Podcast
Questions and Answers
According to the provided document, what is the main objective for the removal of malfunctioning SCBA or SAR equipment?
According to the provided document, what is the main objective for the removal of malfunctioning SCBA or SAR equipment?
Under what circumstances is maintenance or repair of SCBA and SAR units permitted?
Under what circumstances is maintenance or repair of SCBA and SAR units permitted?
What is the primary purpose of the daily inspection of SCBA and SAR units?
What is the primary purpose of the daily inspection of SCBA and SAR units?
In the context of the document, what does the abbreviation 'SAR' stand for?
In the context of the document, what does the abbreviation 'SAR' stand for?
Signup and view all the answers
What is the primary source of information for inspecting SCBA and SAR units?
What is the primary source of information for inspecting SCBA and SAR units?
Signup and view all the answers
Which of the following components is specifically mentioned as part of the daily SCBA and SAR inspection?
Which of the following components is specifically mentioned as part of the daily SCBA and SAR inspection?
Signup and view all the answers
When is a replacement SCBA unit required?
When is a replacement SCBA unit required?
Signup and view all the answers
What is the document's primary purpose?
What is the document's primary purpose?
Signup and view all the answers
What should you do when the SCBA unit alarms and displays a RED X on the control module?
What should you do when the SCBA unit alarms and displays a RED X on the control module?
Signup and view all the answers
What is the purpose of the self-check that the MSA G1 SCBA performs every time it is turned on?
What is the purpose of the self-check that the MSA G1 SCBA performs every time it is turned on?
Signup and view all the answers
What should you do with the SCBA after a RED X alarm has occurred and you have completed the necessary steps?
What should you do with the SCBA after a RED X alarm has occurred and you have completed the necessary steps?
Signup and view all the answers
What is the purpose of the RFID pairing tag in the Bluetooth pairing process?
What is the purpose of the RFID pairing tag in the Bluetooth pairing process?
Signup and view all the answers
How long does the connection process between the SCBA and radio take?
How long does the connection process between the SCBA and radio take?
Signup and view all the answers
What is the location of the RFID target on the SCBA?
What is the location of the RFID target on the SCBA?
Signup and view all the answers
What happens when you turn the radio off and then back on after pairing with the SCBA?
What happens when you turn the radio off and then back on after pairing with the SCBA?
Signup and view all the answers
Why is it important to pair each radio with its corresponding SCBA?
Why is it important to pair each radio with its corresponding SCBA?
Signup and view all the answers
What should be done if a face piece is found to be functioning incorrectly?
What should be done if a face piece is found to be functioning incorrectly?
Signup and view all the answers
How frequently should on-duty personnel inspect, clean, and sanitize their face pieces?
How frequently should on-duty personnel inspect, clean, and sanitize their face pieces?
Signup and view all the answers
What is the minimum pressure that a high-pressure cylinder must maintain?
What is the minimum pressure that a high-pressure cylinder must maintain?
Signup and view all the answers
What should be included in the face piece inspection process on a daily basis?
What should be included in the face piece inspection process on a daily basis?
Signup and view all the answers
What must be done to face pieces after usage, if they are contaminated?
What must be done to face pieces after usage, if they are contaminated?
Signup and view all the answers
Which of the following is TRUE regarding the inspection of SCBA and SAR units?
Which of the following is TRUE regarding the inspection of SCBA and SAR units?
Signup and view all the answers
What is the purpose of checking the Bluetooth connectivity between SCBA and radio?
What is the purpose of checking the Bluetooth connectivity between SCBA and radio?
Signup and view all the answers
Which components should receive special attention during inspections of face pieces?
Which components should receive special attention during inspections of face pieces?
Signup and view all the answers
What should be done if the face piece is found to be damaged?
What should be done if the face piece is found to be damaged?
Signup and view all the answers
During a monthly SCBA inspection, which alarm pressure is appropriate for the low pressure alarm of a high pressure unit?
During a monthly SCBA inspection, which alarm pressure is appropriate for the low pressure alarm of a high pressure unit?
