What is the maximum SAR that can be used for MRI scans of coronary artery stents?

  • 1.5 W/kg
  • 2 W/kg (correct)
  • 3 W/kg
  • 4 W/kg
  • What is the maximum magnetic field strength that can be used to scan commercially available coronary artery stents?

  • 1.0 Tesla
  • 1.5 Tesla
  • 2.0 Tesla
  • 3.0 Tesla (correct)
  • What is the minimum wall thickness of the pipe material?

  • 0.5 mm
  • 2 mm
  • 3 mm (correct)
  • 4 mm
  • What is the minimum distance from the finished wall to the centerline of the toilet on both sides when a regular toilet is used?

    <p>44 inches (1.12 meters</p> Signup and view all the answers

    What must MRI suites with a static magnetic field of 5 gauss (0.5 millitesla) meet in order to be compliant?

    <p>The four-zone screening and access control protocols identified in the current edition of the American College of Radiology’s “ACR Manual on MR Safety.”</p> Signup and view all the answers

    What should be avoided when removing conventional doors and frames to facilitate delivery/removal of MRI scanners?

    <p>Demolition of partitions</p> Signup and view all the answers

    What must be done to areas in which the magnetic field strength is equal to or greater than 5 gauss (0.5 millitesla)?

    <p>Physically restrict by the use of key locks or pass-key locking systems</p> Signup and view all the answers

    What should the operator's console be positioned so that they can see?

    <p>The entrance to the MRI scanner room</p> Signup and view all the answers

    What is the minimum distance between the outlet and any restriction such as the roof or wall?

    <p>100 cm</p> Signup and view all the answers

    What is required to restrict the magnetic field plot?

    <p>Magnetic shielding</p> Signup and view all the answers

    Which of the following is a requirement for MRI scanning of coronary artery stents?

    <p>Obtaining prior approval from a Radiologist</p> Signup and view all the answers

    What is the minimum clear floor area that should extend from the front of the toilet?

    <p>46 inches (1.17 meters</p> Signup and view all the answers

    What is the minimum SAR required for MRI examination of coronary artery stents?

    <p>2.0 W/kg</p> Signup and view all the answers

    What should be located outside the MRI scanner room?

    <p>The entry vestibule</p> Signup and view all the answers

    What must be provided in the MRI suite, in addition to the clinical and support areas?

    <p>All of the above</p> Signup and view all the answers

    What is the required magnetic field strength of an MRI scanner device?

    <p>5 gauss</p> Signup and view all the answers

    What is the purpose of IEC Standard 60601-2-33?

    <p>To prevent unscreened individuals from entering the 5-gauss (0.5-millitesla) volume</p> Signup and view all the answers

    What should be considered during design?

    <p>Delivery and removal of an MRI scanner</p> Signup and view all the answers

    What is the concentrated load capacity of the grab bars in toilet rooms intended for use by individuals of size?

    <p>800 pounds (362.87 kilograms</p> Signup and view all the answers

    What should be taken into consideration when locating the MRI unit?

    <p>The quantity and distance of structural steel</p> Signup and view all the answers

    What type of material should be used to cover the opening of the quench vent pipe?

    <p>Wire mesh</p> Signup and view all the answers

    What is the minimum time required for each MRI sequence when examining coronary artery stents?

    <p>15 minutes</p> Signup and view all the answers

    When can coronary artery stents be scanned using MRI?

    <p>Immediately after placement</p> Signup and view all the answers

    What is the minimum clearance from air intakes, operable windows, or doors as defined by the MRI system manufacturer for the cryogen venting point?

    <p>5 gauss (0.5 millitesla</p> Signup and view all the answers

    What type of prior approval is required when deviating from the parameters specified for MRI examination of coronary artery stents?

    <p>Radiologist approval</p> Signup and view all the answers

    What is the minimum distance the vent pipe should be from walking surfaces?

    <p>5 m</p> Signup and view all the answers

    What is the minimum clear widths for door openings to toilet rooms designated for individuals of size?

    <p>36 inches (91.44 centimeters</p> Signup and view all the answers

    What must be provided in the MRI suite, in addition to the cryogen venting point?

    <p>A system component room that meets the requirements in Section 2.1-3.5.2.5</p> Signup and view all the answers

    What type of signage should be included in the electrical details of the MRI room?

    <p>A sign indicating the magnet is always on</p> Signup and view all the answers

    What should be avoided near an MRI scanner?

    <p>Structural steel</p> Signup and view all the answers

    What is the minimum MRI system that can be used to scan coronary artery stents?

    <p>1.5 Tesla</p> Signup and view all the answers

    What is the purpose of cryogen vent pipes?

    <p>To be clearly marked and shielded from staff and maintenance areas</p> Signup and view all the answers

    What type of seating should be provided in waiting areas in outpatient facilities for individuals of size?

    <p>Expanded-capacity seating</p> Signup and view all the answers

    What should be considered when locating an MRI unit?

    <p>The location, quantity, and distance of structural steel</p> Signup and view all the answers

    What is the minimum area of the end of the opening?

    <p>2.5 times the cross section area of the quench line</p> Signup and view all the answers

    What is required for the use of anesthesia support in the MRI scanner room?

    <p>All of the above</p> Signup and view all the answers

    Which of the following is not a requirement for MRI scanning of coronary artery stents?

    <p>Using an MRI system with 4 Tesla</p> Signup and view all the answers

    What should the wall, floor, and ceiling assemblies accommodate?

    <p>The installation of RF-shielded assemblies</p> Signup and view all the answers

    Does the information provided in the text apply to other types of stents?

    <p>No</p> Signup and view all the answers

    What type of access control must be used for any area in which the magnetic field strength is equal to or greater than 5 gauss (0.5 millitesla)?

    <p>Pass-key locking systems</p> Signup and view all the answers

    Study Notes

    • All current, commercially available coronary artery stents can be scanned using MRI at either 1.5 or 3 Tesla.
    • Immediately after placement, patients with coronary artery stents can undergo MRI.
    • The MRI examination must be performed using the following parameters: 1.5 or 3 Tesla, only, with a SAR of 2 W/kg, and using the Normal Operating Mode of operation for the MR system.
    • Any deviation from the above MRI conditions requires prior approval by the Radiologist.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Test your knowledge on MRI scanning for patients with coronary artery stents, including the required parameters and conditions for the examination.

    More Like This

    MRI Exam #1 Flashcards
    38 questions

    MRI Exam #1 Flashcards

    AudibleFresno2256 avatar
    AudibleFresno2256
    MRI All in One Flashcards
    25 questions

    MRI All in One Flashcards

    LionheartedBrazilNutTree avatar
    LionheartedBrazilNutTree
    Use Quizgecko on...
    Browser
    Browser