What is the required minimum clearance between the roof and any overhead obstruction if the roof slope is less than 30 degrees?
What is the required minimum clearance between the roof and any overhead obstruction if the roof slope is less than 30 degrees?
- 7 feet (correct)
- 10 feet
- 6 feet
- 8 feet
How often must the fire alarm system be tested according to the regulations?
How often must the fire alarm system be tested according to the regulations?
- Monthly (correct)
- Biannually
- Weekly
- Annually
What is the minimum height requirement for storage below unsprinklered ceilings?
What is the minimum height requirement for storage below unsprinklered ceilings?
- 5 feet
- 4 feet
- 3 feet (correct)
- 2 feet
What is the purpose of the sign required to be posted near the control panel?
What is the purpose of the sign required to be posted near the control panel?
Which of the following is NOT permitted on the roof?
Which of the following is NOT permitted on the roof?
Where should the Fire Department's telephone number be posted?
Where should the Fire Department's telephone number be posted?
What is the required minimum width for gates to ensure Fire Department access?
What is the required minimum width for gates to ensure Fire Department access?
What is the minimum distance required between materials stored below sprinklered ceilings?
What is the minimum distance required between materials stored below sprinklered ceilings?
How often must a fire drill be conducted in schools according to the regulations?
How often must a fire drill be conducted in schools according to the regulations?
What is NOT required to be displayed on the service tag?
What is NOT required to be displayed on the service tag?
What should be done if a drill observed requires correction?
What should be done if a drill observed requires correction?
Which piece of information is NOT required on the service tag?
Which piece of information is NOT required on the service tag?
What must be clearly functional in the fire alarm system during a drill?
What must be clearly functional in the fire alarm system during a drill?
What should be displayed at the top of the service tag?
What should be displayed at the top of the service tag?
Which materials are prohibited for use due to their level of vapor toxicity?
Which materials are prohibited for use due to their level of vapor toxicity?
If a fire drill needs correction, what is an acceptable course of action?
If a fire drill needs correction, what is an acceptable course of action?
Why should a drill not be requested during State Tests?
Why should a drill not be requested during State Tests?
What is the primary purpose of sealing a fire extinguisher?
What is the primary purpose of sealing a fire extinguisher?
How often must every fire extinguisher be inspected and serviced?
How often must every fire extinguisher be inspected and serviced?
What information must be included on a service tag attached to a fire extinguisher?
What information must be included on a service tag attached to a fire extinguisher?
What type of seal must be provided on fire extinguishers with a seated-valve type gas-cylinder assembly?
What type of seal must be provided on fire extinguishers with a seated-valve type gas-cylinder assembly?
What must be done immediately after a fire extinguisher is used?
What must be done immediately after a fire extinguisher is used?
What should the sealing method of a fire extinguisher ensure?
What should the sealing method of a fire extinguisher ensure?
Which of the following is not a requirement for fire extinguisher servicing?
Which of the following is not a requirement for fire extinguisher servicing?
Study Notes
Control Panel Maintenance
- A sign must be placed at the control panel with comprehensive maintenance and operational instructions for easy reference.
Fire Department Communication
- Fire Department phone number needs to be visibly posted in the main office or switchboard for immediate access.
Fire Alarm Testing Requirements
- Fire alarm systems require monthly testing to meet Chief’s satisfaction.
- Manual stations must be tested on a rotating basis, ensuring one station is tested each month.
Fire Department Access Specifications
- Gates should be at least 20 feet wide and easily operable for Fire Department access.
Roof Regulations
- No materials that may impede egress or firefighting activities can be stored on rooftops.
- Overhead obstructions are prohibited on roofs with slopes less than 30 degrees or those with a penthouse unless a clearance of 7 feet is maintained.
- Exception for guy wires supporting antenna masts if they do not extend more than one-sixth the height of the mast laterally.
Storage Clearances Below Ceilings
- Minimum clearance of 3 feet below unsprinklered ceilings and 18 inches below sprinklered ceilings is mandated for storage.
Flameproofing and Decorations
- Decorations must comply with flameproofing regulations, with tags indicating last service date, license numbers, and service details.
Fire Drill Regulations
- Schools are required to conduct fire drills monthly, with private schools often lacking adherence.
- Drills must be performed upon Department request, except during state tests.
- All bells must sound clearly during drills, ensuring proper functionality.
Sealing Requirements for Fire Extinguishers
- Fire extinguishers should be sealed with a wire and seal marked with the servicing technician's registration number.
- Sealing must be performed to prevent discharge without breaking the seal.
Servicing and Inspection of Fire Extinguishers
- Extinguishers must be inspected and serviced annually or immediately post-use.
- A service tag detailing service information must be attached and updated with each service.
Hydrostatic Testing Requirements
- Hydrostatic test tags must include the test date and the license registration number of the testing agency.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
This quiz covers essential fire safety regulations, including control panel maintenance, fire department communication, and fire alarm testing requirements. Learn about the specifications for fire department access and roof regulations to ensure safety and compliance.