A380 Free Fall System and GDO
15 Questions
9 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

Free Fall Control Module (FFCM) Channel A is powered by?

  • 28 VDC Bus 2
  • 28 VDC Bus 1 (correct)
  • DC Essential Bus
  • DC Emergency Bus

Free Fall Control Module (FFCM) Channel B is powered by?

  • 28 VDC Bus 2
  • 28 VDC Bus 1
  • DC Essential Bus (correct)
  • DC Emergency Bus

Ground Door Opening System (GDO) interfaces with what FFCM Channel?

  • Channel A
  • Channel B (correct)
  • Channel A and B
  • uses NUA for opening

How many Cut-Out Valves and Vent Valves involve in Free Fall?

<p>3 cut-out valves, one for each landing gear group, Five vent valves, one for each landing gear (A)</p> Signup and view all the answers

Free Fall is a what type of system?

<p>Timer system (A)</p> Signup and view all the answers

1st Step in 6 steps Free Fall

<p>From 0 to 7 sec., the cut-out valve actuators are energized to isolate the hydraulic supply from each Landing Gear hydraulic circuit. (D)</p> Signup and view all the answers

2nd Step in 6 steps Free Fall

<p>From 7 to 14 sec., the Vent Valve actuators are energized. This causes the Vent Valve for each Landing Gear bay to open and there is free flow between the extend/retract ports of the Gear Actuator and the open/close ports of the Door Actuators. This will let the gears and doors fall by gravity when they are released. (A)</p> Signup and view all the answers

3rd Step in 6 steps Free Fall

<p>From 14 to23.5 sec., the Emergency Unlock Actuators are energized to open the NLG and WLG Door Uplocks and these Doors can free fall (B)</p> Signup and view all the answers

4th Step in 6 steps Free Fall

<p>From 23.5 to 44 sec., the Emergency Unlock Actuators of NLG and WLG Gear Uplocks are energized, and these Gears can free fall. (C)</p> Signup and view all the answers

5th Step in 6 steps Free Fall

<p>From 44 to 53.5 sec., the BLG Inner/Outer Door Emergency Unlock Actuators are energized to open the BLG Doors. (A)</p> Signup and view all the answers

Last Step in 6 steps Free Fall

<p>From 53.5 to 63.5 sec., BLG Gear Emergency Unlock Actuators are energized to release the BLG. (D)</p> Signup and view all the answers

What position of Landing Gear if the independent L/G indication panel has no light?

<p>L/G Up and Locked (B)</p> Signup and view all the answers

What position of Landing Gear if the independent L/G indication panel is RED UnlocKeD?

<p>L/G neither locked up nor locked down, which means discrepancy between L/G lever position and the related L/G status, (C)</p> Signup and view all the answers

When all the Landing Gears are downlocked, the status of the L/G is also displayed on what part of PFD?

<p>Left - Lower (C)</p> Signup and view all the answers

This position of Door Bypass Valve Actuator allows restricted flow of fluid and the door slowly close.

<p>Intermediate (A)</p> Signup and view all the answers