What are two key components that must be included in the incident report after a sprinkler system activation?
What are two key components that must be included in the incident report after a sprinkler system activation?
What is the initial pressure to which supply lines should be charged when supplementing the water supply?
What is the initial pressure to which supply lines should be charged when supplementing the water supply?
Which control valves must be verified to be open in a building with hose cabinets and standpipes?
Which control valves must be verified to be open in a building with hose cabinets and standpipes?
What should a driver operator do if the fire pump does not start automatically?
What should a driver operator do if the fire pump does not start automatically?
Signup and view all the answers
What should be done if a fire pump that is present has not started?
What should be done if a fire pump that is present has not started?
Signup and view all the answers
Which of the following statements is true regarding closed valves during an incident?
Which of the following statements is true regarding closed valves during an incident?
Signup and view all the answers
What must be completed in addition to the required incident report after a sprinkler system activation?
What must be completed in addition to the required incident report after a sprinkler system activation?
Signup and view all the answers
When can the sprinkler system be shut off?
When can the sprinkler system be shut off?
Signup and view all the answers
Which hydraulic condition should be monitored when adjusting the pressure at the Fire Department Connection?
Which hydraulic condition should be monitored when adjusting the pressure at the Fire Department Connection?
Signup and view all the answers
What should be done to stop water flow from fused sprinkler heads?
What should be done to stop water flow from fused sprinkler heads?
Signup and view all the answers
What should a firefighter do if they find a valve marked 'Closed for Repair'?
What should a firefighter do if they find a valve marked 'Closed for Repair'?
Signup and view all the answers
What action should be taken before closing control valves for sprinkler systems?
What action should be taken before closing control valves for sprinkler systems?
Signup and view all the answers
Who is responsible for making repairs to the sprinkler system post-incident?
Who is responsible for making repairs to the sprinkler system post-incident?
Signup and view all the answers
What is the primary reason for replacing activated sprinkler heads and recharging the system?
What is the primary reason for replacing activated sprinkler heads and recharging the system?
Signup and view all the answers
After a fire incident, who should the IC report the status of the sprinkler system to?
After a fire incident, who should the IC report the status of the sprinkler system to?
Signup and view all the answers
What should a firefighter do if repairs to the sprinkler system are needed after a fire?
What should a firefighter do if repairs to the sprinkler system are needed after a fire?
Signup and view all the answers
What is the purpose of the standard operating guideline SOG 100-04?
What is the purpose of the standard operating guideline SOG 100-04?
Signup and view all the answers
Which action must the second arriving engine take in a sprinklered building?
Which action must the second arriving engine take in a sprinklered building?
Signup and view all the answers
What pressure should the supply lines be maintained at when supporting a sprinkler system?
What pressure should the supply lines be maintained at when supporting a sprinkler system?
Signup and view all the answers
Why should static water sources not be used to support fire protection systems connected to a potable water supply?
Why should static water sources not be used to support fire protection systems connected to a potable water supply?
Signup and view all the answers
Which valves must be verified as open during fire operations in sprinklered buildings?
Which valves must be verified as open during fire operations in sprinklered buildings?
Signup and view all the answers
What should be done if a sprinkler control valve is found closed and marked 'Closed for Repair'?
What should be done if a sprinkler control valve is found closed and marked 'Closed for Repair'?
Signup and view all the answers
What is the role of the second arriving engine in relation to water supply management?
What is the role of the second arriving engine in relation to water supply management?
Signup and view all the answers
During post-incident follow-up, what should be evaluated regarding control valves?
During post-incident follow-up, what should be evaluated regarding control valves?
Signup and view all the answers
Study Notes
Incident Reporting
- Complete an incident report following Incident Reporting guidelines (PPM FR-M-201) whenever a sprinkler system is activated.
- Include a Life Safety Systems Activation (100-04 Attachment A) with the report.
- Document any issues faced while operating the fire protection system.
- Record actions taken by Fire Rescue personnel during the incident.
- Note any closed valves (e.g., sprinkler control valves, OS&Y).
Building Operations with Hose Cabinets and Standpipes
- Second arriving engine must connect to Fire Department Connection (FDC) using at least two 3” supply lines and connect to a hydrant with LDH.
- Initial supply line pressure set to 100 psi, adjusted as per hose layout.
- Maintain FDC pressure below 200 psi.
- Verify all sprinkler control valves (PIV, WIV, OS&Y) are open; open them unless directed otherwise by the Incident Commander (IC).
- If valves are marked "Closed for Repair," notify the IC and wait for further instructions.
Fire Pump Operations
- Ensure the fire pump is operational; start it using manual controls if it isn’t running.
- If the pump fails to start, inform the IC immediately.
Control of Sprinkler System
- Do not shut off the sprinkler system until the fire is extinguished or at the IC's discretion.
- Stop water flow from fused sprinkler heads quickly to limit water damage; use zone control valve if multiple heads are activated.
- Control valves should only be closed upon IC’s order; have a firefighter ready to reopen if needed.
- Activated sprinkler heads should be replaced and the system recharged, but the building owner must contact a licensed contractor for required repairs.
Post-Incident Follow Up
- IC must update the B.O.S.S. about the status of the sprinkler system after the incident.
- Attempt to inform the building representative of necessary repairs; responsibility for repairs lies with the building owner.
General Guidelines
- These procedures apply to emergency operations personnel responding to fires in buildings with fire protection systems (sprinklers and/or hose cabinets).
- Ensure water supply for firefighting does not compromise the building’s fire protection system integrity.
- Static water sources (lakes, canals) should not support fire protection systems connected to potable water supplies.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
This quiz covers the essential procedures for reporting incidents related to the activation of sprinkler systems. Participants will learn about the specific forms and information required, including the Incident Report and details on any challenges faced during the response. Enhance your understanding of life safety systems protocols.