According to SOG 100-03, what is the standard response code for units dispatched to an automatic fire alarm?
According to SOG 100-03, what is the standard response code for units dispatched to an automatic fire alarm?
- Code 1, unless updated information warrants a different response. (correct)
- Code 3, with discretion based on communications center updates.
- Code 4, prioritizing life safety above all else.
- Code 2, unless otherwise directed by dispatch.
When is forcible entry justified based on SOG 100-03 during a fire alarm response?
When is forcible entry justified based on SOG 100-03 during a fire alarm response?
- Only after the fire alarm system has been reset to prevent further alerts.
- When the building is equipped with a Knox Box that is known to be inoperable.
- As a standard procedure to ensure rapid access and assessment.
- When a key holder is unavailable, and there are indications of a potential fire. (correct)
What immediate actions should personnel take when responding to a water flow alarm with no visible fire from Side Alpha?
What immediate actions should personnel take when responding to a water flow alarm with no visible fire from Side Alpha?
- Immediately force entry to assess the water flow's impact on the building's structural integrity.
- Contact the communications center for further instructions.
- Evacuate the building to prevent potential water damage.
- Perform a 360-degree size up, locate outside risers, and check for water flow. (correct)
What should happen when a building with a fire alarm system does not have a functioning Knox Box?
What should happen when a building with a fire alarm system does not have a functioning Knox Box?
When responding to a fire alarm, what is a key action to take before silencing the alarm?
When responding to a fire alarm, what is a key action to take before silencing the alarm?
What should personnel do if, upon arrival at a fire alarm, a building representative is present?
What should personnel do if, upon arrival at a fire alarm, a building representative is present?
When should company officers consider the possibility of alternative access methods during emergency incidents?
When should company officers consider the possibility of alternative access methods during emergency incidents?
Which action is explicitly prohibited regarding fire alarm systems according to the guideline?
Which action is explicitly prohibited regarding fire alarm systems according to the guideline?
In the context of a water flow alarm, what is the protocol for gaining access into a structure if water flow is confirmed?
In the context of a water flow alarm, what is the protocol for gaining access into a structure if water flow is confirmed?
After silencing a fire alarm and no building representative is present, who should the Communications Center notify to contact the building representative?
After silencing a fire alarm and no building representative is present, who should the Communications Center notify to contact the building representative?
Flashcards
Purpose of SOG 100-03
Purpose of SOG 100-03
To establish procedures for response to fire alarms.
Initial Response Code
Initial Response Code
Upon dispatch to an automatic fire alarm, units shall respond Code 1.
First Arrival Actions
First Arrival Actions
Give an arrival report and check the building for fire, smoke, or water flow.
When to use Forcible Entry
When to use Forcible Entry
Signup and view all the flashcards
Alarm Annunciator Panel Check
Alarm Annunciator Panel Check
Signup and view all the flashcards
Knox Box Purpose
Knox Box Purpose
Signup and view all the flashcards
Communication with Building Representative
Communication with Building Representative
Signup and view all the flashcards
Water Flow Alarm Response
Water Flow Alarm Response
Signup and view all the flashcards
Water Flow Alarm Evaluation
Water Flow Alarm Evaluation
Signup and view all the flashcards
Scope of SOG 100-03
Scope of SOG 100-03
Signup and view all the flashcards
Study Notes
- Standard Operating Guideline (SOG) 100-03 applies to all Emergency Operations personnel.
- This SOG establishes procedures for response to fire alarms
Authority
- The Fire Rescue Administrator has authority over this guideline.
Response
- Units dispatched to an automatic fire alarm must respond Code 1.
- Company Officers have the option of responding Code 3 based on information from the Communications Center.
- If the Communications Center receives notification from a monitoring company about a false alarm and proper code, all responding units shall cancel.
- Responding units shall continue Code 1 to verify if the Communications Center receives notification from a business or homeowner that there is no emergency.
Arrival
- An arrival report must be given per SOG 210-01 Communications.
- A check of the building for fire, smoke, or water flow must be conducted.
- Access should be gained when the interior of the building is not readily visible from the exterior.
- Forcible entry should be used when no key or key holder is available, and there are indications of a fire.
- The alarm annunciator panel should be located.
- A check should be made for activated pull stations or smoke detectors.
- After searching the building for fire conditions, a fire alarm can be silenced.
- A fire alarm system must NOT be reset after silencing the alarm
Water Flow Alarms
- Units dispatched to automatic fire alarms reported as water flow alarms must respond Code 3.
- Personnel must perform a 360-degree size up.
- Personnel shall locate the outside risers and check the system to see if water flows.
- If a water flow is confirmed, personnel must gain access to the interior of the structure to evaluate the cause of the alarm.
Gaining Access
- All buildings in the county equipped with fire alarm systems must maintain building access keys in a Knox Box.
- If a building with a fire alarm system does not have a Knox Box or it is not operating, the area inspector within Bureau of Safety Services should be advised.
- If the proper keys are not in the Knox Box, the Company Officer should determine if a key holder can respond in a timely manner, or if there is an immediate need to force entry during an emergency or non-emergency incident.
Notification to Communication Center
- If a building representative is present, they should be advised of the problem, turn the building over to them for appropriate action, and the Communications Center needs to be advised.
- If no building representative is present, advise the Communications Center that the alarm has been silenced.
- The Communications Center must notify the monitoring company to contact the building representative so that the system can be serviced.