SCBA and SAR Maintenance and Inspection
32 Questions
0 Views

SCBA and SAR Maintenance and Inspection

Created by
@LighterElm

Questions and Answers

According to the provided document, what is the main objective for the removal of malfunctioning SCBA or SAR equipment?

  • To ensure that the units are repaired by qualified personnel, preventing potential harm to users. (correct)
  • To comply with the manufacturer's warranty and avoid any potential legal issues.
  • To ensure that all units are always available for use, even if they are not fully functional.
  • To reduce the overall number of SCBA and SAR units in service.
  • Under what circumstances is maintenance or repair of SCBA and SAR units permitted?

  • Only personnel trained by the SCBA Division or certified by the manufacturer are authorized. (correct)
  • Any qualified personnel can perform maintenance if they are familiar with the unit's manual.
  • Maintenance is only permitted during routine apparatus inspections.
  • Maintenance can be performed by any firefighter, provided they follow the manufacturer's instructions.
  • What is the primary purpose of the daily inspection of SCBA and SAR units?

  • To identify any potential issues before they can cause harm during an emergency. (correct)
  • To ensure that the units are cleaned and disinfected after each use.
  • To comply with the manufacturer's warranty requirements.
  • To check if the units are fully charged and ready for immediate use.
  • In the context of the document, what does the abbreviation 'SAR' stand for?

    <p>Search and Rescue</p> Signup and view all the answers

    What is the primary source of information for inspecting SCBA and SAR units?

    <p>The manufacturer's specifications and guidelines.</p> Signup and view all the answers

    Which of the following components is specifically mentioned as part of the daily SCBA and SAR inspection?

    <p>PASS device</p> Signup and view all the answers

    When is a replacement SCBA unit required?

    <p>Whenever a unit is found to be malfunctioning.</p> Signup and view all the answers

    What is the document's primary purpose?

    <p>To outline the maintenance and inspection procedures for SCBA and SAR units.</p> Signup and view all the answers

    What should you do when the SCBA unit alarms and displays a RED X on the control module?

    <p>Remove the battery from the back plate and complete a department work order</p> Signup and view all the answers

    What is the purpose of the self-check that the MSA G1 SCBA performs every time it is turned on?

    <p>To ensure that all components are functioning correctly</p> Signup and view all the answers

    What should you do with the SCBA after a RED X alarm has occurred and you have completed the necessary steps?

    <p>The SCBA should remain in service until the repair can be made</p> Signup and view all the answers

    What is the purpose of the RFID pairing tag in the Bluetooth pairing process?

    <p>To pair the SCBA with the corresponding radio</p> Signup and view all the answers

    How long does the connection process between the SCBA and radio take?

    <p>Up to 30 seconds</p> Signup and view all the answers

    What is the location of the RFID target on the SCBA?

    <p>Behind the waist strap on the bell side of the SCBA</p> Signup and view all the answers

    What happens when you turn the radio off and then back on after pairing with the SCBA?

    <p>You will hear an audible indicator from the radio and the blue tooth symbol will be bolded</p> Signup and view all the answers

    Why is it important to pair each radio with its corresponding SCBA?

    <p>To ensure that the correct SCBA is used with the correct radio</p> Signup and view all the answers

    What should be done if a face piece is found to be functioning incorrectly?

    <p>It should be removed from service and a replacement secured.</p> Signup and view all the answers

    How frequently should on-duty personnel inspect, clean, and sanitize their face pieces?

    <p>On the 4th Sunday of each month.</p> Signup and view all the answers

    What is the minimum pressure that a high-pressure cylinder must maintain?

    <p>4000 psi</p> Signup and view all the answers

    What should be included in the face piece inspection process on a daily basis?

    <p>Checking for the condition of the nose cup and exhalation valve.</p> Signup and view all the answers

    What must be done to face pieces after usage, if they are contaminated?

    <p>Clean and sanitize them according to specifications.</p> Signup and view all the answers

    Which of the following is TRUE regarding the inspection of SCBA and SAR units?

    <p>Cylinder valves on SAR units should be tested only.</p> Signup and view all the answers

    What is the purpose of checking the Bluetooth connectivity between SCBA and radio?

    <p>To confirm that the two devices are paired and functioning correctly.</p> Signup and view all the answers

    Which components should receive special attention during inspections of face pieces?

    <p>The condition of the nose cup, face shield, exhalation valve, and head harness straps.</p> Signup and view all the answers

    What should be done if the face piece is found to be damaged?

