort kit?

    <p>Anti-pilferage arrangement</p> Signup and view all the answers

    Which component is essential for the installation of the self-contained modular unit of the solar system?

    <p>All associated accessories are essential</p> Signup and view all the answers

    What is the maximum power consumption specified for the fans in the Guard Comfort kit?

    <p>30W</p> Signup and view all the answers

    What is the primary function of an RFID tag in the context of freight wagons?

    <p>To facilitate automatic wagon identification</p> Signup and view all the answers

    What purpose does the RDSO specification WD-29-Misc-05 serve?

    <p>Lays down technical requirements for electronic weigh bridges</p> Signup and view all the answers

    Which of the following is a necessary feature for the Solar PV module and its components?

    <p>They should include theft deterrent mechanisms</p> Signup and view all the answers

    Which feature of the light fitting specifies its energy efficiency in the Guard Comfort kit?

    <p>Incorporates LED technology</p> Signup and view all the answers

    Where primarily are guard vans located in the train configuration?

    <p>Among the freight wagons</p> Signup and view all the answers

    When did Indian Railways mandate the provision of RFID tags on wagons?

    <p>2016</p> Signup and view all the answers

    What secondary benefit does RFID tag implementation provide besides automatic identification?

    <p>Facilitates in-motion weighing and diagnostics</p> Signup and view all the answers

    What are the specifications for the wall-mounted fan fittings in guard vans?

    <p>8” (Min) with power consumption of 30 W</p> Signup and view all the answers

    What is the minimum wattage required for roof-mounted light fittings in the Guard Comfort kit?

    <p>15W</p> Signup and view all the answers

    Which of the following options accurately describes a component of the solar PV module's setup?

    <p>Includes connectors and junction boxes</p> Signup and view all the answers

    How does the implementation of RFID tags affect traditional maintenance methods?

    <p>It facilitates a move from periodic to predictive maintenance</p> Signup and view all the answers

    What is the minimum wattage for the table-mounted LED light in the Guard Comfort kit?

    <p>10 W</p> Signup and view all the answers

    What type of fans are specified to be used in guard vans according to the requirements?

    <p>Wall Mounted</p> Signup and view all the answers

    Which functional requirement is associated with the battery in the Guard Comfort kit?

    <p>Must support mobile charging</p> Signup and view all the answers

    What is the maximum power consumption allowed for the fan fittings specified for guard vans?

    <p>30 W</p> Signup and view all the answers

    Which aspect of the Solar PV module is emphasized for security purposes?

    <p>Anti-pilferage arrangement</p> Signup and view all the answers

    What is the minimum wattage for the roof-mounted LED light fitting in the Guard Comfort kit?

    <p>15 W</p> Signup and view all the answers

    What type of fitting is required for the light inside guard vans?

    <p>LED</p> Signup and view all the answers

    Which of the following is NOT a specified requirement for fan fittings in guard vans?

    <p>Remote-controlled operation</p> Signup and view all the answers

    Where are guard vans typically located in freight trains?

    <p>Last vehicles</p> Signup and view all the answers

    Which minimum size is specified for the fans used in the Guard Comfort kit?

    <p>8 inches</p> Signup and view all the answers

    What is the primary advantage of the EOTT system over traditional methods for freight monitoring?

    <p>Real-time monitoring of brake pressure</p> Signup and view all the answers

    Which unit of the EOTT system is installed in the driver's cabin?

    <p>CDU</p> Signup and view all the answers

    What is one of the tasks performed by the SBU in the EOTT system?

    <p>Sending radio signals at regular intervals</p> Signup and view all the answers

    What is the maximum speed at which the EIMWB operates during weight measurement?

    <p>15 km/h</p> Signup and view all the answers

    What type of information does the CDU display in the EOTT system?

    <p>Brake pipe pressure and related data</p> Signup and view all the answers

    Which component of the EIMWB is essential for detecting the type of wagon?

