Move tool center point in a straight line from start to destination programmed at destination position?
Move tool center point in a straight line from start to destination programmed at destination position?
Current, pressure, and time are the 3 main variables in resistance spot welding.
Current, pressure, and time are the 3 main variables in resistance spot welding.
True
In a PLC program, arranging two XIC instructions in a series provides an ___ logic.
In a PLC program, arranging two XIC instructions in a series provides an ___ logic.
AND
What is an EPROM (pronounced E-PROM)?
What is an EPROM (pronounced E-PROM)?
Signup and view all the answers
Is ROM volatile or non-volatile?
Is ROM volatile or non-volatile?
Signup and view all the answers
A flashing red I/O module status (OK) indicator indicates that the module has a ___ fault.
A flashing red I/O module status (OK) indicator indicates that the module has a ___ fault.
Signup and view all the answers
A single output device has failed while the remainder of the PLC system is functioning normally. The indicator light on the output module indicates that a signal is sent to the output point where the device is connected. You would now:
A single output device has failed while the remainder of the PLC system is functioning normally. The indicator light on the output module indicates that a signal is sent to the output point where the device is connected. You would now:
Signup and view all the answers
A conveyor system controlled by a PLC needs to stop when an item reaches the end. The sensor detecting the item has intermittent faults. Which of the following would best improve the system's reliability?
A conveyor system controlled by a PLC needs to stop when an item reaches the end. The sensor detecting the item has intermittent faults. Which of the following would best improve the system's reliability?
Signup and view all the answers
In a PLC network, which of the following protocols would be most suitable for real-time control data transmission?
In a PLC network, which of the following protocols would be most suitable for real-time control data transmission?
Signup and view all the answers
An example of volatile memory is?
An example of volatile memory is?
Signup and view all the answers
1 Doubleword of information = ?
1 Doubleword of information = ?
Signup and view all the answers
What is the part of the PLC called where inputs and outputs are connected?
What is the part of the PLC called where inputs and outputs are connected?
Signup and view all the answers
Where does PLC stores its program?
Where does PLC stores its program?
Signup and view all the answers
Which of the following is an example of discrete (digital) control?
Which of the following is an example of discrete (digital) control?
Signup and view all the answers
Study Notes
Robotics
-
Move Tool Center Point: Use
MoveL
to program movement in a straight line from the start to the destination. -
Negative Z Direction: Z negative direction refers to
Down
. -
Converting External Signals: Conversion of external signals to numeric is done through
Analog I/O
. -
J3, Up, Down: Refers to
Elbow Configuration
, indicating the orientation of the robot's joints. -
Digital I/O Sequence: A sequence of 16 ones and zeros is categorized as
Group I/O
. -
Jogging Robot in World -Y: Jogging the robot in this direction results in movement
Left
. -
Common Coordinate System in Robotics: The workpiece is referenced in the
Work object coordinate system
. -
Robot's Load Capacity: The maximum weight that a robot can safely handle is termed as
Payload
. -
Robot Crash Recovery First Step: The initial step should be to
Press the emergency stop on the pendant and call for recovery support
. -
Key Variables in Resistance Spot Welding: Current, pressure, and time are essential; statement is
True
. -
Position Hold While Motors are On: Position is maintained by
Brakes located inside the motors
.
PLC (Programming Logic Controller)
-
XIC Instruction in Series: Arranging two XIC instructions results in
AND
logic. - EPROM Definition: It's a programmable memory chip that can be erased and reprogrammed using ultraviolet light.
-
ROM Characteristics: ROM is classified as
Non-volatile
. -
Red I/O Module Indicator: A flashing red status indicates a
Hardware
fault. -
Single Output Device Failure: If an output device fails while others work, check
Wiring and connections
first. -
Improving Sensor Reliability in PLC: Implement a
debounce timer
to enhance system reliability with intermittent sensor faults. -
Real-Time Control Data Transmission Protocol:
Ethernet/IP
is most suitable for real-time control in a PLC network. -
Volatile Memory Example:
RAM
is classified as volatile memory. -
Doubleword Information Size: 1 double word equals
4 bytes
. -
PLC Input/Output Connection Part: This region is referred to as the
Interface
. -
PLC Program Storage: Programs are stored in
Memory
. -
Example of Discrete Control:
Turning a lamp ON or OFF
is a clear example of discrete control.
Electrical
- Overcurrent Trip in VFD: Conditions leading to an overcurrent trip could involve excessive load, short-circuits, or overheating circuits.