Home Inspection and HVAC Systems Quiz
26 Questions
100 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What should an inspector do if they notice a strong smell of gas in a home?

Vacate the home and call appropriate people

What does the expansion device do?

Changes refrigerant from high temperature high pressure liquid to low temperature low pressure liquid

What occurs in the condensing coil?

Refrigerant changes from high temperature high pressure gas to high temperature high pressure liquid

What happens in the evaporator coil?

<p>Refrigerant changes from a low pressure low temperature liquid to a low temperature low pressure gas</p> Signup and view all the answers

What function does the compressor serve?

<p>Changes refrigerant from a low pressure low temperature gas to a high temperature high pressure gas</p> Signup and view all the answers

What are automatic safety controls designed for?

<p>To protect systems and components from unsafe conditions</p> Signup and view all the answers

What defines central air conditioning?

<p>A system that uses ducts or pipes to distribute cooled air or chilled water to multiple rooms</p> Signup and view all the answers

What is a component in the context of home inspection?

<p>A readily accessible and observable aspect of a system</p> Signup and view all the answers

What is cosmetic damage?

<p>Superficial blemishes or defects that do not interfere with functionality</p> Signup and view all the answers

What is a cross connection?

<p>Any physical connection between potable water and a source of contamination</p> Signup and view all the answers

What defines a dangerous or adverse situation?

<p>Situations that pose a threat of injury to the inspector</p> Signup and view all the answers

What does it mean to describe in the context of inspection?

<p>Report in writing a system or component by its type or characteristics</p> Signup and view all the answers

What does dismantling a component involve?

<p>Taking apart or removing any component that is fastened in place</p> Signup and view all the answers

What does it mean to enter an area during an inspection?

<p>To go into an area to inspect all visible components</p> Signup and view all the answers

What is functional drainage?

<p>A drain that empties in a reasonable time without overflowing</p> Signup and view all the answers

What is functional flow?

<p>A reasonable flow at the highest fixture when another is operated simultaneously</p> Signup and view all the answers

What constitutes a habitable space?

<p>A space for living, sleeping, eating, or cooking not used for storage</p> Signup and view all the answers

What does it mean to inspect?

<p>The act of making a visual inspection</p> Signup and view all the answers

What does installed mean?

<p>Connected in such a way that requires tools for removal</p> Signup and view all the answers

What are normal operating controls?

<p>Homeowner-operated devices like a thermostat or wall switch</p> Signup and view all the answers

What does on-site water supply quality refer to?

<p>Water quality based on bacterial, chemical, mineral content</p> Signup and view all the answers

What does it mean to operate a system?

<p>To cause systems or equipment to function</p> Signup and view all the answers

What does readily accessible mean?

<p>A panel that can be removed or opened by one person</p> Signup and view all the answers

What does readily visible mean?

<p>Can be seen using natural or artificial light without tools</p> Signup and view all the answers

What is a representative number in inspections?

<p>One component per room for identical items</p> Signup and view all the answers

What does the roof drainage system include?

<p>Gutters, downspouts, leaders, and splash blocks</p> Signup and view all the answers

Study Notes

Home Inspection Safety and Procedures

  • In case of detecting a strong gas smell, vacate the premises and notify the appropriate authorities immediately.
  • Dangerous or adverse situations require special safety equipment and may pose injury risks to inspectors.

Refrigeration and Air Conditioning Components

  • The expansion device converts high temperature, high pressure liquid refrigerant into low temperature, low pressure liquid.
  • The condensing coil transforms high temperature, high pressure gas into high temperature, high pressure liquid.
  • The evaporator coil changes low pressure, low temperature liquid refrigerant into low temperature, low pressure gas.
  • The compressor converts low pressure, low temperature gas into high temperature, high pressure gas.

Safety Measures and System Components

  • Automatic safety controls protect systems from extreme pressures, temperatures, and various hazardous conditions.
  • Central air conditioning systems distribute cooled air using ducts or chilled water to multiple rooms, excluding plug-in units.
  • A component in home inspections refers to observable aspects like walls or floors, rather than individual parts like nails.
  • Cosmetic damage includes visible defects that do not affect the functionality of the system or component.
  • A cross-connection is any arrangement linking potable water to potential contamination sources.
  • Functional drainage is characterized by timely empting without overflow during simultaneous use of other fixtures.
  • Functional flow ensures reasonable water flow at the highest fixture during concurrent operations of other fixtures.

Space and Inspection Regulations

  • Habitable space refers to areas designated for living, sleeping, eating, or cooking, excluding bathrooms, closets, and storage areas.
  • The term "inspect" refers to making a visual examination of all visible components.
  • Installed items require tools for removal, indicating a fixed connection.
  • Normal operating controls are devices operated by homeowners, such as thermostats and switches.

Accessibility and Visibility in Inspections

  • Readily accessible panels are designed for easy homeowner inspection with removable fasteners, reachable from a standard ladder without obstruction.
  • Readily visible components can be seen with basic lighting, negating the need for specialized tools beyond a flashlight.

Sampling and Representation in Inspections

  • A representative number method means inspecting one component per room for identical items, and one per side for external components.
  • The roof drainage system includes essential components like gutters and downspouts which ensure effective water management.

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

Description

Test your knowledge on home inspection safety procedures and the components of refrigeration and air conditioning systems. Understand the essential safety measures and the roles of various system components in maintaining a safe and efficient environment. This quiz is perfect for anyone interested in HVAC technology and home safety standards.

More Like This

Interior Design: HVAC and Building Systems
11 questions
HVAC Efficiency Ratings
12 questions
Safety Requirements for HVAC Systems
40 questions
HVAC Systems and Thermodynamics Quiz
21 questions
Use Quizgecko on...
Browser