What is the primary responsibility of the fire department when a gas leak occurs?
What is the primary responsibility of the fire department when a gas leak occurs?
How should personnel move inside a building with a suspected gas leak?
How should personnel move inside a building with a suspected gas leak?
What is the appropriate action if gas monitors inside a building detect gas?
What is the appropriate action if gas monitors inside a building detect gas?
What should be done with potential ignition sources during a gas leak situation?
What should be done with potential ignition sources during a gas leak situation?
Signup and view all the answers
What is the minimum number of personnel that should enter a hot zone during a gas leak?
What is the minimum number of personnel that should enter a hot zone during a gas leak?
Signup and view all the answers
Who is responsible for controlling the gas leak once the gas company personnel arrive?
Who is responsible for controlling the gas leak once the gas company personnel arrive?
Signup and view all the answers
What should be done with buildings having gas accumulation?
What should be done with buildings having gas accumulation?
Signup and view all the answers
What is the fire department required to do before leaving the scene of a gas leak?
What is the fire department required to do before leaving the scene of a gas leak?
Signup and view all the answers
What is the first action to take upon arrival at the scene of a natural gas leak?
What is the first action to take upon arrival at the scene of a natural gas leak?
Signup and view all the answers
Which zone is established around a gas leak area that is the most hazardous?
Which zone is established around a gas leak area that is the most hazardous?
Signup and view all the answers
What protective equipment must personnel wear while in the hot zone?
What protective equipment must personnel wear while in the hot zone?
Signup and view all the answers
What should happen if gas is detected during building entry?
What should happen if gas is detected during building entry?
Signup and view all the answers
Who maintains command of uncontrolled natural gas leaks?
Who maintains command of uncontrolled natural gas leaks?
Signup and view all the answers
What is the responsibility of the gas company upon arrival at a gas leak?
What is the responsibility of the gas company upon arrival at a gas leak?
Signup and view all the answers
What action should be taken regarding gas lines at a leak scene?
What action should be taken regarding gas lines at a leak scene?
Signup and view all the answers
How should zones be established around a gas leak?
How should zones be established around a gas leak?
Signup and view all the answers
What is the primary purpose of the natural gas leak operations guideline?
What is the primary purpose of the natural gas leak operations guideline?
Signup and view all the answers
Who is required to comply with the natural gas leak operations guideline?
Who is required to comply with the natural gas leak operations guideline?
Signup and view all the answers
What should be done immediately upon arrival at a suspected gas leak?
What should be done immediately upon arrival at a suspected gas leak?
Signup and view all the answers
What equipment must personnel wear while working in the hot zone of a gas leak?
What equipment must personnel wear while working in the hot zone of a gas leak?
Signup and view all the answers
Which area is to be classified as the hot zone in the context of gas leaks?
Which area is to be classified as the hot zone in the context of gas leaks?
Signup and view all the answers
Why is a charged hose line required in a known ignitable atmosphere?
Why is a charged hose line required in a known ignitable atmosphere?
Signup and view all the answers
What is a key responsibility of the Incident Commander at a gas leak scene?
What is a key responsibility of the Incident Commander at a gas leak scene?
Signup and view all the answers
What should be done with civilians in the area of a suspected gas leak?
What should be done with civilians in the area of a suspected gas leak?
Signup and view all the answers
What is the first action fire department personnel should take upon arrival at a natural gas leak scene?
What is the first action fire department personnel should take upon arrival at a natural gas leak scene?
Signup and view all the answers
What zones should be established based on initial air monitoring results?
What zones should be established based on initial air monitoring results?
Signup and view all the answers
Which of the following is prohibited for fire department personnel during a natural gas leak?
Which of the following is prohibited for fire department personnel during a natural gas leak?
Signup and view all the answers
Why should law enforcement be requested during a natural gas leak involving road closures?
Why should law enforcement be requested during a natural gas leak involving road closures?
Signup and view all the answers
What should be done if a natural gas leak is confirmed?
What should be done if a natural gas leak is confirmed?
Signup and view all the answers
What is a proper safety measure to take when monitoring a gas leak in dry conditions?
