Army Maintenance (AR 750-1 & DA PAM 750-1) Quiz
20 Questions
100 Views

Army Maintenance (AR 750-1 & DA PAM 750-1) Quiz

Created by
@WellRunHydrogen

Questions and Answers

What DA PAM covers the army maintenance management system (TAMMS)?

DA PAM 750-8

What DA PAM is the guide for motor pool operations?

DA PAM 750-35

What regulation covers the army materials maintenance policy?

AR 750-1

What DA PAM is the leaders unit maintenance handbook?

<p>DA PAM 750-1</p> Signup and view all the answers

What are the 4 levels of maintenance?

<p>Unit, Direct support (DS), General support (GS), Depot</p> Signup and view all the answers

What does PMCS stand for?

<p>Preventive maintenance checks and service</p> Signup and view all the answers

When is a PMCS required to be performed?

<p>Before, during, and after the operation of a piece of equipment and also at weekly and monthly intervals</p> Signup and view all the answers

What is a TM?

<p>A technical manual, outlines the specific scope of repairs on equipment</p> Signup and view all the answers

What is a DD Form 314?

<p>Preventive maintenance schedule and record</p> Signup and view all the answers

What forms are contained in the equipment record folder when the vehicle is dispatched?

<p>DA form 2404, DA form 2408-14, SF 91, DD Form 518, DA form 5987</p> Signup and view all the answers

Who is required to perform a PMCS?

<p>Every operator who is assigned a piece of equipment</p> Signup and view all the answers

What does TAMMS stand for?

<p>The army maintenance management system</p> Signup and view all the answers

What is the DA form 2407 used for?

<p>To request support maintenance on a piece of equipment</p> Signup and view all the answers

What type of manual is used to perform operator level PMCS?

<p>The operators manual (10 series)</p> Signup and view all the answers

What is a class 1 leak?

<p>Seepage of fluid not great enough to form drops</p> Signup and view all the answers

What is a class 2 leak?

<p>Seepage of fluid great enough to form drops, but not great enough to cause the drops to fall during inspection</p> Signup and view all the answers

What is a class 3 leak?

<p>Seepage of fluid great enough to form drops and drip during inspection</p> Signup and view all the answers

What does PLL mean?

<p>Prescribed load list</p> Signup and view all the answers

How many days does a basic PLL sustain a unit?

<p>15 days</p> Signup and view all the answers

What does the acronym MAIT stand for?

<p>Maintenance assistance and instruction team</p> Signup and view all the answers

Study Notes

Army Maintenance Management System

  • DA PAM 750-8 details the Army maintenance management system (TAMMS).
  • AR 750-1 outlines the Army materials maintenance policy.
  • DA PAM 750-1 serves as the leaders' unit maintenance handbook.

Motor Pool Operations

  • DA PAM 750-35 guides motor pool operations.

Levels of Maintenance

  • Four levels exist:
    • Unit
    • Direct Support (DS)
    • General Support (GS)
    • Depot

Preventive Maintenance Checks and Services (PMCS)

  • PMCS stands for Preventive Maintenance Checks and Services.
  • Required before, during, and after equipment operation, as well as weekly and monthly.

Technical Manuals

  • A Technical Manual (TM) provides specific repair guidance for equipment.
  • The Operator's Manual (10 series) is used for operator-level PMCS.

Maintenance Documentation

  • DD Form 314 is used for preventive maintenance scheduling and records.
  • The following forms are included in equipment record folders upon vehicle dispatch:
    • DA Form 2404
    • DA Form 2408-14
    • SF 91
    • DD Form 518
    • DA Form 5987

Operator Responsibilities

  • Every assigned equipment operator is required to perform a PMCS.

Leak Classification

  • Class 1 Leak: Seepage not enough to form drops.
  • Class 2 Leak: Seepage forms drops but does not cause them to fall during inspection.
  • Class 3 Leak: Seepage forms drops and drips during inspection.

Prescribed Load List (PLL)

  • PLL stands for Prescribed Load List.
  • A basic PLL sustains a unit for 15 days.

Maintenance Assistance

  • MAIT stands for Maintenance Assistance and Instruction Team.

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

Description

Test your knowledge on Army maintenance management systems, including key DA PAMs and regulations such as AR 750-1. This quiz covers topics like motor pool operations and unit maintenance handbooks. Perfect for military personnel and students of Army regulations.

More Quizzes Like This

Log Abastecimiento
47 questions

Log Abastecimiento

GratefulOpal8609 avatar
GratefulOpal8609
Maintenance DA PAM 750-8 Flashcards
24 questions
Use Quizgecko on...
Browser
Browser