This document provides a work instruction for measuring the Vicat softening temperature of PMMA. It includes details on the procedure, safety precautions, and responsibilities for different roles in the process. The work instruction is intended for the Quality Control Department at Petro Rabigh.
Full Transcript
Petro Rabigh: Rabigh Refining & Petrochemical Company Work Instruction PMMA - Vicat Softening Temperature Engineering & Support Quality Control Department Issuing Organization QCD Polymer II Section Document No. Revision No. Effective Date PR/QCD/QCP2/WI-309 01 12/17/2022 Description Me...
Petro Rabigh: Rabigh Refining & Petrochemical Company Work Instruction PMMA - Vicat Softening Temperature Engineering & Support Quality Control Department Issuing Organization QCD Polymer II Section Document No. Revision No. Effective Date PR/QCD/QCP2/WI-309 01 12/17/2022 Description Me Date Signature Senior Chemist, QCD Polymer II Section 11/21/2022 Signed Reviewed By Rajab, Muhammad Hasbi J. Section Head, QCD Polymer II Section 12/06/2022 Signed Approved By Ghanemi, Adil I. Manager, Quality Control Department 12/11/2022 Signed Initiated By Name Job Title THAKKAR, RAKESHKUMAR P. Confidential Government Confidential Page 1 Restricted Company General Use Work Instruction PMMA - Vicat Softening Temperature Engineering & Support Quality Control Department Issuing Organization QCD Polymer II Section Document No. Revision No. Effective Date PR/QCD/QCP2/WI-309 01 12/17/2022 Table of content 1. Purpose ............................................................................................................................... 3 2. Scope .................................................................................................................................. 3 3. Abbreviations, Acronyms and Definitions ............................................................................. 3 4. Responsibilities / Impacted .................................................................................................. 3 5. Process / Instruction Description .......................................................................................... 4 6. Process / Flow Chart ............................................................................................................ 6 7. Forms for Records ................................................................................................................ 6 8. References .......................................................................................................................... 6 9. Document History ................................................................................................................ 7 10. Annexure............................................................................................................................. 7 Page 2 Work Instruction PMMA - Vicat Softening Temperature Engineering & Support Quality Control Department Issuing Organization QCD Polymer II Section Document No. Revision No. Effective Date PR/QCD/QCP2/WI-309 01 12/17/2022 1. Purpose This work instruction describes how to measure Vicat Softening Temperature of PMMA test specimen. 2. Scope This work instruction is applicable to PMMA test specimen. 3. Abbreviations, Acronyms and Definitions 3.1. Abbreviations: Abbreviations Description QCD Quality Control Department SSV Shift Supervisor PMMA Poly(methyl methacrylate) Lab Laboratory 3.2. Acronyms: Acronyms Description VST Vicat Softening Point T Temperature °C Celsius 4. Responsibilities / Impacted 4.1. QCD Polymer II Section, Section Head 4.1.1 Section Head is responsible to review the document and ensure it is up to date. 4.2. QCD Polymer II Section, Chemist 4.2.1 Chemist is responsible to ensure the communication, training and implementation of the work instructions within the section. Page 3 Work Instruction PMMA - Vicat Softening Temperature Engineering & Support Quality Control Department Issuing Organization QCD Polymer II Section Document No. Revision No. Effective Date PR/QCD/QCP2/WI-309 01 12/17/2022 4.3. QCD Polymer II Section, SSV 4.3.1 SSV is responsible to monitor the proper implementation of the work instructions within the section and report any related issues to SH or Chemists. 4.4. QCD Polymer II Section, Laboratory Technician 4.4.1 Laboratory technician is responsible to perform the analysis as per work instructions and proper housekeeping after completing the analysis. 