Which voltage options are available for barriers with no hand generator?
Which voltage options are available for barriers with no hand generator?
- 110V AC and 24V/110V DC (correct)
- 110V AC and 24V DC
- 110V DC and 24V DC
- 24V AC and 110V DC
What is the maximum operation time for the barriers at 75% rated voltage?
What is the maximum operation time for the barriers at 75% rated voltage?
- 20 seconds (correct)
- 15 seconds
- 10 seconds
- 30 seconds
What safety feature protects against unauthorized access?
What safety feature protects against unauthorized access?
- Emergency operation capability
- Fail-safe locking mechanism
- Positive boom locking proving system (correct)
- Fracture segment
What is the shape of the boom used in the barriers?
What is the shape of the boom used in the barriers?
Which component provides power indication on the control panel?
Which component provides power indication on the control panel?
What is the normal operating current for a 110V AC motor?
What is the normal operating current for a 110V AC motor?
What feature assists in the gradual movement of the boom?
What feature assists in the gradual movement of the boom?
Which of the following is NOT part of the routine testing requirements?
Which of the following is NOT part of the routine testing requirements?
What feature is included in the hand generator version of the control panel?
What feature is included in the hand generator version of the control panel?
What is the maximum total length available for the boom construction?
What is the maximum total length available for the boom construction?
Which of the following correctly describes the operational sequence for using the barriers?
Which of the following correctly describes the operational sequence for using the barriers?
What type of insulation is specified for the motor?
What type of insulation is specified for the motor?
What feature allows for emergency operation of the barriers?
What feature allows for emergency operation of the barriers?
Which option denotes the function of the snubbing device in the system?
Which option denotes the function of the snubbing device in the system?
Which operating current is associated with a 24V DC motor?
Which operating current is associated with a 24V DC motor?
What is the primary purpose of the fracture segment in the barriers?
What is the primary purpose of the fracture segment in the barriers?
What feature differentiates the barriers with a hand generator from those without?
What feature differentiates the barriers with a hand generator from those without?
What type of test is performed as part of the acceptance tests for the barriers?
What type of test is performed as part of the acceptance tests for the barriers?
Barriers without hand generator operate at either ______ AC or 24V/110V DC.
Barriers without hand generator operate at either ______ AC or 24V/110V DC.
The boom is made of galvanized iron sheet and has an ______ shape.
The boom is made of galvanized iron sheet and has an ______ shape.
The maximum total length available for the boom is ______.
The maximum total length available for the boom is ______.
The operating sequence starts with opening detection contacts and unlocking the ______.
The operating sequence starts with opening detection contacts and unlocking the ______.
The operating current for a 110V AC motor is ______ normal.
The operating current for a 110V AC motor is ______ normal.
One of the safety features includes a fail-safe locking mechanism in both vertical and ______ positions.
One of the safety features includes a fail-safe locking mechanism in both vertical and ______ positions.
A generator/push button ______ switch is part of the hand generator version of the control panel.
A generator/push button ______ switch is part of the hand generator version of the control panel.
The boom position indicators are located on the ______ panel.
The boom position indicators are located on the ______ panel.
The operation time for the barriers is less than ______ seconds at rated voltage.
The operation time for the barriers is less than ______ seconds at rated voltage.
Routine tests include visual inspection and high ______ test.
Routine tests include visual inspection and high ______ test.
Match the operating positions with their corresponding angles:
Match the operating positions with their corresponding angles:
Match the types of barriers with their voltage specifications:
Match the types of barriers with their voltage specifications:
Match the parts of the control panel with their functions:
Match the parts of the control panel with their functions:
Match the motor specifications with their characteristics:
Match the motor specifications with their characteristics:
Match the safety features with their descriptions:
Match the safety features with their descriptions:
Match the components in the testing requirements with their types of tests:
Match the components in the testing requirements with their types of tests:
Match the motor operating currents with their corresponding voltage types:
Match the motor operating currents with their corresponding voltage types:
Match the features of the boom with their details:
Match the features of the boom with their details:
Match the operation time specifications with their descriptions:
Match the operation time specifications with their descriptions:
Match the elements associated with emergency operation with their features:
Match the elements associated with emergency operation with their features:
Flashcards
Automatic Boom Barriers
Automatic Boom Barriers
Automatic barrier systems that use a motor to raise and lower a boom barrier to block traffic. These barriers are often used in parking garages, toll booths, and other controlled access points.
