Summary

This document provides training on devices and networks, specifically for EocStruxure™ Power Monitoring Expert Digital Power Global Training. It covers topics such as network performance, ION Setup, meter configuration and time synchronization.

Full Transcript

Devices and Networks EocStruxureTM Power Monitoring Expert Digital Power Global Training Confidential Property of Schneider Electric Internal Chapter Objective: By the end of this chapter, you will be able to understand: 1. Download and install the...

Devices and Networks EocStruxureTM Power Monitoring Expert Digital Power Global Training Confidential Property of Schneider Electric Internal Chapter Objective: By the end of this chapter, you will be able to understand: 1. Download and install the latest version of the ION Setup configuration utility 2. Build a network of devices in ION Setup for configuration 3. Confirm the basic metering operation of ION and Modbus devices Internal Agenda 01 02 03 04 Network Performance ION Setup Meter Configuration Time Synchronization 05 Key Points to Remember Network Performance Optimize System Performance Ethernet networks will provide a better performance than serial networks Communications between the software and the devices consists of: On demand, real-time data requests, for example for Diagrams or Dashboards displays. Periodic polling and uploading of data logs, events, and waveform records. Confidential Property of Schneider Electric | Page 5 Internal Optimize the on demand and background polling performance Real-time data polling periods should be set to Setup the devices to only log those meet the user needs. Do not poll with high measurements that are needed to meet the user speed when it is not needed. needs. Disable devices that are not presently Schedule the log uploads to occur at times when commissioned or functional. the system usage is low, for example during night time or off hours. Connect high-end devices with power quality monitoring features, such as the ION9000, Use the Daisy Chain Calculator tool to directly through Ethernet, not serial. determine the maximum number of devices in a serial loop for your system. Note: The ION9000T with high speed transient capture, will NOT upload high speed transient waveform data to the software if it is connected through a serial connection. Confidential Property of Schneider Electric | Page 6 Internal ION Setup Meter configuration and verification utility ION Setup v3.0 A free, user-friendly configuration tool that for setting up and verifying settings on PowerLogic meters and other devices. It supports: Ethernet devices Serial devices, via Ethernet Gateways Serial devices, directly Serial devices, via Modem ION Setup showing a network of devices to configure Confidential Property of Schneider Electric | Page 8 Internal ION Setup resources ION Setup is available to download from the Schneider Electric website, www.schneider- electric.com Main link to all ION Setup related information https://www.schneider-electric.com/en/download/document/ION_Setup_Latest_Release/ Confidential Property of Schneider Electric | Page 9 Internal Exercise – 5 Install ION Setup v3.x Duration: 10 mins Page: 8 of Student Workbook Link: https://www.schneider-electric.com/en/download/document/ION_Setup_Latest_Release/ Confidential Property of Schneider Electric | Page 10 Your first installation (Network Builder Wizard) ION Setup v3.0 The Network Builder Wizard opens the first time ION Setup is run. This wizard allows the user to quickly and easily set up and configure their first system made up of sites, groups, and devices. See ION Setup Help > Starting your first installation (Network Builder wizard) to learn about using the wizard. The next time you start ION Setup, the sites and devices you have added will be available in Network Mode where you can add, remove, or configure sites and devices to continue building your network. Confidential Property of Schneider Electric | Page 11 Internal Add a Site, Modbus Device and an Ethernet Device Supporting to Exercise – 6 Group.Name Type of Address Address Address Address Group Name Device Type (Do Not Edit) comm VM 1 to 3 VM 4 to 6 VM 7 to 9 VM 10 to 12 PM5100 series Serial (5) 192.168.100.102 x x BoardA Lighting1 BoardA.Lighting1 PM5350 Serial (1) x x 192.168.100.102 BoardA HVAC1 BoardA.HVAC1 ION 9000 Ethernet 192.168.100.112 192.168.100.113 192.168.100.116 192.168.100.117 Confidential Property of Schneider Electric | Page 12 Internal Exercise – 6 Define a Network of Devices in ION Setup Duration: 15 mins Page: 9 of Student Workbook Resource: Pre-Startup Name Verification.xlsx Confidential Property of Schneider Electric | Page 13 Meter Configuration Meter Configuration A minimum set of parameters must be configured in all PowerLogic devices to ensure proper operation. Additional parameters may be configured, as required