Podcast
Questions and Answers
What is the primary purpose of the Automatic External Defibrillator (AED) program instituted by the Kansas City Missouri Police Department?
What is the primary purpose of the Automatic External Defibrillator (AED) program instituted by the Kansas City Missouri Police Department?
- To provide early defibrillation to cardiac arrest victims. (correct)
- To serve as a substitute for Emergency Medical Services.
- To educate the public about cardiovascular health.
- To replace traditional CPR techniques in emergencies.
Who has the authority for overseeing all AED programs in Kansas City, Missouri?
Who has the authority for overseeing all AED programs in Kansas City, Missouri?
- The fire chief.
- The EMS Medical Director. (correct)
- The local police chief.
- City council members.
Which of the following is NOT indicated as a guideline for using an AED?
Which of the following is NOT indicated as a guideline for using an AED?
- The AED is vital within the first critical moments after cardiac arrest.
- The AED is intended for immediate use in emergencies.
- The AED should be utilized while awaiting EMS.
- The AED can be used independently of EMS. (correct)
What critical timeframe is emphasized for the use of an AED on cardiac arrest victims?
What critical timeframe is emphasized for the use of an AED on cardiac arrest victims?
Which regulatory body outlines the requirements for the AED program as per the directive?
Which regulatory body outlines the requirements for the AED program as per the directive?
What is the main legislative reference concerning the AED guidelines mentioned?
What is the main legislative reference concerning the AED guidelines mentioned?
Which aspect of the AED program is emphasized as essential in emergency situations?
Which aspect of the AED program is emphasized as essential in emergency situations?
According to the guidelines, how does the use of an AED relate to other emergency medical care?
According to the guidelines, how does the use of an AED relate to other emergency medical care?
What is required for the maintenance and operation of an AED in Kansas City, Missouri?
What is required for the maintenance and operation of an AED in Kansas City, Missouri?
How often does the Director conduct the re-approval process for AED program requirements?
How often does the Director conduct the re-approval process for AED program requirements?
Who is ultimately responsible for ensuring compliance with the AED program in Kansas City?
Who is ultimately responsible for ensuring compliance with the AED program in Kansas City?
Which items are specifically mentioned as being replaceable in the context of AED maintenance?
Which items are specifically mentioned as being replaceable in the context of AED maintenance?
What role does BOU play in the AED program maintenance?
What role does BOU play in the AED program maintenance?
Who is responsible for the proper functioning and charging of AEDs issued for Department vehicles?
Who is responsible for the proper functioning and charging of AEDs issued for Department vehicles?
What is the duration of validity for AED certification after course completion?
What is the duration of validity for AED certification after course completion?
Which entity is responsible for providing AED training and re-certification for department members?
Which entity is responsible for providing AED training and re-certification for department members?
What must members include in their request for replacement AED supplies?
What must members include in their request for replacement AED supplies?
What should be done with AEDs that are found to be non-functioning?
What should be done with AEDs that are found to be non-functioning?
Why must portable AEDs be brought inside at the end of each member’s shift?
Why must portable AEDs be brought inside at the end of each member’s shift?
Which section handles the purchase of AED replacements?
Which section handles the purchase of AED replacements?
What is the primary responsibility of members regarding their AED certifications?
What is the primary responsibility of members regarding their AED certifications?
What is the first step to take when a division receives a new AED?
What is the first step to take when a division receives a new AED?
What should be included on the form when registering a replacement AED?
What should be included on the form when registering a replacement AED?
How often should inspections of AEDs be conducted?
How often should inspections of AEDs be conducted?
What is required to be affixed to each AED?
What is required to be affixed to each AED?
What information should be used for the 'Facility Name' in undercover operations?
What information should be used for the 'Facility Name' in undercover operations?
How frequently must AEDs be tested according to the guidelines?
How frequently must AEDs be tested according to the guidelines?
Who is responsible for completing the AED Maintenance/Inspection Record?
Who is responsible for completing the AED Maintenance/Inspection Record?
What must be made available to the Director upon request?
What must be made available to the Director upon request?
What legal protection is provided to individuals who render emergency care using an AED?
What legal protection is provided to individuals who render emergency care using an AED?
What should be the first action taken when an AED is needed?
What should be the first action taken when an AED is needed?
What is the protocol once emergency medical services have taken over after AED usage?
What is the protocol once emergency medical services have taken over after AED usage?
Which of the following statements regarding the operation of an AED is correct?
Which of the following statements regarding the operation of an AED is correct?
If a member is not trained or certified in AED use, what should they do?
If a member is not trained or certified in AED use, what should they do?
What is a key responsibility of the Building Operations Unit (BOU) regarding AEDs?
What is a key responsibility of the Building Operations Unit (BOU) regarding AEDs?
Which action decreases the likelihood of survivability in an emergency situation involving an AED?
Which action decreases the likelihood of survivability in an emergency situation involving an AED?
What should be included in the AED Event Report after it is completed?
What should be included in the AED Event Report after it is completed?
Flashcards are hidden until you start studying
Study Notes
Automatic External Defibrillation (AED) Program Overview
- The Kansas City Missouri Police Department implements an AED program to aid first responders in delivering early defibrillation for sudden cardiac arrest victims.
- The program is governed by guidelines established by the Office of the EMS Medical Director.
- Authority for overseeing AED programs in Kansas City is delegated to the EMS Medical Director, under local and state statutes.
General Guidelines
- AEDs are a supplementary tool and do not replace Emergency Medical Services (EMS) care.
- Members providing emergency care with an AED in good faith are protected from civil liability, except in cases of willful misconduct.
AED Operation Procedures
- Contact trained personnel promptly without delaying emergency treatment for AED operation.
- Lifesaving measures should proceed, possibly including AED usage, regardless of specific training status.
- AEDs are user-friendly, guided by voice prompts during operation.
- Any AED usage must be reported to EMS immediately post-intervention.
- Completion of the AED Event Report (Form 259 P.D.) is required following the use of an AED.
Building Operations Unit (BOU) Responsibilities
- BOU oversees all fixed AEDs, including updates and audits to maintain compliance.
- New or replacement AEDs require a completed Public Access Defibrillator AED/PAD Program Application (Form 255 P.D.).
- Audits and inventory checks of AEDs must occur annually, with inspections and testing every 90 days.
Division Commander Responsibilities
- Division Commanders manage portable AEDs in Department vehicles and are responsible for applying inspection protocols.
- Regular checks of portable AEDs at the beginning of each shift ensure proper functionality.
- Portable AEDs must be stored indoors at shift end to avoid damage from extreme weather.
Training and Re-certification
- The Professional Training Division provides AED training and re-certification.
- Members must schedule re-certification to maintain eligibility, valid for two years post-training completion.
Supplies and Equipment Management
- Requests for replacement AED supplies must follow the established fiscal procedures.
- Replacement requests should include item specifics like brand, serial number, and location.
Compliance and Authorization
- The EMS Medical Director ensures adherence to all relevant statutes and ordinances.
- Authorization for AED operation in the City must be granted by the Medical Director, with re-approval conducted every two years.
Studying That Suits You