Cold Water Mock 2 PDF - Plumbing Questions
Document Details
![AdvancedCourage8795](https://quizgecko.com/images/avatars/avatar-19.webp)
Uploaded by AdvancedCourage8795
Oaklands College
Tags
Summary
This document contains 42 plumbing questions about cold water systems, testing knowledge of installations, adequacy, and maintenance. Questions cover various aspects of cold water systems. Includes topics such as legal requirements, flow rates, and different types of valves.
Full Transcript
# COLD WATER MOCK 2 ## 1. The legal requirements for the installation of cold water services are stated in the * a) British Standards * b) Building Regulations * c) Water Regulations * d) Construction Regulations. ## 2. To establish whether a cold water supply to a dwelling is adequate to feed a...
# COLD WATER MOCK 2 ## 1. The legal requirements for the installation of cold water services are stated in the * a) British Standards * b) Building Regulations * c) Water Regulations * d) Construction Regulations. ## 2. To establish whether a cold water supply to a dwelling is adequate to feed all the plumbing appliances, the best item of equipment to use is a * a) water meter * b) manometer * c) flow meter * d) air test gauge. ## 3. A plumbing operative identifies that a low pressure cold water system does not provide a suitable flow rate to an electric shower, supplied by the plumbing company, that is to be installed. Who should be the first point of contact? * a) Water company. * b) Local authority. * c) Customer. * d) Supervisor. ## 4. Which one of the following is approved for use on underground service pipes? * a) Solder fittings with lead/tin solder. * b) Push fit plastic fittings. * c) Type 'B' compression fittings. * d) Type 'A' compression fittings. ## 5. The Water Regulations state that the minimum permissible distance from the external wall of a dwelling, to where an uninsulated service pipe enters the inside of the building, is * a) 150 mm * b) 250 mm * c) 550 mm * d) 750 mm. ## 6. The last isolation valve on a supply pipe to a cold water storage cistern is the * a) float operated valve * b) draining valve * c) servicing valve * d) supply stop valve. ## 7. The recommended clip spacing for a vertical cold water service pipe in 15 mm copper is * a) 1.0 m * b) 1.3 m * c) 1.5 m * d) 1.8 m. ## 8. Refer to Figure 1. The system component indicated by the British Standard symbol shown is a * a) supply stop valve * b) float valve * c) check valve * d) draining valve. ## 9. In addition to a warning pipe, an overflow pipe is required on cisterns of more than what capacity? * a) 115 litres. * b) 230 litres. * c) 1000 litres. * d) 1250 litres. ## 10. The main advantage of a direct system of cold water, compared to an indirect system of cold water, is that * a) there is much less chance of noise in the system * b) it has cheaper materials and installation costs * c) the pressure of the hot water is improved * d) the pressure to the float valves is reduced. ## 11. Which one of the following grades of copper pipework is permissible for use on underground service pipework? * a) R220 Micro-bore. * b) R250. * c) R220. * d) R290. ## 12. A distributing pipe in a cold water system * a) connects between the outlet of a cistern and a number of appliances * b) connects between the inlet of a cistern and a number of appliances * c) is supplied at mains pressure * d) is only used on private supplies. ## 13. The underground pipe that connects the water undertaker's main to the boundary stop valve is called the * a) rising main pipe * b) communication pipe * c) service pipe * d) cold feed pipe. ## 14. The correct method for making a joint between a float operated valve and the wall of a plastic cold water storage cistern, is to use * a) an oil based jointing compound with a stiffener plate * b) fabricated lead washers * c) a non-toxic silicon compound * d) plastic jointing washers with a stiffener plate. ## 15. The hydraulic soundness test specification on cold water supply and distributing pipes can be found in * a) the Water Regulations * b) the Building Regulations * c) BS 6281 * d) CP 312 Part 1. ## 16. When carrying out soundness testing, an interim test should * a) include a visual inspection of all components, pipework and fittings prior to starting the hydraulic test * b) be in the form of a pre-test using inert argon, so water damage would not occur should there be any leaks * c) be applied to every pipeline after completion of a particular section, particularly where the work will be covered * d) be carried out by a representative of the Water Company to ensure that the installation complies