Podcast
Questions and Answers
Which statement about RAID 2.0+ is incorrect?
Which statement about RAID 2.0+ is incorrect?
- Offers data recovery speeds 20 times faster than traditional RAID
- Utilizes a one-to-many rapid refactoring mode (correct)
- Involves all hard disks in the storage pool during reconstruction
- Minimizes business impact during the reconstruction phase
A customer requires a disaster recovery network that ensures business continuity and uninterrupted service during natural disasters. Which network design is the MOST suitable?
A customer requires a disaster recovery network that ensures business continuity and uninterrupted service during natural disasters. Which network design is the MOST suitable?
- One local data center and a remote data center forming a dual-disaster recovery network.
- Two data centers in the same city operating in active-active mode, plus another data center in a different location using asynchronous replication. (correct)
- Two data centers in the same city using synchronous replication, plus another data center in a different location using asynchronous replication.
- Two data centers in the same city forming a dual-active disaster recovery network.
Which of the following statements about SmartMatrix is FALSE?
Which of the following statements about SmartMatrix is FALSE?
- A single system can expand to virtually unlimited controllers. (correct)
- It is implemented based on the front-end shared card.
- It enables full interconnection of the back-end disk enclosure and 8 controllers.
- It incorporates both Scale-Up and Scale-Out advantages.
Which is NOT considered a basic component of a Storage Area Network (SAN) architecture?
Which is NOT considered a basic component of a Storage Area Network (SAN) architecture?
What is a key disadvantage of traditional RAID compared to RAID 2.0+ regarding the data recovery process?
What is a key disadvantage of traditional RAID compared to RAID 2.0+ regarding the data recovery process?
When determining storage backup capacity, which factor is LEAST relevant?
When determining storage backup capacity, which factor is LEAST relevant?
Which resource CANNOT be managed using SmartQoS?
Which resource CANNOT be managed using SmartQoS?
Which of the following statements about data compression is FALSE?
Which of the following statements about data compression is FALSE?
What is the minimum allocation granularity of storage space within a Thin LUN, according to the RAID 2.0+ standard?
What is the minimum allocation granularity of storage space within a Thin LUN, according to the RAID 2.0+ standard?
Which statement accurately compares serial and parallel transmission methods?
Which statement accurately compares serial and parallel transmission methods?
Regarding full controller interconnection in SmartMatrix architecture, which statement is INCORRECT?
Regarding full controller interconnection in SmartMatrix architecture, which statement is INCORRECT?
Which is NOT a feature of Huawei's hybrid flash storage?
Which is NOT a feature of Huawei's hybrid flash storage?
Considering a scenario with ten 2TB hard disks, which RAID level offers the POOREST hard disk utilization?
Considering a scenario with ten 2TB hard disks, which RAID level offers the POOREST hard disk utilization?
To facilitate rapid on-site installation and deployment of a FusionCube system, which system installation tool is MOST appropriate?
To facilitate rapid on-site installation and deployment of a FusionCube system, which system installation tool is MOST appropriate?
Which feature enables a LUN to simultaneously maintain two identical physical copies?
Which feature enables a LUN to simultaneously maintain two identical physical copies?
Flashcards
RAID 2.0+ Reconstruction
RAID 2.0+ Reconstruction
In RAID 2.0+, all hard drives participate in data reconstruction.
Disaster Recovery Network
Disaster Recovery Network
A network design that involves setting up two data centers in the same city for active-active operation and another in a different location for asynchronous replication.
SAN basic component
SAN basic component
A SAN architecture does not include routers as a basic component. Servers, backend storage and switches are needed.
