What is required for the use of a Self-Contained Breathing Apparatus (SCBA) in an IDLH environment?

  • Members should wear any headgear for warmth.
  • No inspection of the SCBA is required.
  • The face piece must be off to ensure comfort.
  • Air must be breathed from SCBA with the PASS device activated. (correct)
  • Which statement about wearing eyewear with an SCBA is true?

  • Eyeglass straps can be worn under the face piece.
  • Hard contact lenses may be worn as they do not affect the seal.
  • Soft contact lenses are acceptable for extended periods. (correct)
  • Members must wear glasses with no special fittings.
  • What is the responsibility of the company officer regarding SCBA use?

  • To guarantee the use of breathing apparatus when necessary. (correct)
  • To allow any member to operate with an SCBA without training.
  • To ensure SCBA is only used after overhaul.
  • To avoid conducting any inspections.
  • What is the maximum allowable time between inspections for SCBAs?

    <p>Weekly inspections are required according to NFPA 1852.</p> Signup and view all the answers

    What is the primary role of the Incident Commander (IC)?

    <p>To manage overall command during an emergency incident</p> Signup and view all the answers

    Which NFPA standard pertains specifically to the selection and maintenance of self-contained breathing apparatus?

    <p>NFPA 1852</p> Signup and view all the answers

    Which of the following is prohibited while using an SCBA?

    <p>Having facial hair that does not meet grooming standards.</p> Signup and view all the answers

    Who is responsible for ensuring personnel are knowledgeable about respiratory protection requirements?

    <p>District Chiefs and company officers</p> Signup and view all the answers

    What should members do if they want to wear glasses while using an SCBA?

    <p>Ensure glasses use approved fitting inside the face piece.</p> Signup and view all the answers

    What is required of employees regarding fit testing of respiratory equipment?

    <p>It must be completed annually during their birth month</p> Signup and view all the answers

    What is a requirement for the PASS device in relation to the SCBA?

    <p>It must be properly functioning before using SCBA.</p> Signup and view all the answers

    What should happen if equipment purchased is found to be defective?

    <p>It must be returned to the vendor</p> Signup and view all the answers

    Which of the following is correct regarding inspections of breathing apparatus?

    <p>The SCBA should be inspected at the start of each tour of duty.</p> Signup and view all the answers

    In assessing risks related to SCBA use, what factors are deemed significant by Spring Fire Department?

    <p>Geographic location and climactic conditions</p> Signup and view all the answers

    Which of the following standards is associated with personal alert safety systems?

    <p>NFPA 1982</p> Signup and view all the answers

    What responsibility do employees have regarding the decontamination of respiratory equipment?

    <p>They are responsible for proper decontamination and sanitization</p> Signup and view all the answers

    What is the primary responsibility of the Quartermaster division in the Spring Fire Department?

    <p>Documenting fit testing records of respirators</p> Signup and view all the answers

    Who is primarily responsible for the selection and maintenance of SCBA equipment in the Spring Fire Department?

    <p>The Deputy Chief of Support Services</p> Signup and view all the answers

    What standard governs the respiratory equipment purchased by the Spring Fire Department?

    <p>NFPA 1989</p> Signup and view all the answers

    During an emergency, how much air might a SCBA unit supply compared to the standard rating?

    <p>Significantly less than the specified time</p> Signup and view all the answers

    Which condition does NOT require the use of SCBA according to the guidelines?

    <p>Entering a fire scene without hazardous materials</p> Signup and view all the answers

    What program will the Spring Fire Department maintain to ensure effective SCBA performance?

    <p>A quality assurance program</p> Signup and view all the answers

    When must repairs or updates to SCBA comply with current standards?

    <p>At the time the repairs or updates are completed</p> Signup and view all the answers

    Who is responsible for ensuring that all policies and procedures regarding SCBA are being followed?

    <p>The Deputy Chief of Support Services</p> Signup and view all the answers

    What type of battery must be used for the PASS device?

    <p>Duracell MN 1604 or PC 1604</p> Signup and view all the answers

    What inspection item is not required before filling Breathing Air Cylinders?

    <p>Color of the cylinder</p> Signup and view all the answers

    What should be done when a SCBA has been contaminated with CBRNE materials?

