What is observed after the burner starts, indicating the boiler is heating properly?

  • The “CALL FOR HEAT” light comes on (correct)
  • The fuel gas feed valve closes
  • The “ALARM” light turns off
  • The water level increases

The boiler can start if the level is < 50% and the pumps will turn on to fill the boiler to greater than 50%.

True (A)

Where should the condensate be purged into when opening the HS-305 valve?

  • The condensate tank
  • The utility header
  • The sewer (correct)
  • The boiler feedwater system

If the water level in the boiler is below the sight glass, what happens?

<p>The boiler will be prevented from starting, but the pumps will start to fill the boiler (A)</p> Signup and view all the answers

What should be done once “dry” steam is observed from the bleeders?

<p>Slowly close the three bleeder valves to allow the steam pressure to increase (A)</p> Signup and view all the answers

Basic required PPE includes glasses, hardhat, and gloves.

<p>True (A)</p> Signup and view all the answers

What is the first step when starting up the boiler after a normal shutdown?

<p>Announce that the steam purge valves are about to be opened (B)</p> Signup and view all the answers

What should be done after the boiler control switch is turned on?

<p>Wait for the “FUEL ON” light (C)</p> Signup and view all the answers

The procedure outlines the steps for starting up the F-300 boiler after a normal shutdown.

<p>True (A)</p> Signup and view all the answers

What should be done after opening the HS-305 valve?

<p>Open the y-strainer bleeder valve near stanchion 2B (C)</p> Signup and view all the answers

Which valve is opened for the fuel gas feed to the boiler?

<p>HS-302 (C)</p> Signup and view all the answers

What happens when the boiler is in “hot standby”?

<p>The bleeder valves are fully closed (D)</p> Signup and view all the answers

Before opening the steam purge valves, the operator should make an announcement to all personnel to prevent burns from hot condensate and steam.

<p>True (A)</p> Signup and view all the answers

Opening the HS-305 valve allows steam to be purged from the utility header into the sewer.

<p>False (B)</p> Signup and view all the answers

Who should be physically present to confirm the proper boiler line-up and startup?

<p>The course instructor (A)</p> Signup and view all the answers

Before starting up the boiler, the instructor must be physically present to confirm proper line-up and start-up.

<p>True (A)</p> Signup and view all the answers

What action should be taken if the display screen shows an error message?

<p>Refer to the troubleshooting instructions for the error (D)</p> Signup and view all the answers

If the level % is < 50%, the boiler cannot start but the pumps will start to fill the boiler.

<p>False (B)</p> Signup and view all the answers

If the water level is greater than 70%, what action should be taken?

<p>Refer to the boiler blowdown procedure (D)</p> Signup and view all the answers

What should be checked on the boiler control panel before starting up the boiler?

<p>The “POWER ON” light should be green (B)</p> Signup and view all the answers

To line up the boiler feed water, the operator must open the two valves on the deaerator water feed.

<p>True (A)</p> Signup and view all the answers

When observing “dry” steam from the three bleeders, the steam pressure should decrease slowly.

<p>False (B)</p> Signup and view all the answers

What must be verified before opening the boiler feed water inlet valve?

<p>The pump discharge valves are open (D)</p> Signup and view all the answers

The boiler is in “hot standby” after closing HS-305, y-strainer bleeder valve, and bleeder valve on utility station #1.

<p>True (A)</p> Signup and view all the answers

Which valve should be opened to start the fuel gas feed to the boiler?

<p>HS-302 (C)</p> Signup and view all the answers

Flashcards

Capital of France (example flashcard)

Paris

More Like This

Sample Quiz
20 questions

Sample Quiz

EffectiveTopology2534 avatar
EffectiveTopology2534
Sample Quiz
20 questions

Sample Quiz

EffectiveTopology2534 avatar
EffectiveTopology2534
Sample Quiz
20 questions

Sample Quiz

EffectiveTopology2534 avatar
EffectiveTopology2534
Sample Quiz
70 questions

Sample Quiz

RealisticTaylor avatar
RealisticTaylor
Use Quizgecko on...
Browser
Browser