Chiller Optimization Energy Savings Overview
19 Questions
0 Views

Chiller Optimization Energy Savings Overview

Created by
@TrendyElf

Questions and Answers

What is the primary purpose of the intelligent Chiller Control System?

  • To automate the chiller's physical maintenance
  • To increase the internal temperature of the building
  • To improve the aesthetic design of the building
  • To reduce energy usage while maintaining thermal comfort (correct)
  • Which sensors are utilized to determine the facility's heat load?

  • Relative Humidity sensors and Temperature sensors (correct)
  • Flow sensors and Thermocouples
  • Pressure sensors and humidity sensors
  • Motion sensors and Light sensors
  • Where are the Resistance Temperature Detectors (RTDs) located?

  • On the external walls of the building
  • Above the ceiling tiles in office spaces
  • At the entrance of the building
  • In the chilled water and condenser water piping system (correct)
  • What aspect of the building environment does the Chiller Optimization system maintain?

    <p>Internal thermal comfort</p> Signup and view all the answers

    When is the Chiller Optimization proposal scheduled to take place?

    <p>July 2024</p> Signup and view all the answers

    What is the primary goal of implementing a chiller optimization system?

    <p>To increase the lifespan of chiller components</p> Signup and view all the answers

    What percentage of energy savings is estimated when implementing a chiller optimization system?

    <p>8%-15%</p> Signup and view all the answers

    What was the average monthly saving at Wisma TNB Jalan Timur?

    <p>RM9,556.66</p> Signup and view all the answers

    Which location achieved the highest average monthly savings among the examples provided?

    <p>Penang International Airport</p> Signup and view all the answers

    How much CO2 was avoided at Wisma TNB Jalan Timur due to energy savings?

    <p>70,655.99 KgCO2</p> Signup and view all the answers

    What was the total annual saving achieved at Penang International Airport?

    <p>RM135,338.41</p> Signup and view all the answers

    What average percentage saving did TNB MITC achieve?

    <p>14.5%</p> Signup and view all the answers

    Which month showed the highest saving percentage at Wisma TNB Jalan Timur?

    <p>December</p> Signup and view all the answers

    What was the total CO2 avoidance for Penang International Airport?

    <p>337,195.20 KgCO2</p> Signup and view all the answers

    In which month did TNB MITC achieve the lowest saving percentage?

    <p>February</p> Signup and view all the answers

    What is the average monthly saving at TNB MITC?

    <p>RM8,440.59</p> Signup and view all the answers

    What is the purpose of the Total Heat Gain Factor Method?

    <p>To optimize cooling efficiency</p> Signup and view all the answers

    What was the total saving at TNB MITC over the measured period?

    <p>RM67,524.74</p> Signup and view all the answers

    What common benefit is associated with chiller optimization systems?

    <p>Reduced energy consumption</p> Signup and view all the answers

    Study Notes

    Chiller Optimization Overview

    • Intelligent Chiller Control System operates as the main controller for chillers, aiming to lower energy consumption while ensuring occupant comfort.
    • Monitors heat load through strategically placed Relative Humidity (RH) and Temperature sensors, along with Resistance Temperature Detectors (RTDs) in water piping.
    • Benefits include a reduction in energy usage and an increased lifespan of chiller components.
    • Estimated energy savings range from 8% to 15%.

    Case Studies of Energy Savings

    • Wisma TNB Jalan Timur

      • Average monthly savings of RM9,556.66, totaling RM114,679.90 annually.
      • Achieved a CO2 avoidance of 70,655.99 KgCo2.
      • Monthly savings varied from 9.90% to 27.1% across different months.
    • Penang International Airport

      • Monthly savings averaged RM22,556.40, with a total saving of RM135,338.41.
      • CO2 avoidance reached 234,013.33 KgCo2.
      • Monthly savings ranged from 8.69% to 16.2%, indicating significant energy efficiency.
    • TNB MITC

      • Average monthly savings of RM8,440.59, resulting in total savings of RM67,524.74.
      • CO2 avoidance documented at 54,010 KgCo2.
      • Monthly savings percentages fluctuated from 11.37% to 19.72%.

    Energy and Environmental Impact

    • Chiller optimization leads to significant reductions in energy consumption, contributing to environmental sustainability.
    • Systems implemented resulted in substantial CO2 reductions in multiple facilities, underscoring the environmental benefits of energy efficiency initiatives.
    • Continual monitoring and optimizing chiller performance directly link to improved operational costs and ecological responsibility in energy use.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Explore the intelligent control systems for chillers that enhance energy efficiency while maintaining occupant comfort. This quiz delves into case studies, highlighting significant energy savings and CO2 reduction achieved at various facilities like Wisma TNB and Penang International Airport.