Chunk Grain
Chunk Grain
Signup and view all the flashcards
Storage backup planning pitfall
Storage backup planning pitfall
Signup and view all the flashcards
Serial Communication
Serial Communication
Signup and view all the flashcards
RAID 2.0+ Advantage
RAID 2.0+ Advantage
Signup and view all the flashcards
RAID1 Disk Utilization
RAID1 Disk Utilization
Signup and view all the flashcards
HyperMirror Function
HyperMirror Function
Signup and view all the flashcards
OceanStor BCmanager
OceanStor BCmanager
Signup and view all the flashcards
Popular SAN Protocol
Popular SAN Protocol
Signup and view all the flashcards
Cascading Snapshots
Cascading Snapshots
Signup and view all the flashcards
Capacity to slave lun
Capacity to slave lun
Signup and view all the flashcards
Object of Protection for HyperLock Feature
Object of Protection for HyperLock Feature
Signup and view all the flashcards
Volatile Storage
Volatile Storage
Signup and view all the flashcards
Study Notes
- Here are study notes on the provided questions and answers
RAID 2.0+
- In RAID 2.0+, all hard disks in the storage pool participate in the reconstruction process
- RAID 2.0+ greatly reduces the impact on business operations during reconstruction
- RAID 2.0+ data recovery speed is 20 times faster than traditional RAID
Disaster Recovery Network Design
- To provide the best business continuity and maintain services during natural disasters, two data centers should be set up in the same city for active-active operation
- There should be another data center in a different location for asynchronous remote replication
SmartMatrix Architecture
- SmartMatrix combines the advantages of Scale-Up and Scale-Out
- SmartMatrix is implemented based on the front-end shared card
- SmartMatrix allows full interconnection of the back-end disk enclosure and 8 controllers
SAN Architecture
- Basic components of SAN architecture include:
- Server
- Backend storage system
- Switch
- A router is not a basic component of SAN architecture
Traditional RAID vs RAID 2.0
- A shortcoming of traditional RAID compared to RAID 2.0 is slow reconstruction speed
Storage Backup Capacity Planning
- Factors to consider when planning storage backup capacity
- Data retention period
- Total amount of data
- Deduplication rate
- Backup network is not a factor to be considered
SmartQoS
- Resources that can be controlled by SmartQoS
- LUN
- LUN group
- Host
- Host Groups cannot be controlled
Data Compression Characteristics
- Data compression reduces the storage space occupied by data
- Data compression extends the life of SSDs
- Data compression may result in loss of some data information
RAID 2.0+ Technology
- The minimum allocation granularity of storage space in Thin LUN mode is Grain
Serial Transmission
- Serial Transmission is fast, costly and suitable for long-distance transmission.
SmartMatrix Architecture Controllers
- Controllers in a single control box are fully interconnected through the passive backplane of the box
- In a storage system expanded by Scale-Out, there are direct links between controllers
- Controllers in a single control box are fully interconnected through external switches
Huawei Hybrid Flash Storage Features
- Huawei's hybrid flash storage supports SCSI and FC protocols
- Huawei's hybrid flash storage supports NFS and CIFS protocols
- Huawei's hybrid flash storage supports SAN and NAS integration
RAID 2.0 Shortcomings
- Traditional RAID's slow reconstruction speed is a shortcoming compared to RAID 2.0
RAID Technologies
- RAID1 technology has the lowest hard disk utilization when using 10 2TB hard disks
FusionCube System Installation
- FusionCube Builder is a system installation tool for rapid on-site installation and deployment of the FusionCube system
LUN
- HyperMirror feature enables a LUN to generate two physical copies at the same time
Huawei Disaster Recovery
- OceanStor BCManager achieves unified, intelligent, and simplified disaster recovery scheduling, operation, and maintenance management for Huawei's dedicated backup storage
Active-Active Disaster Recovery
- GSLB (site load balancing) is used in active-active disaster recovery to allocate traffic between servers in different regions, ensuring optimal server-customer proximity and access quality
SAN Networking
- iSCSI is a commonly used protocol in SAN networking
Snapshot
- Cascading snapshots refer to a snapshot of a snapshot
Huawei OceanStor 100D Series Storage
- Huawei OceanStor 100D series storage provides various storage services including:
- Object Storage
- Block storage
- File storage
- SDRS is not a service that is provided
HyperLock
- A File System is the object of protection of the HyperLock feature