Barrier without Hand Generator
Barrier without Hand Generator
A type of automatic boom barrier that operates solely on electricity, typically 110V AC or 24V/110V DC.
Barrier with Hand Generator
Barrier with Hand Generator
A type of automatic boom barrier that is powered by an internal hand generator, providing an alternative power source in case of power outages.
Boom Barrier Operating Sequence
Boom Barrier Operating Sequence
Signup and view all the flashcards
Open Position
Open Position
Signup and view all the flashcards
Closed Position
Closed Position
Signup and view all the flashcards
Operation Time
Operation Time
Signup and view all the flashcards
Boom Construction
Boom Construction
Signup and view all the flashcards
Fracture Segment
Fracture Segment
Signup and view all the flashcards
Control Panel
Control Panel
Signup and view all the flashcards
Study Notes
Types and Operation
- Two barrier types are available: one without a hand generator (110V AC or 24V/110V DC), and one with a hand generator (24V/110V DC).
- Operating sequence begins with opening detection contacts and unlocking the boom. Then, the boom moves, and finally, the boom locks in position and closes the detection contacts.
- Open position: 85-90 degrees from horizontal.
- Closed position: 0-2 degrees from horizontal.
- Operation time is less than 12 seconds at rated voltage, but can be up to 20 seconds at 75% rated voltage.
Technical Specifications
Boom Construction
- Boom is made of galvanized iron sheet in an octagonal shape.
- Available in 4 sections, each 2.44 meters long, with total lengths of 4.88m, 7.32m, or 9.76m.
- Sections are painted with alternating 300mm black and yellow bands.
- A red disc (600mm diameter) with a STOP sign is featured.
- Includes an LED boom light with a built-in fuse in the center.
Motor Specifications
- Class B insulation.
- Short-time 10-minute rating.
- Rotation in both directions.
- Overload protection using special MCBs.
- Varying operating current based on type:
- AC (110V): 2.5A normal, 4A maximum
- DC (24V): 4A normal, 7A maximum
- DC (110V): 1A normal, 1.8A maximum
Safety Features
- Fail-safe locking in both vertical and horizontal positions.
- Fracture segment for protection against impacts.
- Snubbing device for gradual boom movement.
- Emergency operation capability.
- Protection against unauthorized access.
- Positive boom locking.
Control and Monitoring
- Control panel includes power indication; open/close push buttons; emergency operation button; boom position indicators; and lock status indicators.
- Hand generator version includes a generator/push button selector switch and integrated control panel option.
Testing Requirements
Types of Tests
- Routine tests include visual inspection, high-voltage test, and insulation resistance test.
- Performance tests are also conducted.
- Acceptance tests follow the same routine as routine tests, utilizing a sampling plan.
- Type tests are also part of the testing requirements.
Warranty and Documentation
- 24 months warranty from supply, or 12 months from commissioning.
- Installation and maintenance manual provided.
- Tool kit included.
- Optional spare parts available.
Installation Requirements
- Road clearance is 0.8 to 1 meter.
- Weatherproof construction is required.
- Proper lubrication points should be maintained.
- Adequate cable protection is crucial.
- Secure locking mechanisms are essential.
Environmental Testing
- Life testing (100,000 cycles) and additional performance parameters are included in environmental testing.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
Test your knowledge on barrier types and their operation sequences. Explore the technical specifications of boom construction and motor details, including dimensions and materials used. This quiz will challenge your understanding of these critical components in barrier technology.