    <p>Track switches/sensors</p> Signup and view all the answers

    Which function is NOT part of the EOTT system?

    <p>Train speed monitoring</p> Signup and view all the answers

    What is the purpose of the EIMWB in relation to freight wagons?

    <p>To check for overloading</p> Signup and view all the answers

    What type of alarm does the EOTT system have to ensure safety?

    <p>Loss of communication alarm</p> Signup and view all the answers

    Which of the following components is included in the EIMWB system?

    <p>Control console with electronic cards</p> Signup and view all the answers

    What is the purpose of RFID tags on freight stock?

    <p>To facilitate automatic identification and tracking of wagons</p> Signup and view all the answers

    Which component is NOT specified as part of the solar PV module's requirements?

    <p>Portable charger</p> Signup and view all the answers

    What type of maintenance shift does the implementation of RFID tags encourage?

    <p>Predictive maintenance</p> Signup and view all the answers

    What essential feature is required for the solar PV module in the guard vans?

    <p>Anti-pilferage devices</p> Signup and view all the answers

    Which of the following functions is NOT performed by the EOTT system?

    <p>Manual identification of wagons</p> Signup and view all the answers

    Which component is essential for the installation of the self-contained modular unit of the solar system?

    <p>Switch gears</p> Signup and view all the answers

    What is a key advantage of implementing RFID tags on freight wagons?

    <p>Increased efficiency in wagon identification</p> Signup and view all the answers

    What feature is important for the security of the solar PV module and its components?

    <p>Anti-pilferage devices</p> Signup and view all the answers

    What is the primary function of the RFID tag reader?

    <p>To identify and read data from RFID tags</p> Signup and view all the answers

    What should the solar PV module be capable of to fulfill its role?

    <p>Operating continuously for a minimum of 12 hours</p> Signup and view all the answers

    Study Notes

    Proposed Electronics Equipments for Freight Stock

    • Proposed equipment for freight stock safety and better utilization by RDSO
    • EOTT (End of Train Telemetry)
      • Alternative to Guard and Brake van
      • Monitors brake pipe pressure in the last train car
      • Allows driver to apply brakes simultaneously from rear
      • Consists of CDU (Communication Display Unit) and SBU (Sense and Braking Unit)
      • CDU in driver's cabin, SBU on last car's coupler
      • Connects SBU to last car's brake pipe
      • CDU displays last car's brake pressure and other data
      • Radio frequency communication (406.5 MHz)
      • Functions include distance measurement, last car pressure monitoring, low pressure alarm, motion status, marker light status, battery status, communication loss alarm, automatic and manual communication test, train emergency app, service braking from rear, and data logging
    • EIMWB (Electronic In Motion Weighbridge)
      • Measures freight stock gross weight during motion (up to 15 kmph)
      • Checks for overloading
      • Weigh rails (5.5m)
      • Track switches/sensors for speed and wagon type
      • Control console with electronic cards for signal processing
      • Personal computer and printer for viewing and printing
      • Measures up to 120 tonnes with 100 kg interval
    • Guard Comfort Kit (Solar PV module with fittings)
      • Designed for guard vans (last freight cars)
      • No power source currently installed
      • Solar PV module with fittings installed in Brake Vans
    • RFID Tags
      • Automatic wagon identification using Radio Frequency Identification (RFID)
      • Indian Railways mandates RFID tags on wagons since 2016
      • Eliminates manual number taking

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    Description

    Explore the innovative electronic equipment proposed for the safety and efficiency of freight stock as outlined by RDSO. This quiz covers key technologies like EOTT and EIMWB, detailing their functionalities, integration, and benefits for railway operations.

    More Like This

    Tipos de material remolcado: coches y vagones
    10 questions
    Freight Stock Maintenance POH & IOH
    82 questions
    Wagon Stock Inspection Checklists
    81 questions
    Use Quizgecko on...
    Browser
    Browser