with Regulations. ## 17. On an indirect cold water system, the best method of isolating the supply to the cold tap on the bath, would be to turn off the * a) supply stop valve * b) cold distributing pipe service valve * c) cold feed service valve * d) service valve to the storage cistern. ## 18. Whilst removing pipework to a cold water storage cistern, a plumbing operative notices some damaged electrical cabling. The correct course of action is to * a) replace the defective cable immediately * b) phone an electrician to repair the cable * c) ignore it, as it is not their responsibility * d) isolate the circuit and report the fault to the supervisor. ## 19. Before work commences on moving an instantaneous shower to a new position, the plumber should * a) isolate the shower from the electrical supply using the pull switch in the bathroom, test that the shower is not live using a multi meter, then disconnect the cable * b) isolate the shower from the electrical supply by turning off all the power at the mains, disconnect the shower, tape the wires up, and turn the power back on * c) contact the power supply company and advise that the power is being turned off, then isolate the supply at the consumer unit by removing and retain the fuse * d) isolate the shower from the electrical supply at the consumer unit by removing and retaining the fuse, and test for safe isolation. ## 20. A cold water system is to be permanently de-commissioned. The best method of ensuring that the water supply can not be re-used is to turn off the * a) water supplier's stop valve located outside * b) supply stop valve and remove the crutch head * c) supply stop valve and cap off the supply pipe * d) supply stop valve and label 'do not turn on'. ## 21. It is advisable to place a warning notice on the supply stop valve when carrying out temporary system decommissioning, in a domestic dwelling * a) when re-washering a float valve fed via a service valve * b) when the supply stop valve is being maintained * c) where the supply may be off for some time * d) in all circumstances whatever the type of work. ## 22. Which one of the following would be the most appropriate to receive decommissioning records, for work carried out in a dwelling? * a) Customer. * b) Water undertaker. * c) Local Authority. * d) Architect. ## 23. Information on the maintenance requirements of an instantaneous shower can be obtained from the * a) installation materials specification * b) Water Regulations Guidelines * c) manufacturer's technical data * d) British Standard 6700: 1997. ## 24. Copper supply pipe is most at risk from corrosion when * a) jointed using brass fittings containing zinc * b) installed in roof spaces without correct insulation * c) clipped directly to a plasterboard stud partition * d) connected to polythene pipework below ground. ## 25. Before starting work on a lengthy maintenance job, a plumber's first action should be to * a) turn off the supply and tell the customer not to use the taps * b) advise the customer that the supply is going to be to be turned off * c) turn off the supply and drain down all the system pipework * d) make sure the system pipework has been thoroughly flushed out. ## 26. Refer to Figure 2 which shows an equilibrium float valve. The metering pin is indicated by the number * a) 1 * b) 2 * c) 3 * d) 4. ## 27. In which one of the following cold water components, can the valve seating be repaired? * a) Diaphragm float valve. * b) Spherical service valve. * c) Fullway gate valve. * d) Sink pillar tap. ## 28. Safe access equipment would usually need to be available when working on a * a) cold water storage cistern * b) water meter located externally * c) stop valve inside a kitchen unit * d) mixer valve connected to a bidet. ## 29. The performance specification for a shower pump can be found in the * a) job specification for the installation * b) current Building Regulations * c) current Water Regulations * d) manufacturer's technical literature. ## 30. British Standard 6700 provides specific guidance on the design, installation, testing and maintenance of * a) cold water services * b) condensing boilers * c) domestic gas supply * d) drainage systems. ## 31. The purpose of a packing gland on a stop valve is to * a) prevent the crutch head from being over tightened * b) provide a method of keeping the spindle lubricated * c) provide a seal between the spindle and the head gear * d) ensure that the stop valve cannot be tampered with. ## 32. Excessive water pressures in a cold water system can be controlled by fitting a pressure * a) amplifier * b) pumping kit * c) reducing valve * d) venture