    <p>The unit is to be removed from service and replaced.</p> Signup and view all the answers

    During a monthly SCBA inspection, which alarm pressure is appropriate for the low pressure alarm of a high pressure unit?

    <p>Approximately 1550 psi.</p> Signup and view all the answers

    What aspect is NOT a part of the monthly SAR inspection process?

    <p>Replacing the aircraft battery used in SAR units.</p> Signup and view all the answers

    Which of the following is a specific requirement during the monthly SCBA inspection regarding the rechargeable battery?

    <p>Replace the battery in the back plate.</p> Signup and view all the answers

    What should be inspected on the hoses during the SAR unit inspection?

    <p>The hoses for any visible damage or wear.</p> Signup and view all the answers

    What is the purpose of placing the SAR units in operation during the inspection?

    <p>To check for leaks and adequate airflow.</p> Signup and view all the answers

    Why is it necessary to inspect the O ring on the high-pressure line during the SCBA inspection?

    <p>To prevent leaks and ensure safety.</p> Signup and view all the answers

    The MSA G1 SCBA unit uses a battery located where?

    <p>In the back plate.</p> Signup and view all the answers

    Study Notes

    SCBA and SAR Maintenance and Inspection

    • Defective or nonfunctioning SCBAs or SARs shall be removed from service and shall not be placed back in service until repaired by the SCBA Division.
    • A replacement SCBA unit shall be secured from spare stock whenever possible.
    • Only trained personnel or those certified by the manufacturer shall perform maintenance or repair operations on SCBAs and SARs.

    Daily SCBA and SAR Inspection

    • SCBA and SAR units shall be inspected for proper operation by the apparatus operator or any firefighter assigned by the Company Officer.
    • Inspect the SCBA and SAR units for proper operation according to manufacture specifications, focusing on:
      • Examine the harness, PASS device, and buddy breather hose for excessive wear and damage.
      • Examine cylinders for excessive wear and evaluate cylinder pressure.
      • Check the bypass valve, cylinder valve, and low pressure alarms.
      • Ensure SCBA and radio Bluetooth are paired and functioning correctly.

    Face Piece Inspection and Sanitizing

    • Inspect face pieces daily according to the manufacturer's specification.
    • Clean and sanitize face pieces after each use.
    • On the 4th Sunday of each month, inspect, clean, and sanitize face pieces according to manufacturer's specifications.

    Monthly SCBA Inspection

    • On the 4th Sunday of each month, inspect SCBA units according to manufacturer's specifications, focusing on:
      • Complete the daily inspection process.
      • Check the operation of the low pressure alarm for correct activation pressure.
      • Check the high pressure line "O" ring for presence and damage.
      • Replace the rechargeable battery in the back plate.

    Monthly SAR Inspection

    • On the 4th Sunday of each month, inspect SAR units and Very Clear communication units according to manufacturer's specifications, focusing on:
      • Complete the daily inspection process.
      • Inspect hoses from the Tower fill connection and hoses from the SAR regulator.
      • Place the SAR regulator in operation and check for leaks and the activation of the low pressure alarm.
      • Place the SAR units in operation and check for leaks and adequate air flow from the mask-mounted regulator.
      • Inspect, clean, and sanitize all SAR and face pieces according to manufacturer's specifications.

    Additional Information

    • The MSA G1 uses a single battery located in the back plate of the SCBA unit to operate all the electronics.
    • The battery shall be changed on the Sunday the assigned vehicle is to have the Weekly Apparatus Maintenance completed or when the control module displays a low battery.
    • In the event of a Red X alarm, remove the battery from the back plate, complete a department work order, and allow the SCBA to remain in service until repair can be made by the SCBA Division.

    Bluetooth Pairing G1 SCBA and Radio

    • Power on the G1 SCBA and Motorola Radio.
    • Press and hold one of the Green buttons until the RFID icon is displayed on the control module.
    • Place the radio-specific RFID pairing tag over the RFID target on the SCBA.
    • Press and hold the small button on the lapel mic until the audible indicator occurs.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Learn about the procedures for inspecting, maintaining, and repairing SCBA and SAR equipment, including who can perform these tasks and how to ensure they are in proper working order.

    More Quizzes Like This

    SCBA Inspection and Maintenance
    11 questions
    Firefighting Equipment and Procedures
    15 questions
    E-SCBA Part 4
    16 questions

    E-SCBA Part 4

    ProtectiveJackalope4164 avatar
    ProtectiveJackalope4164
    SOP 604 SCBA Use and Maintenance
    16 questions
    Use Quizgecko on...
    Browser