IECC questions from MCS
12 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

A low-sloped roof has a slope less than _____ units vertical in _____ units horizontal:

  • 3 UNITS / 12 UNITS
  • 2 UNITS / 10 UNITS
  • 2 UNITS / 12 UNITS (correct)
  • 3 UNITS / 10 UNITS
  • A Marine Climate Zone has a mean temperature of the coldest month between _____ and _____:

  • 27°F AND 65°F (correct)
  • 25°F AND 67°F
  • 30°F AND 70°F
  • 37°F AND 75°F
  • Each residence should have a programmable thermostat that includes the capability to maintain zone temperatures down to _____ or up to _____:

  • 50°F OR 80°F
  • 45°F OR 75°F
  • 55°F OR 85°F (correct)
  • 60°F OR 85°F
  • The building official shall inspect periodically existing buildings and structures, specifically, Group A-1 movie theaters at a minimum, an a _________ basis, and at a maximum, during a ________ period.

    <p>SEMI-ANNUAL + ONE YEAR</p> Signup and view all the answers

    A heating system that transfers heat to objects and surfaces within a conditioned space, primarily through infrared radiation:

    <p>RADIANT HEATING SYSTEM</p> Signup and view all the answers

    Fenestration may refer to the following product classifications if installed at a slope of less than 60 degrees from horizontal:

    <p>ALL OF THE ABOVE</p> Signup and view all the answers

    In a residence, at least _____ thermostat/thermostats shall be provided for each separate heating and cooling system:

    <p>ONE</p> Signup and view all the answers

    In residences, not less than _____% of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps:

    <p>75%</p> Signup and view all the answers

    A device, installed at the building entrance, that generates and discharges a laminar air stream intended to prevent the infiltration of external, unconditioned air into the conditioned spaces, or the loss of interior, conditioned air to the outside:

    <p>AIR CURTAIN</p> Signup and view all the answers

    The interior design temperatures used for heating and cooling load calculations shall be a maximum of _____ for heating and minimum of _____ for cooling:

    <p>72°F FOR HEATING AND 75°F FOR COOLING</p> Signup and view all the answers

    In residences, walls associated with conditioned basements shall be insulated from the top of the basement wall down to _____ feet below grade or to the basement floor, whichever is less:

    <p>10</p> Signup and view all the answers

    In a residence, supply and return ducts in attics shall be insulated to a minimum of R-# where 3 inches in diameter and greater:

    <p>R-8</p> Signup and view all the answers