EOG 300 Fire Department property conservation and fire streams
34 Questions
1 Views

EOG 300 Fire Department property conservation and fire streams

Created by
@HeavenlyAntimony5079

Questions and Answers

What is the flow rate delivered by the 1 3/4" Preconnect with the SM-20F Fog Nozzle at the recommended pump pressure?

  • 150 gpm
  • 100 gpm (correct)
  • 125 gpm
  • 75 gpm
  • What is the effective coverage area of a single 1 3/4" Preconnect with the SM-20F Fog Nozzle for single-story involvement?

  • 1000 - 1200 square feet
  • 600 - 1000 square feet (correct)
  • 400 - 600 square feet
  • 600 - 800 square feet
  • At what pump pressure does the SM-20F Fog Nozzle operate to deliver its rated flow?

  • 110 psi (correct)
  • 120 psi
  • 100 psi
  • 90 psi
  • Which of the following is NOT mentioned as a feature of TFD Apparatus hose and nozzles?

    <p>Specific nozzle types are limited</p> Signup and view all the answers

    How many gallons per minute (gpm) does the SM-20F Fog Nozzle deliver?

    <p>100 gpm</p> Signup and view all the answers

    What is the primary hose size that SM-30F fog nozzles are designed for?

    <p>3'' handlines</p> Signup and view all the answers

    If SM-30F fog nozzles are removed from the playpipe, which line size can they still be effectively used on?

    <p>1 3/4'' or 2'' lines</p> Signup and view all the answers

    What flow increase should an officer expect when using SM-30F fog nozzles on a 1 3/4'' line?

    <p>25%</p> Signup and view all the answers

    What happens when SM-30F fog nozzles are installed on 1 3/4'' lines compared to their standard use?

    <p>They increase flow rate.</p> Signup and view all the answers

    What type of equipment are SM-30F fog nozzles classified as?

    <p>Fog nozzles</p> Signup and view all the answers

    Which support activity is specifically mentioned to assist in fire control and rescue operations?

    <p>Utility Control</p> Signup and view all the answers

    Which method is recommended for ventilation prior to entry into a structure?

    <p>Taking out a window in the fire area</p> Signup and view all the answers

    What is the primary responsibility of the Incident Commander (IC) regarding utility control?

    <p>To call for utility companies to control their respective utilities</p> Signup and view all the answers

    Why is fireground lighting important during early stages of fire control?

    <p>To increase fireground safety</p> Signup and view all the answers

    What should happen if the assigned ventilation company cannot complete a task timely?

    <p>Another company should be assigned the function</p> Signup and view all the answers

    In the context of traditional responsibilities, which apparatus typically handles support functions like ventilation and utility control?

    <p>Ladder Companies</p> Signup and view all the answers

    What occurs if someone other than the ventilation company controls utilities during an operation?

    <p>The IC must be notified to prevent duplication of effort</p> Signup and view all the answers

    What should be arranged for early in the fire incident regarding scene lighting?

    <p>Whole-scene lighting should be arranged</p> Signup and view all the answers

    What is one of the main priorities when implementing property conservation activities?

    <p>Reduce property loss with the same urgency as life safety.</p> Signup and view all the answers

    Which action should be taken when the fire is determined to be under control?

    <p>Evaluate personnel assigned to fire control before reassigning them.</p> Signup and view all the answers

    When should early salvage operations be initiated?

    <p>When there is a confirmed need for simultaneous fire attack and loss control.</p> Signup and view all the answers

    What is a critical consideration when a fire investigator has arrived at the scene?

    <p>Non-essential companies should be withdrawn once fire control is achieved.</p> Signup and view all the answers

    How should water application be managed after a fire is knocked down?

    <p>Water streams must be shut down and only used judiciously.</p> Signup and view all the answers

    What role does the Customer Service Group play during an emergency incident?

    <p>To supervise and meet the immediate needs of occupants/owners.</p> Signup and view all the answers

    Why is evaluation of personnel condition crucial before reassigning them?

    <p>To avoid potential fatigue-related inefficiencies and injuries.</p> Signup and view all the answers

    What should be limited during the cause/determination phase of an incident?

    <p>Overhaul operations until the investigation is complete.</p> Signup and view all the answers

    What should be considered when selecting a fire stream?