Signup and view all the answers
What aspect is NOT a part of the monthly SAR inspection process?
What aspect is NOT a part of the monthly SAR inspection process?
Signup and view all the answers
Which of the following is a specific requirement during the monthly SCBA inspection regarding the rechargeable battery?
Which of the following is a specific requirement during the monthly SCBA inspection regarding the rechargeable battery?
Signup and view all the answers
What should be inspected on the hoses during the SAR unit inspection?
What should be inspected on the hoses during the SAR unit inspection?
Signup and view all the answers
What is the purpose of placing the SAR units in operation during the inspection?
What is the purpose of placing the SAR units in operation during the inspection?
Signup and view all the answers
Why is it necessary to inspect the O ring on the high-pressure line during the SCBA inspection?
Why is it necessary to inspect the O ring on the high-pressure line during the SCBA inspection?
Signup and view all the answers
The MSA G1 SCBA unit uses a battery located where?
The MSA G1 SCBA unit uses a battery located where?
Signup and view all the answers
Study Notes
SCBA and SAR Maintenance and Inspection
- Defective or nonfunctioning SCBAs or SARs shall be removed from service and shall not be placed back in service until repaired by the SCBA Division.
- A replacement SCBA unit shall be secured from spare stock whenever possible.
- Only trained personnel or those certified by the manufacturer shall perform maintenance or repair operations on SCBAs and SARs.
Daily SCBA and SAR Inspection
- SCBA and SAR units shall be inspected for proper operation by the apparatus operator or any firefighter assigned by the Company Officer.
- Inspect the SCBA and SAR units for proper operation according to manufacture specifications, focusing on:
- Examine the harness, PASS device, and buddy breather hose for excessive wear and damage.
- Examine cylinders for excessive wear and evaluate cylinder pressure.
- Check the bypass valve, cylinder valve, and low pressure alarms.
- Ensure SCBA and radio Bluetooth are paired and functioning correctly.
Face Piece Inspection and Sanitizing
- Inspect face pieces daily according to the manufacturer's specification.
- Clean and sanitize face pieces after each use.
- On the 4th Sunday of each month, inspect, clean, and sanitize face pieces according to manufacturer's specifications.
Monthly SCBA Inspection
- On the 4th Sunday of each month, inspect SCBA units according to manufacturer's specifications, focusing on:
- Complete the daily inspection process.
- Check the operation of the low pressure alarm for correct activation pressure.
- Check the high pressure line "O" ring for presence and damage.
- Replace the rechargeable battery in the back plate.
Monthly SAR Inspection
- On the 4th Sunday of each month, inspect SAR units and Very Clear communication units according to manufacturer's specifications, focusing on:
- Complete the daily inspection process.
- Inspect hoses from the Tower fill connection and hoses from the SAR regulator.
- Place the SAR regulator in operation and check for leaks and the activation of the low pressure alarm.
- Place the SAR units in operation and check for leaks and adequate air flow from the mask-mounted regulator.
- Inspect, clean, and sanitize all SAR and face pieces according to manufacturer's specifications.
Additional Information
- The MSA G1 uses a single battery located in the back plate of the SCBA unit to operate all the electronics.
- The battery shall be changed on the Sunday the assigned vehicle is to have the Weekly Apparatus Maintenance completed or when the control module displays a low battery.
- In the event of a Red X alarm, remove the battery from the back plate, complete a department work order, and allow the SCBA to remain in service until repair can be made by the SCBA Division.
Bluetooth Pairing G1 SCBA and Radio
- Power on the G1 SCBA and Motorola Radio.
- Press and hold one of the Green buttons until the RFID icon is displayed on the control module.
- Place the radio-specific RFID pairing tag over the RFID target on the SCBA.
- Press and hold the small button on the lapel mic until the audible indicator occurs.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
Learn about the procedures for inspecting, maintaining, and repairing SCBA and SAR equipment, including who can perform these tasks and how to ensure they are in proper working order.