5. Process / Instruction Description Overview A. Summary of the Method A flat-ended needle loaded with a specified mass (50 N) is placed in direct contact with a test specimen. The specimen and needle are heated at a rate of 50 + 5°C/hour. The temperature at which the needle (Flat-ended of 1 mm diameter circular) has penetrated a PMMA specimen to a depth of 1 mm is recorded as the vicat softening point. Vicat Softening Temperature gives idea about the thermal stability of PMMA. B. Safety : Use safety goggles, heat resistance gloves and safety shoes. The working area should be clean all the time. C. Apparatus: Heat Distortion Tester: Tinius Olsen 303HDTM D. Tools: Tweezer E. Reagents: Silicone oil with viscosity 100 CST Page 4 Work Instruction PMMA - Vicat Softening Temperature Engineering & Support Quality Control Department Issuing Organization QCD Polymer II Section Document No. Revision No. Effective Date PR/QCD/QCP2/WI-309 01 12/17/2022 Sr. No. Process / Instruction Description Responsibility Org Position 5.1. Preparation of test specimen QCD Polymer II Section Lab Technician Prepare PMMA test specimen (length X width X thickness) = (80 X 10 X 4 mm) following PR/QCD/QCP2/WI-308 procedure for Injection Molding for Test Pieces (and Annealing). 5.2. Select two test specimens for testing for each analysis. The test specimens surfaces shall be flat and parallel, no bending and free from flash and check the thickness of the specimens. QCD Polymer II Section Lab Technician 5.3. Measurement QCD Polymer II Section Lab Technician Press Raise switch to open the oil bath and sample holder then, put the specimen on sample holder. Adjust specimen in sample holder at the center of Needle. Lower the needle by turning nob from right to left. 5.4. Dip the specimen in oil bath by pressing lower switch. QCD Polymer II Section Lab Technician 5.5. Apply 6N weight first and then 40 N weight on sample holder. QCD Polymer II Section Lab Technician 5.6. Press start to increase temperature at the rate 50°C / hour. QCD Polymer II Section Lab Technician 5.7. After analysis completed , Press the result switch to check the result, result will be displayed on screen. Note down the result. QCD Polymer II Section Lab Technician Page 5 Reference Work Instruction PMMA - Vicat Softening Temperature Engineering & Support Quality Control Department Issuing Organization QCD Polymer II Section Document No. Revision No. Effective Date PR/QCD/QCP2/WI-309 01 12/17/2022 Sr. No. Process / Instruction Description Responsibility Org Position 5.8. Report QCD Polymer II Section Lab Technician Reference the results of VST in °C as whole number and enter the results in LIMS. 5.9. After cooling, remove the weight and press raise switch, turn nob from left to right and remove the sample from sample holder. Press Lower switch and close the oil bath. QCD Polymer II Section Lab Technician 5.10. Waste Disposal Dispose waste sample to the appropriate waste container. QCD Polymer II Section Lab Technician 5.11. Housekeeping After completing the analysis, perform the proper housekeeping in the area. QCD Polymer II Section Lab Technician 6. Process / Flow Chart This is not applicable 7. Forms for Records This is not applicable 8. References S. No. 1 Document Number OM-240-CH4-4-4-2 2 ISO 306 Page 6 Title / Description Vicat Softening Point Injection Molding Plastics — Thermoplastic materials — Determination of Vicat softening temperature (VST) Work Instruction PMMA - Vicat Softening Temperature Engineering & Support Quality Control Department Issuing Organization QCD Polymer II Section Document No. Revision No. Effective Date PR/QCD/QCP2/WI-309 01 12/17/2022 9. Document History Revision No. Revision Date Revision Summary Approvals (By Name) 00 10/10/2017 First Issue Initiated By Bassam Aljahdali Chemist, Yasunari Haishima Chemist., Reviewed By Muhammad Hasbi Section Head QCP-II Concurred By 01 12/11/2022 Review of document as per GI (General Instruction) PR/PCO/CPM/GI001 (Document and Record Management). Approved By Adil I. Ghanemi Manager QCD Initiated By THAKKAR, RAKESHKUMAR P. Senior Chemist, QCD Polymer II Section Reviewed By Rajab, Muhammad Hasbi J. Section Head,QCD Polymer II Section Concurred By Approved By 10. Annexure This is not applicable Page 7 Ghanemi, Adil I. Manager, Quality Control Department