by the customer. Basic Metering Communication Clock System type (delta or wye) Communication Internal clocks ensure accurate timestamps for onboard alarms Current transformer (CT) and Serial or Ethernet ports and/or onboard data logs. potential transformer (PT) ratios IP address, subnet, gateway Configure to synchronize with the Modbus ID, baud rate Power Monitoring Expert server. Confidential Property of Schneider Electric | Page 15 Internal Basic Configuration Can use front panel or ION Setup. PM8000 front panel ION Setup screens Limited to basic settings and Setup Menu functions, like: Metering (system type, CT, PT) Communications Display Clock Alarms Language Security Confidential Property of Schneider Electric | Page 16 Internal Advanced Configuration Must be completed using Setup Screens Setup Assistant ION Setup. Parameters (for Modbus devices) (for ION devices) could include: Data recording and memory allocation Power quality detection Input metering for WAGES Digital / analog output settings Custom front panel displays Confidential Property of Schneider Electric | Page 17 Internal Meter Verification and Phasor Viewer in ION Setup Verify the proper metering operation of the Verify the phasor diagram of the device and help device and help to answer questions, like: to answer questions like: Are the measurements close to the expected Are the PTs and CTs wired correctly? value? Confidential Property of Schneider Electric | Page 18 Internal Exercise – 7 Verify configuration of an ION Device in ION Setup Duration: 15 mins Page: 14 of Student Workbook Confidential Property of Schneider Electric | Page 19 Exercise – 8 Verify configuration of a Modbus Device in ION Setup Duration: 10 mins Page: 18 of Student Workbook Confidential Property of Schneider Electric | Page 20 Time Synchronization Time Synchronization Devices must be time synchronized to maintain accurate time in PME  Depending on the synchronization mechanism, different levels of time accuracy can be achieved.  PME has the ability to synchronize devices to the PME server computer clock.  This can be done over Serial Networks and Ethernet Networks. Confidential Property of Schneider Electric | Page 22 Internal Time Synchronization Configuration Choose a single time synchronization source per device Full device time synchronization requires two steps: NTP PME Configure a time source to send time synchronizations Server Server Configure the devices to receive time synchronizations Example Both a Power Monitoring Expert server and NTP server are sending time synchronizations across the same local network. Because they are both valid time synchronization sources for a PowerLogic ION9000, the ION9000 must be configured to receive the time synchs from just one of the sources (for example, the Power Monitoring Expert server). Confidential Property of Schneider Electric | Page 23 Internal Time Synchronization Sources Systems where time synchronization is Systems that Require High Accuracy (± 1 ms) Not Critical (± 1 s): time synchronization for power quality monitoring, sequence of events recording Power Monitoring Expert server (SER), revenue billing or system stability DNP monitoring, use: NTP PTP DLMS GPS IRIG-B Use a protocol that is common for all devices to avoid multiple time synchronization signals in the network. Confidential Property of Schneider Electric | Page 24 Internal Enable time synchronization on an ION device 1. Connect to the device using ION Setup. On the Timezone tab for Clock, change entry for the CL1 Time Sync Source. You can also do this on the meter front panel. Confidential Property of Schneider Electric | Page 25 Internal Enable time synchronization on an ION device 2. In Management Console: For an Ethernet device, set the Time Synch Ethernet Enabled to Yes in the Ethernet Device Configuration. For a serial device, set the Time Synch ION Enabled to Yes in the Ethernet Gateway. Confidential Property of Schneider Electric | Page 26 Internal RECAP Internal Key Points to Remember PowerLogic ION Setup is a configuration utility The minimum PowerLogic device setup that is recommended for device configuration. includes: Create a network of devices for initial and future CT and PT ratios programmed and the System Type device configuration. (that is, delta or wye) Configure PowerLogic ION devices using the Setup Communication settings Assistant. Clock and time synchronization (for example, use the Configure PowerLogic Modbus devices using Setup Power Monitoring Expert server) for devices with Screens. onboard alarms and data logs. Confidential Property of Schneider Electric | Page 28 Internal © 2021 Schneider Electric. All Rights Reserved. Schneider Electric and Life Is On Schneider Electric are trademarks and the property of Schneider Electric, its subsidiaries, and affiliated companies. Internal

Use Quizgecko on...
Browser
Browser