NBC 2015 - Section 9.10 - 02
40 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

Which type of wall should be constructed to separate adjacent houses with a secondary suite from the rest of the building?

  • Vertical wall
  • Exterior wall
  • Firewall (correct)
  • Party wall
  • What should be used to fill the space between the top of the wall and the roof deck?

  • Wood
  • Insulation (correct)
  • Metal
  • Concrete
  • What is the minimum distance required between unprotected openings in exterior walls of a building meeting at an external angle of 135° or less?

  • 5 m
  • 12.7 mm
  • 1.2 m (correct)
  • 2.5 m
  • What is the required thickness of gypsum board for finishing the interior of exterior walls within a certain distance of a dwelling unit, ancillary space, or common space in a house with a secondary suite?

    <p>12.7 mm</p> Signup and view all the answers

    What type of material should be used for protection of soffits enclosing a projection less than 2.5 m vertically above a window or door?

    <p>Gypsum soffit board</p> Signup and view all the answers

    Which type of appliances need to be separated from the remainder of the building by a fire separation with a 1-hour fire-resistance rating?

    <p>Fuel-fired appliances</p> Signup and view all the answers

    What is the required fire-resistance rating for a fire separation separating a room for temporary storage of combustible refuse in all occupancies from the remainder of the building?

    <p>45 minutes</p> Signup and view all the answers

    In which type of room are the fire-resistance rating requirements not applicable to the floor assembly immediately below it?

    <p>Service rooms</p> Signup and view all the answers

    What is the minimum fire-resistance rating required for a fire separation separating a service room containing incinerators from the remainder of the building?

    <p>2 hours</p> Signup and view all the answers

    Which type of rooms need to be separated from the remainder of the building by a fire separation with a fire-resistance rating of not less than 1 hour when the floor area containing the room is not sprinklered?

    <p>Service rooms</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the minimum fire-resistance rating required for a fire separation between a public corridor and the remainder of the building?

    <p>1 h</p> Signup and view all the answers

    In which types of occupancies is no fire-resistance rating required for fire separations between a public corridor and the remainder of the building?

    <p>Residential occupancies</p> Signup and view all the answers

    What is the minimum width required for a public corridor to not require a fire separation from the remainder of the building?

    <p>5 m</p> Signup and view all the answers

    What is the minimum fire-resistance rating required for a fire separation between a storage garage and other occupancies?

    <p>1.5 h</p> Signup and view all the answers

    In which situation is an air barrier system required between a storage garage and the remainder of the building?

    <p>When the storage garage is attached to a residential building</p> Signup and view all the answers

    Which type of piping is not allowed in any part of a drain, waste and vent piping system that penetrates a fire separation or membrane with a required fire-resistance rating?

    <p>Combustible piping</p> Signup and view all the answers

    What is the requirement for combustible drain, waste and vent piping that is not located in a vertical shaft and penetrates a fire separation or membrane?

    <p>It must be sealed at the penetration with a fire stop</p> Signup and view all the answers

    What is the required fire-resistance rating for the fire stop used to seal combustible drain, waste and vent piping that penetrates a fire separation or membrane?

    <p>Not less than the fire-resistance rating required for the fire separation</p> Signup and view all the answers

    When is combustible drain piping permitted to penetrate a horizontal fire separation or membrane?

    <p>When it leads directly from a noncombustible watercloset through a concrete floor slab</p> Signup and view all the answers

    In buildings containing 2 dwelling units only, where is combustible drain, waste and vent piping permitted on a horizontal fire separation?

    <p>On one side</p> Signup and view all the answers

    Which one of the following materials is NOT suitable for a gypsum board application?

    <p>10 mm thick particleboard</p> Signup and view all the answers

    Under what condition do the requirements in Sentence (2) not apply for a soffit described in Sentence (1) at the edge of an attic or roof space?

    <p>When the soffit is separated from the remainder of the attic or roof space by fire blocks</p> Signup and view all the answers

    What is the condition under which the requirements of Sentence (2) do not apply for all suites spanned by a common attic or roof space or situated above or below the projecting floor?

    <p>When the suites are sprinklered</p> Signup and view all the answers

    What types of rooms are exempt from the requirements of Sentence (2) if all suites spanned by a common attic or roof space or situated above or below the projecting floor are sprinklered?

    <p>Closets and hallways</p> Signup and view all the answers

    What is the minimum thickness of lumber required for a gypsum board application?

    <p>11 mm</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, which of the following is required for combustible construction that abuts on or is supported by a noncombustible fire separation?

    <p>The collapse of the combustible construction will not cause collapse of the fire separation</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the required total thickness of masonry and/or grout and/or concrete for pockets formed in a masonry or concrete fire separation for the support of beams or joists?

    <p>The remaining total thickness must be not less than the required equivalent thickness shown for Type S monolithic concrete in Table D-2.1.1.</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the required fire-resistance rating for a horizontal service space or other concealed space located above a required vertical fire separation?

    <p>The space must be divided by an equivalent fire separation within the space</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the required fire-resistance rating for a fire separation separating residential occupancies from all other major occupancies?

    <p>Not less than 1 h</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the required fire-resistance rating for a fire separation separating dwelling units from the remainder of the building in a building containing a secondary suite?

    <p>Not less than 1 h</p> Signup and view all the answers

    True or false: Gypsum board applications require a minimum thickness of 11 mm plywood?

    <p>False</p> Signup and view all the answers

    True or false: The requirements in Sentence (2) do not apply to a soffit at the edge of an attic or roof space completely separated by fire blocks?

    <p>True</p> Signup and view all the answers

    True or false: If all suites in a building are sprinklered, the requirements in Sentence (2) do not apply?

    <p>True</p> Signup and view all the answers

    True or false: The thickness of lumber required for a gypsum board application is not less than 11 mm?

    <p>True</p> Signup and view all the answers

    True or false: Combustible drain piping is permitted to penetrate a horizontal fire separation or membrane under certain conditions?

    <p>False</p> Signup and view all the answers

    True or false: The fire-resistance rating required for a fire separation separating residential occupancies from all other major occupancies is 1 hour?

    <p>True</p> Signup and view all the answers

    True or false: An air barrier system is required between a storage garage and the remainder of the building?

    <p>True</p> Signup and view all the answers

    True or false: The required fire-resistance rating for the fire stop used to seal combustible drain, waste and vent piping is 1 hour?

    <p>False</p> Signup and view all the answers

    True or false: A public corridor does not require a fire separation from the remainder of the building if it meets a minimum width?

    <p>False</p> Signup and view all the answers

    True or false: Gypsum board is not suitable for a gypsum board application?

    <p>False</p> Signup and view all the answers