This document provides detailed information about the types, operation, and technical specifications of LC Gate barriers. It covers aspects like operating sequences, boom construction, motor specifications, safety features, control and monitoring, testing, warranty, and installation requirements. The document is likely a technical manual for the product.

Full Transcript

Types and Operation \- Two types available: \- Barriers without hand generator (110V AC or 24V/110V DC) \- Barriers with hand generator (24V/110V DC) \- Operating sequence: 1\. Open detection contacts and unlock boom 2\. Move boom 3\. Lock boom in position and close detection contacts \- Ope...

Types and Operation \- Two types available: \- Barriers without hand generator (110V AC or 24V/110V DC) \- Barriers with hand generator (24V/110V DC) \- Operating sequence: 1\. Open detection contacts and unlock boom 2\. Move boom 3\. Lock boom in position and close detection contacts \- Operating positions: \- Open position: 85-90 degrees from horizontal \- Closed position: 0-2 degrees from horizontal \- Operation time: Less than 12 seconds at rated voltage, maximum 20 seconds at 75% rated voltage \#\# Technical Specifications \#\#\# Boom Construction \- Made of galvanized iron sheet, octagonal shape \- Maximum 4 sections, each 2.44m long \- Total lengths available: 4.88m, 7.32m, or 9.76m \- Painted with alternating 300mm black and yellow bands \- Features red disc (600mm diameter) with STOP sign \- LED boom light with built-in fuse at center \#\#\# Motor Specifications \- Class B insulation \- Short time 10-minute rating \- Rotation in both directions \- Protection against overload using special MCBs \- Operating current varies by type: \- AC (110V): 2.5A normal, 4A maximum \- DC (24V): 4A normal, 7A maximum \- DC (110V): 1A normal, 1.8A maximum \#\# Safety Features \- Fail-safe locking in vertical and horizontal positions \- Fracture segment for protection against impacts \- Snubbing device for gradual movement \- Emergency operation capability \- Protection against unauthorized access \- Positive boom locking proving system \#\# Control and Monitoring \- Control panel with: \- Power indication \- Open/Close push buttons \- Emergency operation button \- Boom position indicators \- Lock status indicators \- Additional features for hand generator version: \- Generator/Push button selector switch \- Integrated control panel option \#\# Testing Requirements \#\#\# Types of Tests 1\. Routine Tests \- Visual inspection \- High voltage test \- Insulation resistance test \- Performance test 2\. Acceptance Tests \- Same as routine tests with sampling plan 3\. Type Tests \- Environmental testing \- Life testing (100,000 cycles) \- Additional performance parameters \#\# Warranty and Documentation \- 24 months from supply or 12 months from commissioning \- Installation and maintenance manual provided \- Tool kit included \- Optional spare parts available \#\# Installation Requirements \- Road clearance: 0.8 to 1 meter \- Weather-proof construction \- Proper lubrication points \- Adequate cable protection \- Secure locking mechanisms

Use Quizgecko on...
Browser
Browser