Fire Alarm Response
16 Questions
0 Views

Fire Alarm Response

Created by
@AstonishedOnomatopoeia

Questions and Answers

What code should units respond to upon dispatch to an automatic fire alarm?

  • Code 2
  • Code 1 (correct)
  • Code 4
  • Code 3
  • Under what circumstance may Company Officers choose to respond Code 3?

  • When a fire is suspected from the dispatch
  • Based on information from the Communications Center (correct)
  • If the alarm is a known false alarm
  • If responding units are nearby
  • What should happen if a monitoring company notifies the Communications Center that the fire alarm was false?

  • Verification of the alarm should be attempted
  • All responding units shall cancel (correct)
  • A Code 3 response should be initiated
  • All units should continue to the scene
  • When a business or homeowner indicates there is no emergency, what should the responding units do?

    <p>Continue Code 1 to verify the situation</p> Signup and view all the answers

    What is the first action taken upon arrival at the incident site?

    <p>Give an arrival report and check for hazards</p> Signup and view all the answers

    What should be done when the interior of the building is not visible from the exterior?

    <p>Gain access to the building</p> Signup and view all the answers

    When should forcible entry be utilized according to the guidelines?

    <p>When no key or key holder is available and fire is suspected</p> Signup and view all the answers

    What should be checked on the alarm annunciator panel upon arrival?

    <p>Activation of pull stations or smoke detectors</p> Signup and view all the answers

    What action should personnel take first upon arrival at a water flow alarm with no indications of fire from Side Alpha?

    <p>Locate the outside risers</p> Signup and view all the answers

    How should personnel respond to alerts of automatic fire alarms that are reported as water flow alarms?

    <p>Respond Code 3 and perform a 360-degree size up</p> Signup and view all the answers

    What should be done if a building with a fire alarm system does not have a Knox Box?

    <p>Notify the appropriate area inspector</p> Signup and view all the answers

    What should be verified to confirm actual water flow in response to a water flow alarm?

    <p>Check pressure gauges and water gong alarm</p> Signup and view all the answers

    If no building representative is present at the scene of an alarm, what should personnel do?

    <p>Advise the Communications Center that the alarm has been silenced</p> Signup and view all the answers

    In the case where the proper keys are not available in the Knox Box, what should the Company Officer do?

    <p>Determine if a keyholder can respond in a timely manner</p> Signup and view all the answers

    During a response to a water flow alarm, what is the primary reason for performing a size-up?

    <p>To evaluate potential fire hazards and building conditions</p> Signup and view all the answers

    What is the recommended action if a water flow is confirmed during an alarm response?

    <p>Complete interior inspection and evaluate the cause of the alarm</p> Signup and view all the answers

    Study Notes

    Purpose and Authority

    • Establishes procedures for response to fire alarms.
    • Authority vested in the Fire Rescue Administrator.

    Scope

    • Applies to all Emergency Operations personnel.

    Response Protocol

    • Units respond to automatic fire alarms Code 1.
    • Company Officers may use discretion to respond Code 3 if updated information is available.
    • If notified of a false alarm by a monitoring company, responding units shall cancel.
    • If informed by a business/homeowner that there is no emergency, units proceed Code 1 to verify.

    Arrival Procedures

    • Arrival reports follow SOG 210-01 Communications.
    • Conduct checks for fire, smoke, or water flow upon arrival.
    • Access should be gained if the building's interior is not visible from the exterior.
    • Forcible entry is permitted when no access is available and potential fire indications exist.
    • Locate the alarm annunciator panel and check for activated pull stations or smoke detectors.
    • After a thorough search, a fire alarm may be silenced; do not reset the fire alarm system.

    Water Flow Alarms

    • Units dispatched for water flow alarms respond Code 3.
    • Confirm fire status from Side Alpha; if clear, perform a 360-degree size up and locate outside risers.
    • Check for actual water flow using pressure gauges or alarms.
    • If water flow is confirmed, access the building to evaluate the cause of the alarm.

    Gaining Access

    • Buildings with fire alarm systems must maintain access keys in a Knox Box.
    • Report any missing or malfunctioning Knox Boxes to Bureau of Safety Services inspectors.
    • If proper keys are not available, determine if a key holder can respond or if forcible entry is necessary.

    Notification Procedures

    • If a building representative is present, inform them of the situation and hand over responsibilities.
    • If no representative is present, inform the Communications Center that the alarm has been silenced.