    <p>Consider it contaminated beyond decontamination.</p> Signup and view all the answers

    What is the consequence of not replacing the batteries when indicated by the PASS device alarm?

    <p>Possible failure of the PASS distress alarm.</p> Signup and view all the answers

    Which of the following is a component that should be checked for damage in Breathing Air Cylinders?

    <p>Outlet thread</p> Signup and view all the answers

    When should SCBA and facemasks be cleaned and disinfected?

    <p>Whenever contaminated by smoke or fires.</p> Signup and view all the answers

    Which of the following actions is necessary before refilling breathing air cylinders?

    <p>Complete a cylinder refill log.</p> Signup and view all the answers

    What is an example of contamination that necessitates immediate decontamination procedures?

    <p>Exposure to smoky atmospheres.</p> Signup and view all the answers

    What is the primary responsibility of the Deputy Chief of Support Services?

    <p>To ensure compliance with NFPA 1989 for equipment practices</p> Signup and view all the answers

    Who is authorized to make manufacturer approved repairs on SCBA equipment?

    <p>Members from the Quartermaster Department with SCBA technician certification</p> Signup and view all the answers

    Which condition would require SCBA air cylinders to be retired?

    <p>If they are more than 15 years old</p> Signup and view all the answers

    What must be done with retired SCBA equipment?

    <p>It must be rendered incapable of operation and discarded</p> Signup and view all the answers

    What action should be taken if an SCBA unit is not maintained according to annual testing?

    <p>It must be retired from service immediately</p> Signup and view all the answers

    Which group is responsible for maintaining certifications of SCBA technicians?

    <p>The SCBA Shop Manager</p> Signup and view all the answers

    What should not be attempted when servicing SCBA equipment?

    <p>Performing repairs that exceed manufacturer guidelines</p> Signup and view all the answers

    How many NFPA edition cycles must an SCBA have been in service to be retired?

