Questions and Answers

What does one sound of the buzzer system in older apparatus indicate?

  • Go
  • Stop (correct)
  • Acknowledge signal
  • Reverse
  • What is the maximum weight limit for a tiller?

  • 80,000 lbs (correct)
  • 60,000 lbs
  • 120,000 lbs
  • 100,000 lbs
  • How many braking axles do tillers have?

  • 3 (correct)
  • 6
  • 5
  • 4
  • When positioning an apparatus near a building with overhead wires, what is the ideal distance to position it away from the building?

    <p>25 to 30 ft</p> Signup and view all the answers

    What is one of the most difficult maneuvers in a tiller?

    <p>Right hand turns from a dedicated right hand turn lane with a vehicle on the left</p> Signup and view all the answers

    What must be applied on tillers before operating the aerial?

    <p>Parking brake and trailer brake</p> Signup and view all the answers

    Where should the driver position the dual axles when operating the aerial ladder?

    <p>On the spot from which they view the ladder extending</p> Signup and view all the answers

    What is recommended when using chocks for tillers?

    <p>Place chocks both ahead of and behind the front steering axles</p> Signup and view all the answers

    When extending the aerial over a roof, how far should the bottom of the ladder be above the roof edge?

    <p>3 to 6 inches</p> Signup and view all the answers

    What is the recommended extension of the aerial above the edge of the roof?

    <p>3 to 6 rungs</p> Signup and view all the answers

    What should personnel do if the aerial comes in contact with powerlines?

    <p>Remain off the apparatus until power is shut off or aerial is freed from contact</p> Signup and view all the answers

    What is the typical balcony rail height?

    <p>4 ft</p> Signup and view all the answers

    How far should the aerial be extended past the base section's sixth rung to keep the tip of the fly section clear?

    <p>55 ft</p> Signup and view all the answers

    What length of roof ladder can help victims make the transition onto the aerial?

    <p>14 ft</p> Signup and view all the answers

    How often should hydraulic reservoirs be checked?

    <p>At least weekly</p> Signup and view all the answers

    What size of particles can the integral filter in the hydraulic reservoir clean the oil of?

    <p>10 microns</p> Signup and view all the answers

    What is the advantage of double-acting cylinders in hydraulic systems?

    <p>Allows the unit to fly below the 0-degree grade and still have enough power to lift the aerial back up</p> Signup and view all the answers

    What is the bottom section of the ladder called?

    <p>Base section</p> Signup and view all the answers

    What is most often responsible for damaging jack plates?

    <p>Road potholes and railroad crossings</p> Signup and view all the answers

    Which hydraulic system is the largest and most powerful on the aerial apparatus?

    <p>Lift cylinders</p> Signup and view all the answers

    What is the minimum flow on an aerial device, per NFPA standards?

    <p>1,000 gpm</p> Signup and view all the answers

    How many cavities does a hydroelectric swivel have?

    <p>3 cavities</p> Signup and view all the answers

    What is the minimum outer diameter recommended for rungs on the ladder?

    <p>1.25&quot;</p> Signup and view all the answers

    How much weight should each rung of the ladder be capable of supporting at the center?

    <p>250 lbs</p> Signup and view all the answers

    What is the minimum required width between handrails at the top of the ladder?

    <p>18 inches</p> Signup and view all the answers

    How much flow can the water curtain underneath the platform handle in case of impinging fire?

    <p>75 gpm</p> Signup and view all the answers

    What is the maximum angle newer aerials are capable of operating at?

    <p>-10 to +75 degrees</p> Signup and view all the answers

    How is the working height of the unit measured?

    <p>From the ground to the highest ladder rung at full elevation</p> Signup and view all the answers

    What does the red zone on level indicators signify?

    <p>Exceeding safe limits, operations should not continue</p> Signup and view all the answers

    What does the green zone on level indicators signify?

    <p>between 0 and 3.5 degrees, operates at 100% capacity</p> Signup and view all the answers

    What does the yellow zone indicate?

    <p>between 3.5 and 6 degrees, operates at 50% capacity</p> Signup and view all the answers

    In what order should new drivers operate the ladder?

    <p>Raise, rotate, extend</p> Signup and view all the answers

    What happens if a driver over pumps the aerial?

    <p>Excess water is vented to the ground</p> Signup and view all the answers

    When does NDT testing need to be done?

    <p>Every 5 years</p> Signup and view all the answers

    When does a time trial with the ladder start and end?

    <p>Starts when the ladder is lifted from the cradle, ends after all three functions are completed</p> Signup and view all the answers

    Where is it recommended to rotate during the rotation phase?

    <p>To the side of the control pedestal</p> Signup and view all the answers