Fire Safety Regulations Overview
24 Questions
0 Views

Fire Safety Regulations Overview

Created by
@FancyDalmatianJasper

Questions and Answers

What is the required minimum clearance between the roof and any overhead obstruction if the roof slope is less than 30 degrees?

  • 7 feet (correct)
  • 10 feet
  • 6 feet
  • 8 feet
  • How often must the fire alarm system be tested according to the regulations?

  • Monthly (correct)
  • Biannually
  • Weekly
  • Annually
  • What is the minimum height requirement for storage below unsprinklered ceilings?

  • 5 feet
  • 4 feet
  • 3 feet (correct)
  • 2 feet
  • What is the purpose of the sign required to be posted near the control panel?

    <p>To provide system maintenance and operating instructions</p> Signup and view all the answers

    Which of the following is NOT permitted on the roof?

    <p>Guy wires for antenna masts</p> Signup and view all the answers

    Where should the Fire Department's telephone number be posted?

    <p>At the main switchboard and/or office</p> Signup and view all the answers

    What is the required minimum width for gates to ensure Fire Department access?

    <p>20 feet</p> Signup and view all the answers

    What is the minimum distance required between materials stored below sprinklered ceilings?

    <p>18 inches</p> Signup and view all the answers

    How often must a fire drill be conducted in schools according to the regulations?

    <p>At least once each school month</p> Signup and view all the answers

    What is NOT required to be displayed on the service tag?

    <p>Color of the service tag</p> Signup and view all the answers

    What should be done if a drill observed requires correction?

    <p>Advise the principal that another drill will be required on a subsequent visit</p> Signup and view all the answers

    Which piece of information is NOT required on the service tag?

    <p>Name of the fire marshal conducting the inspection</p> Signup and view all the answers

    What must be clearly functional in the fire alarm system during a drill?

    <p>All bells on the system</p> Signup and view all the answers

    What should be displayed at the top of the service tag?

    <p>DO NOT REMOVE BY ORDER OF THE STATE FIRE MARSHAL</p> Signup and view all the answers

    Which materials are prohibited for use due to their level of vapor toxicity?

    <p>Carbon tetrachloride and chlorobromomethane</p> Signup and view all the answers

    If a fire drill needs correction, what is an acceptable course of action?

    <p>Request another drill the same day if extremely poor</p> Signup and view all the answers

    Why should a drill not be requested during State Tests?

    <p>It disrupts the testing environment</p> Signup and view all the answers

    What is the primary purpose of sealing a fire extinguisher?

    <p>To prevent unauthorized access to the extinguisher</p> Signup and view all the answers

    How often must every fire extinguisher be inspected and serviced?

    <p>Yearly or after each use</p> Signup and view all the answers

    What information must be included on a service tag attached to a fire extinguisher?

    <p>Date of the test and license registration number</p> Signup and view all the answers

    What type of seal must be provided on fire extinguishers with a seated-valve type gas-cylinder assembly?

    <p>Metal wire and a lead seal</p> Signup and view all the answers

    What must be done immediately after a fire extinguisher is used?

    <p>Inspect and service the unit</p> Signup and view all the answers

    What should the sealing method of a fire extinguisher ensure?

    <p>That the extinguisher cannot be discharged without breaking the seal</p> Signup and view all the answers

    Which of the following is not a requirement for fire extinguisher servicing?

    <p>Have a visual inspection every two years</p> Signup and view all the answers

    Study Notes

    Control Panel Maintenance

    • A sign must be placed at the control panel with comprehensive maintenance and operational instructions for easy reference.

    Fire Department Communication

    • Fire Department phone number needs to be visibly posted in the main office or switchboard for immediate access.

    Fire Alarm Testing Requirements

    • Fire alarm systems require monthly testing to meet Chief’s satisfaction.
    • Manual stations must be tested on a rotating basis, ensuring one station is tested each month.

    Fire Department Access Specifications

    • Gates should be at least 20 feet wide and easily operable for Fire Department access.

    Roof Regulations

    • No materials that may impede egress or firefighting activities can be stored on rooftops.
    • Overhead obstructions are prohibited on roofs with slopes less than 30 degrees or those with a penthouse unless a clearance of 7 feet is maintained.
    • Exception for guy wires supporting antenna masts if they do not extend more than one-sixth the height of the mast laterally.

    Storage Clearances Below Ceilings

    • Minimum clearance of 3 feet below unsprinklered ceilings and 18 inches below sprinklered ceilings is mandated for storage.

    Flameproofing and Decorations

    • Decorations must comply with flameproofing regulations, with tags indicating last service date, license numbers, and service details.

    Fire Drill Regulations

    • Schools are required to conduct fire drills monthly, with private schools often lacking adherence.
    • Drills must be performed upon Department request, except during state tests.
    • All bells must sound clearly during drills, ensuring proper functionality.

    Sealing Requirements for Fire Extinguishers

    • Fire extinguishers should be sealed with a wire and seal marked with the servicing technician's registration number.
    • Sealing must be performed to prevent discharge without breaking the seal.

    Servicing and Inspection of Fire Extinguishers

    • Extinguishers must be inspected and serviced annually or immediately post-use.
    • A service tag detailing service information must be attached and updated with each service.

    Hydrostatic Testing Requirements

    • Hydrostatic test tags must include the test date and the license registration number of the testing agency.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz covers essential fire safety regulations, including control panel maintenance, fire department communication, and fire alarm testing requirements. Learn about the specifications for fire department access and roof regulations to ensure safety and compliance.