What is the primary factor that controls x-ray quantity?

  • Milliamperage-second (mAs) (correct)
  • Kilovoltage (kVp)
  • Distance (d)
  • Filtration
  • If the mA is doubled, what happens to the mAs?

  • The mAs remains the same
  • The mAs is doubled (correct)
  • The mAs is quadrupled
  • The mAs is halved
  • Which of the following factors affects x-ray quality?

  • X-ray quantity
  • Distance (d)
  • Milliamperage-second (mAs)
  • Kilovoltage (kVp) and filtration (correct)
  • What is the half-value layer (HVL) a measure of?

    <p>X-ray quality</p> Signup and view all the answers

    What is the unit used to measure x-ray quantity or exposure?

    <p>Roentgen (R)</p> Signup and view all the answers

    What effect does a 15% increase in kVp have on exposure, according to the 15% rule?

    <p>Causes a doubling in exposure</p> Signup and view all the answers

    When changing kVp, what effect does it have on the interaction and absorption of the x-ray beam with anatomic tissue?

    <p>Reduces interaction and absorption</p> Signup and view all the answers

    What term is used to describe the distance an x-ray beam travels in matter?

    <p>Penetrability</p> Signup and view all the answers

    What is the effect of increasing the Source-to-Image Distance (SID) on x-ray beam intensity?

    <p>Decreases x-ray beam intensity proportionally</p> Signup and view all the answers

    According to the Reciprocity Law, what remains unchanged as long as the total exposure remains the same?

    <p>Density</p> Signup and view all the answers

    What happens to the x-ray beam intensity when the distance from the source is increased from 40cm to 72cm, according to the Inverse Square Law?

    <p>It decreases by a factor of 2</p> Signup and view all the answers

    Which factor would lead to an increase in the number of transmitted rays on the Image Receptor (IR)?

    <p>$\text{Increasing kVp}$</p> Signup and view all the answers

    Which of the following statements about the relationship between kVp and radiographic density is correct?

    <p>kVp has a tremendous impact on the radiographic density and is the controller of differences in radiographic densities (contrast)</p> Signup and view all the answers

    What is the primary factor that controls the quality and quantity of an x-ray beam?

    <p>kVp (kilovoltage peak)</p> Signup and view all the answers

    How does increasing the kVp affect the quantity of x-ray photons produced?

    <p>The quantity of x-ray photons increases approximately proportional to the square of the ratio of the change in kVp</p> Signup and view all the answers

    What is the primary factor that determines the degree of blackening (density) on a radiographic film?

    <p>The deposit of black metallic silver on the film emulsion</p> Signup and view all the answers

    What is the primary factor that determines the contrast in a radiographic image?

    <p>The kVp setting</p> Signup and view all the answers

    Which of the following statements about the relationship between x-ray beam quality and kVp is correct?

    <p>Higher kVp results in a higher quality x-ray beam with greater penetrating ability</p> Signup and view all the answers

    More Quizzes Like This

    X-Ray Radiation Quantity and Quality Quiz
    5 questions
    X-ray Basics Flashcards
    29 questions

    X-ray Basics Flashcards

    LuminousGadolinium avatar
    LuminousGadolinium
    X-Ray Circuit Basics
    60 questions

    X-Ray Circuit Basics

    StylishPeach4517 avatar
    StylishPeach4517
    Use Quizgecko on...
    Browser
    Browser