NBC 2015 - Section 9.10 - 02

UndisputedGrace avatar
UndisputedGrace
·
·
Download

Start Quiz

Study Flashcards

40 Questions

Which type of wall should be constructed to separate adjacent houses with a secondary suite from the rest of the building?

Firewall

What should be used to fill the space between the top of the wall and the roof deck?

Insulation

What is the minimum distance required between unprotected openings in exterior walls of a building meeting at an external angle of 135° or less?

1.2 m

What is the required thickness of gypsum board for finishing the interior of exterior walls within a certain distance of a dwelling unit, ancillary space, or common space in a house with a secondary suite?

12.7 mm

What type of material should be used for protection of soffits enclosing a projection less than 2.5 m vertically above a window or door?

Gypsum soffit board

Which type of appliances need to be separated from the remainder of the building by a fire separation with a 1-hour fire-resistance rating?

Fuel-fired appliances

What is the required fire-resistance rating for a fire separation separating a room for temporary storage of combustible refuse in all occupancies from the remainder of the building?

45 minutes

In which type of room are the fire-resistance rating requirements not applicable to the floor assembly immediately below it?

Service rooms

What is the minimum fire-resistance rating required for a fire separation separating a service room containing incinerators from the remainder of the building?

2 hours

Which type of rooms need to be separated from the remainder of the building by a fire separation with a fire-resistance rating of not less than 1 hour when the floor area containing the room is not sprinklered?

Service rooms

According to the National Building Code of Canada 2015, what is the minimum fire-resistance rating required for a fire separation between a public corridor and the remainder of the building?

1 h

In which types of occupancies is no fire-resistance rating required for fire separations between a public corridor and the remainder of the building?

Residential occupancies

What is the minimum width required for a public corridor to not require a fire separation from the remainder of the building?

5 m

What is the minimum fire-resistance rating required for a fire separation between a storage garage and other occupancies?

1.5 h

In which situation is an air barrier system required between a storage garage and the remainder of the building?

When the storage garage is attached to a residential building

Which type of piping is not allowed in any part of a drain, waste and vent piping system that penetrates a fire separation or membrane with a required fire-resistance rating?

Combustible piping

What is the requirement for combustible drain, waste and vent piping that is not located in a vertical shaft and penetrates a fire separation or membrane?

It must be sealed at the penetration with a fire stop

What is the required fire-resistance rating for the fire stop used to seal combustible drain, waste and vent piping that penetrates a fire separation or membrane?

Not less than the fire-resistance rating required for the fire separation

When is combustible drain piping permitted to penetrate a horizontal fire separation or membrane?

When it leads directly from a noncombustible watercloset through a concrete floor slab

In buildings containing 2 dwelling units only, where is combustible drain, waste and vent piping permitted on a horizontal fire separation?

On one side

Which one of the following materials is NOT suitable for a gypsum board application?

10 mm thick particleboard

Under what condition do the requirements in Sentence (2) not apply for a soffit described in Sentence (1) at the edge of an attic or roof space?

When the soffit is separated from the remainder of the attic or roof space by fire blocks

What is the condition under which the requirements of Sentence (2) do not apply for all suites spanned by a common attic or roof space or situated above or below the projecting floor?

When the suites are sprinklered

What types of rooms are exempt from the requirements of Sentence (2) if all suites spanned by a common attic or roof space or situated above or below the projecting floor are sprinklered?

Closets and hallways

What is the minimum thickness of lumber required for a gypsum board application?

11 mm

According to the National Building Code of Canada 2015, which of the following is required for combustible construction that abuts on or is supported by a noncombustible fire separation?

The collapse of the combustible construction will not cause collapse of the fire separation

According to the National Building Code of Canada 2015, what is the required total thickness of masonry and/or grout and/or concrete for pockets formed in a masonry or concrete fire separation for the support of beams or joists?

The remaining total thickness must be not less than the required equivalent thickness shown for Type S monolithic concrete in Table D-2.1.1.

According to the National Building Code of Canada 2015, what is the required fire-resistance rating for a horizontal service space or other concealed space located above a required vertical fire separation?

The space must be divided by an equivalent fire separation within the space

According to the National Building Code of Canada 2015, what is the required fire-resistance rating for a fire separation separating residential occupancies from all other major occupancies?

Not less than 1 h

According to the National Building Code of Canada 2015, what is the required fire-resistance rating for a fire separation separating dwelling units from the remainder of the building in a building containing a secondary suite?

Not less than 1 h

True or false: Gypsum board applications require a minimum thickness of 11 mm plywood?

False

True or false: The requirements in Sentence (2) do not apply to a soffit at the edge of an attic or roof space completely separated by fire blocks?

True

True or false: If all suites in a building are sprinklered, the requirements in Sentence (2) do not apply?

True

True or false: The thickness of lumber required for a gypsum board application is not less than 11 mm?

True

True or false: Combustible drain piping is permitted to penetrate a horizontal fire separation or membrane under certain conditions?

False

True or false: The fire-resistance rating required for a fire separation separating residential occupancies from all other major occupancies is 1 hour?

True

True or false: An air barrier system is required between a storage garage and the remainder of the building?

True

True or false: The required fire-resistance rating for the fire stop used to seal combustible drain, waste and vent piping is 1 hour?

False

True or false: A public corridor does not require a fire separation from the remainder of the building if it meets a minimum width?

False

True or false: Gypsum board is not suitable for a gypsum board application?

False

Test your knowledge on exhaust ducts serving more than one fire compartment. Learn about the requirements for fan placement and the prohibition of direct exhaust into the duct.

Make Your Own Quizzes and Flashcards

Convert your notes into interactive study material.

Get started for free

More Quizzes Like This

NBC 2015 - Section 9.10 - 01
40 questions
NBC 2015 - Section 9.10 - 05
40 questions
NBC 2015 - Section 9.11-13 - 01
40 questions
NBC -2015 - Section 9.27 - 01
40 questions
Use Quizgecko on...
Browser
Browser