device. ## 33. A plumbing company has a contract to maintain the systems on a housing estate. Which one of the following documents would state the type of work required to be undertaken? * a) Materials schedule. * b) Maintenance specification. *c) Maintenance schedule. * d) Bill of Quantities. ## 34. The most likely cause of low water pressure on the cold water supply, to a kitchen sink tap in a direct system, is that * a) the cold water storage cistern is empty * b) a cold feed service valve is closed or faulty * c) there is a burst on the cold water supply * d) the service valve to the cistern float valve is closed. ## 35. Whilst working on a maintenance job, a plumber suspects that an underground supply pipe has burst. The most appropriate course of action would be to * a) locate the burst and repair it * b) advise the Local Water Company * c) advise the Local Authority Inspector * d) report the matter to the customer. ## 36. There is no supply to a hot water tap on the bath when it is opened. The cold water system is indirect. The most likely cause of the problem is a fault on the * a) primary flow * b) filling loop to the boiler * c) cold feed pipework * d) open vent pipe. ## 37. The water from the shower head of a low pressure thermostatic mixer valve is constantly cold. The most likely cause of the problem is that the * a) cold connection to the shower has been made directly to the supply pipe * b) cold distributing pipe is locked with air at a high point in the pipework * c) cold water storage cistern is not high enough above the mixer valve outlet * d) service valve on the cold distribution pipe to the shower is closed. ## 38. Other than a leaking pipe or fitting, the most probable cause of excessive moisture on exposed cold water copper pipework within a dwelling is * a) capillary action * b) condensation * c) electrolysis * d) evaporation. ## 39. A metal plate is required at the point where the float valve tail penetrates the wall of a plastic cold water storage cistern in order to * a) ensure a water tight joint is possible * b) increase stress on the float valve arm * c) prevent the cistern wall from vibrating * d) provide a horizontal connection to the cistern. ## 40. Which one of the following describes best practice when fitting a replacement cold water storage cistern to an indirect system? * a) Outlet connections from the cistern must be made at low level (preferably bottom entry) to avoid contamination. * b) The minimum capacity for a cold water storage cistern supplying an indirect system to a dwelling must be 1000 litres. * c) A float operated valve installed in a cold water storage cistern must always be located opposite to the warning pipe. * d) A service valve to a distributing pipe must only be fitted when supplying a thermostatic mixing valve to a shower. ## 41. Certain types of approved float valve may be fitted with a flexible type of silencer tube, in order to * a) reduce the amount of system noise from the float valve when the cistern is filling * b) help the environment by reducing the amount of material used during manufacture * c) prevent backflow of water and subsequent contamination of the water supply * d) avoid disturbing the sediment at the bottom of the cistern due to the velocity of the Water. ## 42. Which one of the following types of fitting would usually be provided on the cold feed pipe to a hot water storage vessel in a domestic dwelling? * a) Fullway gate valve. * b) Screwdown stop valve. * c) Spherical plug valve. * d) Lockshield gate valve. ## 43. To help prevent the risk of water stagnation in a linked cold water storage cistern arrangement * a) the level of the water in the cistern should be at least 1 m above the highest outlet * b) the pipework arrangement must ensure equal draw-off from each linked cistern * c) distributing pipes must be a minimum of 28 mm in order to improve flow rates * d) a disinfecting agent should be added to the cisterns when filling the system. ## 44. Prior to carrying out any maintenance work on an electric instantaneous hot water heater, the plumber should * a) disconnect the supply pipe near to the appliance and cap it off * b) contact the water undertaker to isolate the section of the water main * c) disconnect the power supply cable to the water heater at the consumer unit * d) isolate the appliance at the consumer unit, remove the fuse and keep it safe. ## 45. When working on an existing system, temporary earth continuity bonding should be used when removing * a) a spurred fused outlet * b) a section of copper pipe * c) an electrical appliance * d) a section of polythene pipe.