Which of the following is NOT a primary function of an air conditioning system?
Which of the following is NOT a primary function of an air conditioning system?
- Heating and humidifying air
- Air filtration
- Carbon Monoxide Detection (correct)
- Cooling and dehumidifying air
In the context of building design, what is the main purpose of a non-load bearing wall?
In the context of building design, what is the main purpose of a non-load bearing wall?
- To provide structural support for exterior walls
- To carry external loads to the foundation
- To divide interior spaces (correct)
- To support the weight of the floors above
Which of the following best describes the arrangement of an escalator?
Which of the following best describes the arrangement of an escalator?
- Neither parallel nor crisscross
- Crisscross only
- Either parallel or crisscross (correct)
- Parallel only
What is the primary factor determining the size and type of septic tank needed for a building?
What is the primary factor determining the size and type of septic tank needed for a building?
What is the maximum safe angle of inclination typically permitted for moving walkways and ramps designed for horizontal transportation?
What is the maximum safe angle of inclination typically permitted for moving walkways and ramps designed for horizontal transportation?
Which element listed is a component of an elevator system?
Which element listed is a component of an elevator system?
According to general safety practices, what should be the first action taken before using any tool or equipment in a workstation?
According to general safety practices, what should be the first action taken before using any tool or equipment in a workstation?
What is the purpose of the 'Seiso' step in the 5S methodology for standard operating procedure?
What is the purpose of the 'Seiso' step in the 5S methodology for standard operating procedure?
Which type of load is defined as the combined total weight of people within a building?
Which type of load is defined as the combined total weight of people within a building?
Which of the following best describes the function of a condenser coil in a window-type air conditioner?
Which of the following best describes the function of a condenser coil in a window-type air conditioner?
Flashcards
3 Pipe Lines
3 Pipe Lines
Water, sanitary, and storm drain lines.
Functions of AC systems
Functions of AC systems
Cooling & dehumidifying, heating & humidifying, and cleaning (filtration).
Types of AC systems
Types of AC systems
Cooling only split system, cooling only packaged system, heat pump, chilled water system, window air conditioners, packaged terminal heat pump.
Parts of window AC
Parts of window AC
Signup and view all the flashcards
Escalator
Escalator
Signup and view all the flashcards
Moving walks and ramps
Moving walks and ramps
Signup and view all the flashcards
Elevators
Elevators
Signup and view all the flashcards
Types of sprinkler systems
Types of sprinkler systems
Signup and view all the flashcards
Kinds of fitting
Kinds of fitting
Signup and view all the flashcards
Types of sewage disposal system
Types of sewage disposal system
Signup and view all the flashcards
Study Notes
- There are 3 types of pipe lines: water pipes, sanitary pipes, and storm drain pipes.
- Air conditioning systems cool and dehumidify air, heat and humidify air, and clean air through filtration.
- Types of AC systems include cooling-only split systems, cooling-only packaged systems, heat pumps, chilled water systems, window air conditioners, and packaged terminal heat pumps.
- A window-type AC unit has adjustable louvers, a control panel, a front grille, a filter, a thermostat sensor, an evaporator coil, a condenser coil (for liquefying), a compressor (reciprocating-piston type, centrifugal-rotary type), a fan, a partition, and a blower.
Escalators
- Escalators are moving stairways with classes of 32" and 48".
- Normal escalator speed is 90ft/min, with express speeds reaching 120ft/min and an angle of inclination of 30 degrees.
- Escalator components include a truss, track, controller, sprocket assemblies, chains, machines, handrail, and balustrade assembly.
- Escalators are arranged in parallel and crisscross configurations.
Moving Walks and Ramps
- Moving walks and ramps are for horizontal transportation, not exceeding 5 degrees inclination and are limited to 15 degrees.
Elevators (Lifts)
- Modern elevators consist of a cab (cage/car) mounted on a platform within an enclosed shaft or hoistway.
- Elevator elements include a hoistway, elevator car, cables, elevator machines, machine room, counterweights, guide rails, control equipment, and safety devices.
- Elevator types include gearless traction and geared traction systems.
- Elevator kinds are freight, dumbwaiter and plunger elevation.
- Fire sprinkler and alarm systems should be implemented as embodied in the National Building Code and Fire Code of the Philippines.
- Sprinkler systems come in fixed temperature and rate-of-rise types, providing excellent fire protection.
- Kinds of fitting: elbow 90 &45, tee, cross, couplings, reducers, nipples, cap, plug, bushing, unions
- Types of sewage disposal systems include cesspools, privies, septic tanks, and public sewer lines.
- Septic tank size and type vary based on the number of people served, contour, and soil type; pipes should be sloped.
- A catch basin is an example of a storm drain.
Important Practices in Technical Drawing
- Safety precautions must be observed, including no smoking, using clean tools, avoiding talking during work, turning off equipment before leaving, maintaining cleanliness, and using tools properly.
- Observe punctuality and respect, avoid quarrels, return borrowed items on time, and dispose of waste properly.
Architectural and Layout Details
- Architectural, structural, electrical, electronic, and mechanical layouts exist
- Sheets 1, 2, 3, 4, and 5 at scale 1:100
- Considerations include plotting in CAD, pen assignments, the first step in opening CAD, default layer settings, major-related learning, handling corrupted flash drives, actions during brownouts, pencil use in sketching, and symbols/abbreviations
OSHC Workplace Regulations
- Workplaces, equipment, and furnishings should be safe, clean, hygienic, and in good repair.
- Keep the place free from rodents, cockroaches, and other vermin.
- Provide hand washing, cleaning, and waste disposal facilities and establish infection control procedures.
- Keep the floor area free from waste, water, and grease, and keep cabinets dry, clean, and closed.
Standard Operating Procedure (5's)
- Five S's: Seiri (Sorting), Seiton (Set in order), Seiso (Sweeping), Shitsuke (Sustaining), Seiketsu (Standardizing).
Kinds of Loads
- Live load: load (combined total weight) of people
- Dead load: load of wood, steel, and furniture
- Wind load: the strength of wind
Kinds of Walls
- Walls are important components of a building, made of wood or concrete.
- Load-bearing walls support or carry loads in exterior walls.
- Non-load-bearing walls do not carry or support loads in partitions or interior walls.