    <p>Four</p> Signup and view all the answers

    Study Notes

    Spring Fire Department SCBA Guidelines

    • Spring Fire Department will only purchase and use SCBA equipment compliant with the latest NFPA standards: 1852, 1981, 1989, and 1982.
    • Risk Assessment: The department considers the expected hazards encountered by SCBA users based on their duties, frequency of use, organizational experience, location, and climate.
    • Responsibilities:
      • District Chiefs and Company officers ensure all personnel under their command understand respiratory protection requirements.
      • All employees are responsible for awareness, following respiratory protection requirements, wearing, inspecting, decontaminating and sanitizing equipment.
      • Employees must perform annual quantitative fit testing during their birth month, coordinated with the Quartermaster's office.
      • The Quartermaster division documents the fit testing records for all respirators.
      • The Deputy Chief of Support Services, in coordination with the Quartermasters, selects, supports, issues, and maintains SCBA.
      • They also ensure breathing air quality according to NFPA 1989.
    • Quality Assurance Program: Springs Fire Department maintains a program to:
      • Ensure effective and safe performance of SCBA.
      • Confirm all policies and procedures are followed.
      • Determine the effectiveness of policies and procedures.
      • Continuously improve the department's respiratory protection program.
    • Recordkeeping: All Spring Fire Department SCBA and PASS records are maintained through PSTRAX.
    • Respiratory Equipment:
      • The department purchases only NFPA compliant respiratory equipment, adhering to the most current standard at time of purchase, repair, or update.
      • SCBA units provide 45 minutes of air supply but may provide less under emergency conditions.
      • All in-service SCBA comply with the most current edition of NFPA 1981, even those used for department operations.
      • SCBA usage is required:
        • In IDLH atmospheres.
        • In all hazardous atmospheres.
        • In areas where the atmosphere may rapidly become hazardous.
        • When instructed by any officer.
    • SCBA Required Use:
      • A member must have the face piece in place, breathing air from the SCBA, with the PASS device activated.
      • No SCBA shall be used without a functional PASS device.
      • The company officer ensures the use of breathing apparatus when appropriate.
    • SCBA Use in IDLH Environments:
      • Members must breathe air from the SCBA from the initial attack to the conclusion of overhaul.
      • Eyeglass straps or temple bars cannot pass between the face piece seal and the face.
      • Members wishing to wear glasses must have spectacles fitted inside the face face piece (with Scott hardware) to avoid interfering with the seal.
      • Soft contact lenses may be worn with long-term use. Hard contact lenses are prohibited as they can dislocate causing pain or pop out with sudden movements.
      • Head coverings that pass between the face piece seal and the face cannot be worn.
      • Members cannot operate SCBA with facial hair that does not comply with SFD.055 Uniform and Grooming guidelines.
      • The SCBA face piece straps cannot be worn over protective hoods.
      • Helmets worn with face pieces cannot interfere with the face piece or face seal.
    • Inspection: **
      • Daily Inspection**: Each employee conducts a daily inspection of the SCBA assigned to their riding position at the start of each tour of duty, including the second morning of the tour. Inspection records are kept in PSTRAX.
      • Weekly Checks: Weekly checks are performed each apparatus day.
      • Inspection After Use: SCBA is also inspected after every use on scene or in training.
      • Inspection Frequency: The period between inspections for all breathing apparatus cannot exceed one week per NFPA 1852.
      • All 6 double "A" (AA) batteries must be replaced before the respirator is used again. Only Duracell MN 1604 or PC 1604 batteries are authorized to maintain tested intrinsic safety rating of the PASS.
      • Failure to replace batteries and continued use after the low battery alarm may result in failure of the PASS device alarm during use.
    • Breathing Air Cylinder Filling:
      • Prior to filling breathing air cylinders, the following should be inspected:
        • Hydrostatic date.
        • Cylinder pressure and pressure gauge.
        • Cylinder body for cracks, dents, weakened areas, heat damage, or chemical damage.
        • Composite portions of the cylinder for cuts, gouges, loose composite materials, and absence of resin.
        • Cylinder outlet threads for damage.
        • Valve hand wheel for damage.
        • Outlet for debris.
      • A breathing air cylinder refill log is completed for each cylinder refilled, accessible on the Springs Fire Department homepage.
    • Care, Cleaning, Disinfecting and Decontamination:
      • SCBA and facemasks are exposed to the same combustion products as turnout gear and are contaminated in smoky environments.
      • Properly cleaning contaminated equipment prevents exposure to carcinogens.
      • Decontamination of all contaminated equipment must follow the guidelines referenced in SFD. 002 Cancer Reduction Initiative.
      • SCBA exposed to CBRNE materials are considered contaminated beyond the ability to be decontaminated and returned to service.
      • The Deputy Chief of Support Services ensures cascade systems are inspected, tested, maintained, and documented according to NFPA 1989.
    • Maintenance:
      • Maintenance and repairs are performed by specially trained personnel with parts designed for the equipment/respirators.
      • No attempts are made to replace components or repairs beyond manufacturer recommendations.
      • The SCBA Shop Manager/Personnel are responsible for the repair and maintenance of all equipment/respirators.
    • SCBA Technician Training:
      • With manufacturer authorization, the SCBA Manager sends quartermaster department members to the SCBA Technician Course maintaining their certifications and qualifications.
      • All Spring Fire Department SCBA Technician certifications and licenses are displayed in the Airpack Shop.
    • Quartermaster Department Member Responsibility: They are authorized, with SCBA Technician Certification, to perform manufacturer approved repairs, alterations, maintenance, and testing.
    • Retirement and Disposal:
      • SCBA air cylinders and air packs are retired if any of the following criteria is met:
        • SCBA:
          • SCBA has been in service through four (4) NFPA edition cycles.
          • SCBA is not maintained according to annual testing requirements.
          • SCBA is beyond the ability to be decontaminated.
        • SCBA Air Cylinders:
          • Cylinders are 15 years or older.
          • Cylinders are not maintained according to annual testing requirements.
          • Cylinders are beyond the ability to be decontaminated.
      • Retired SCBA and air cylinders cannot be used in training.
      • All retired equipment is made inoperable and discarded.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz covers the SCBA equipment guidelines for the Spring Fire Department, including compliance with NFPA standards, risk assessment practices, and responsibilities of personnel. Understanding these protocols is essential for ensuring safety and effective usage of respiratory protection equipment in hazardous situations.

    More Like This

    SOP 74 part deux
    55 questions

    SOP 74 part deux

    ResourcefulPointillism avatar
    ResourcefulPointillism
    SCBA Safety Regulations Quiz
    10 questions
    Use Quizgecko on...
    Browser
    Browser