    <p>Fire size and location, fireground strategy, and water supply</p> Signup and view all the answers

    Which statement about offensive attacks is true?

    <p>Quick fire control is essential to avoid becoming defensive.</p> Signup and view all the answers

    What is the recommended action when switching from an interior to an exterior attack?

    <p>Set aside the interior lines and replace them with larger handlines and master streams.</p> Signup and view all the answers

    Why should firefighters avoid using fog streams in confined areas?

    <p>Large volumes of steam can be generated, compromising safety.</p> Signup and view all the answers

    What is a 'blitz attack' as defined in the guidelines?

    <p>An initial attack using a master stream for a quick knockdown followed by handlines.</p> Signup and view all the answers

    What should be avoided when conducting interior operations?

    <p>Combining interior and exterior fire stream operations.</p> Signup and view all the answers

    What characteristic of solid bore nozzles is highlighted in the guidelines?

    <p>They provide excellent penetration and distance during application.</p> Signup and view all the answers

    Which of the following should be prioritized before entry into a structure during firefighting operations?

    <p>Ventilation to reduce hazards from steam.</p> Signup and view all the answers

    Study Notes

    Property Conservation

    • TFD prioritizes property conservation alongside life safety and fire control efforts.
    • Resources are committed to minimize property loss; actions must be proactive and aggressive.
    • Fire streams should be ceased when the fire is under control to prevent water damage.
    • Recognizing when fire progress stops is crucial for reducing losses.
    • Personnel assigned to rescue or fire control should be evaluated for fatigue before reassigning to loss control duties.
    • Early salvage operations play a critical role in minimizing loss during incidents.
    • Simultaneous fire attack and loss control may require additional resources for effective execution.
    • Loss control activities should be integrated into the cause and determination phase of the incident.
    • Non-essential companies should withdraw once fire control is achieved to allow investigations to proceed.
    • Scene control is necessary to preserve evidence for investigations.
    • Customer Service Group should engage with occupants or owners to address immediate needs post-incident.

    Support Activities

    • Support activities enhance fire control and rescue operations, including:
      • Ventilation
      • Utility control
      • Scene lighting

    Ventilation

    • Structures should be vented prior to firefighter entry when feasible.
    • For example, venting a window before interior attack in residential fires can improve safety and effectiveness.

    Utility Control

    • The Incident Commander (IC) is responsible for notifying utility companies and controlling utilities where feasible by TFD.

    Scene Lighting

    • Adequate fireground lighting enhances safety and should be established early during incidents.

    Assignment of Support Functions

    • Traditionally, ventilation, utility control, and lighting are managed by ladder companies, but roles may shift due to operational conditions.
    • Companies responsible for ventilation must ensure lighting and utility control are also executed or alert the IC if unable to complete tasks.

    Fire Streams/Water Supply

    • Fire stream selection is influenced by fire size, location, strategy, and available water supply; multiple types of streams may be necessary.
    • Quick fire control is essential for offensive attacks; failure to do so warrants a defensive strategy.
    • Master streams can serve both offensive and defensive roles; effective application includes short bursts to gain control followed by handline advances.
    • Do not combine exterior and interior fire stream operations.
    • Use solid bore nozzles for effective penetration and distance when deploying master streams; be cautious with fog streams in confined spaces to avoid steam hazards.

    Specific Equipment Guidelines

    • 1 ¾” Preconnects equipped with SM-20F Fog Nozzle deliver ~100 gpm at 110 psi, sufficient for 600 to 1000 square feet of coverage.
    • SM-30F fog nozzles primarily utilized on 3" handlines can also be adapted for 1 ¾” lines, offering a potential flow increase of 25% when used in the latter context.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz covers the emergency operating guidelines for fire departments, focusing on the strategic and tactical considerations for property conservation. Participants will learn how to balance property conservation efforts with life safety and fire control responsibilities. Understanding these guidelines is essential for effective incident management.

    More Quizzes Like This

    Property and Casualty Insurance Test 1
    26 questions
    202.12 LOSS CONTROL
    10 questions

    202.12 LOSS CONTROL

    WellRunCanyon3722 avatar
    WellRunCanyon3722
    Use Quizgecko on...
    Browser
    Browser