What is a proper safety measure to take when monitoring a gas leak in dry conditions?
Signup and view all the answers
What should be avoided when dealing with a cut gas line?
What should be avoided when dealing with a cut gas line?
Signup and view all the answers
What is the reviewed by personnel responsible for overseeing natural gas leak operations?
What is the reviewed by personnel responsible for overseeing natural gas leak operations?
Signup and view all the answers
Who is the direct contact office for questions regarding the Standard Operating Guideline?
Who is the direct contact office for questions regarding the Standard Operating Guideline?
Signup and view all the answers
What is the effective date of the Standard Operating Guideline SFD.085?
What is the effective date of the Standard Operating Guideline SFD.085?
Signup and view all the answers
What is indicated in the policy regarding the legal duty of members in connection to third-party claims?
What is indicated in the policy regarding the legal duty of members in connection to third-party claims?
Signup and view all the answers
Who is responsible for reviewing the SOG as per the information provided?
Who is responsible for reviewing the SOG as per the information provided?
Signup and view all the answers
What should you do if you notice an error or inconsistency in the policy?
What should you do if you notice an error or inconsistency in the policy?
Signup and view all the answers
What is the purpose of the 'List of Changes' section in the document?
What is the purpose of the 'List of Changes' section in the document?
Signup and view all the answers
What is indicated about violations of the policy within the document?
What is indicated about violations of the policy within the document?
Signup and view all the answers
Which revision number corresponds to the first edition of the SOG?
Which revision number corresponds to the first edition of the SOG?
Signup and view all the answers
Study Notes
Natural Gas Leak Operations
- Fire department personnel should immediately begin air monitoring upon arrival and wear personal protective equipment including SCBA in the hot zone until the area is deemed safe.
- All civilians should be evacuated from hazardous areas during a suspected or confirmed gas leak.
- A hot zone, warm zone, and cold zone should be established and maintained around any gas leak.
- The gas company will assume responsibility for controlling the leak upon arrival and the fire department will assist as needed.
- Only the minimally required personnel should enter the hot zone to size up the situation, determine the source of the leak, and isolate the leak if possible.
- The fire department should not leave the scene of a gas leak until they have determined the leak is controlled and the scene is safe.
- All entries into buildings with suspected gas leaks should involve the minimum number of personnel necessary to size up the situation and provide continuous air monitoring.
- Confirmed gas leaks inside a building should be isolated from the closest possible isolation point in a non-hazardous area if possible.
- Fire department personnel should not attempt to place any gas-powered equipment back into service including extinguished pilot lights.
- Upon arrival at a cut gas line, immediately begin air monitoring to determine the area affected and the potential hazards to life and property.
- Immediately address any potential life safety issues.
- Based on initial air monitoring, establish hot, warm, and cold zones.
- If a natural gas leak is confirmed, request the gas company respond to the scene if not already dispatched.
- SFD personnel will not clamp gas lines.
- Law enforcement should be requested for traffic control whenever a cut gas line involves possible road closures.
- When an underground gas line is leaking, the area should be continually monitored.
Other
- Any area with a gas accumulation of 10% LEL or greater should be considered as within the hot zone.
- The incident commander should consider deploying a charged hose line based on ignition hazards.
- The fire department will maintain command of all uncontrolled natural gas leaks inside its territory.
- Personnel working in a known ignitable atmosphere will be constantly monitored and covered with a charged hose line.
- Buildings with gas accumulation should be ventilated using natural ventilation and may be assisted with positive pressure ventilation operated in a monitored and safe location.
- In dry conditions with visibly cracked soil, cracks in the soil should be monitored, as the gas can travel large distances through fissures.
- Soil should not be placed on top of a cut gas line as this can facilitate the underground travel of gas.
- The appropriate contact office for questions or comments on this standard operating guideline (SOG) is the Fire Chief.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
This quiz covers essential procedures for fire department personnel responding to natural gas leaks. Participants will learn about air monitoring, zone establishment, evacuation protocols, and safety measures for personnel. Understanding these protocols is crucial for maintaining safety during hazardous situations involving gas leaks.