Disaster Recovery System
- The capacity of the slave LUN should be the same as that of the master LUN when designing a primary-backup disaster recovery system
RachatLinux7
- To repair a file system error on a RachatLinux7 system, use the root user to perform fsck repair on the device while the file system is mounted
DeviceManager
- DeviceManager can collect information about:
- System log
- Operation log
- Disk log
- DeviceManager cannot collect Storage Content
Huawei all-flash storage system
- DeviceManager is Huawei's graphical management interface to query, set up, manage, and maintain all-flash storage systems
Homogeneous Migration Solution
- The operation process of the homogenous migration solution does not include: Upgrade the source storage version to V300R006
Huawei all-flash storage software
- Huawei's all-flash storage system software adopts the Symmetric Active-Active (wrong) architecture
Disk Sector
- A sector is the smallest storage unit in a hard disk
- The normal default size of a disk sector is 512Bytes
Storage Media
- DRAM storage media is volatile where as NAND Flash, PCRAM and MRAM are non-volatile
PCIe Versions
- The current versions of PCIe are 1.0, 2.0, 3.0 and 4.0
Data Deduplication
- Advantages of deduplication and compression technology
- Reduce procurement costs
- Ensure the performance priority of key businesses
- Reduce storage space
SAS Disk Enclosure
- features of 2U SAS disk enclosure Scale-Up
- The number of cascaded disk enclosures cannot exceed the maximum cascade depth of the system
- A-level cascade board connects to A controller, B-level cascade board connects to B controller
- The downstream port (EXP) of the upper disk enclosure in the same loop is connected to the upstream port (PRI) of the lower disk enclosure.
Huawei all-flash storage products
- features of the indicator lights
-The alarm indicator on the controller box turns amber, indicating that a warning has occurred in the controller box.
- The blue indicator light on the controller subrack is on, indicating that the controller subrack is being positioned.
RAID10 Descriptions
- RAID 10 combines mirroring and striping where the writes are done faster in parallel between sub-groups
- Sub groups are written in mirroring and need an even number of hard disks to function
IB Network Hierarchy
- The following levels are included in the IB network hierarchy and consist of
- Transport layer
- Network Layer
- Application layer
- Physical layer
- Link Layer
SmartVirtualization
- Uses multipath software to connect heterogeneous arrays in a multipath redundant manner
- When the local storage system uses LUNs in a heterogeneous storage system, it does not occupy the local storage system's space
- External LUNs can set up value-added functions for them, such as remote replication, snapshots, etc.
Huawei Storage Architecture
- Huawei storage supports BCD (Multiple Choice) relating to fully interconnected architecture
Routine Maintenance on Storage Devices
- Routine Maintenance on storage devices can:
- Change the modified user level to admin
- The operation performed is change
Huawei Storage Equipment
- Huawei storage equipment can support disks with SAS interface and other types such as NL SAS and SSD hard disks
Huawei Hybrid Flash Storage
- A company plans to optimize the performance of a Huawei hybrid flash storage when certain single IO sized are used
- Sequential read IO accounts for 90%
- The average utilization rate of front-end bandwidth is 90%
- Host application is a database
Performance Tuning Measures
- Performance can be increased
- Increase front-end service bandwidth
- SmartCache feature
Business needs
- The business needs to provide block services and file services and to support AD
- They should be on the same network
CIFS
- Authentication methods can include NILMKberos
- Multiple versions exist
Storage System
- Storage engineers designed high I/O characteristics
SAS Disk Enclosures
- Scale-up networking methods that can be used by Huawei SAS disk enclosures include
- Forward connection
- Reverse connection networking
- Dual-plane networking
- Symmetrical networking
Huawei's distributed storage
- Multiple Active NameNodes provide metadata services, and data is consistent across multiple nodes
- Avoid metadata service interruption caused by HDFS Name node switching
SCM Media
- SCM Media can be
- PCRAM
- ReRAM
- MRAM
Huawei OceanStor all-flash storage devices
- Use DeviceManager to create multiple LUNs at one time
- When creating a LUN using DeviceManager, you can select the application type corresponding to the LUN and can create thick LUNS
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.