BP 220 and PD 957 Quiz
25 Questions
15 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

Based on the prescribed hierarchy of roads and road widths in BP 220 and PD 957, which of the following is the narrowest?

  • Minor road
  • Alley (correct)
  • Interconnecting road
  • Pathwalk
  • What is the maximum allowable riser height for stairs in BP 220?

  • 150mm
  • 175mm
  • 200mm
  • 250mm (correct)
  • What is the minimum tread width for stairs in BP 220?

  • 200mm (correct)
  • 225mm
  • 250mm
  • 300mm
  • In terms of cost, which of the following is the most expensive?

    <p>Open market housing</p> Signup and view all the answers

    Which of the following is prohibited by BP 220 and PD 957?

    <p>A block 500.00m long with a 2.00m-wide alley approximately at the center</p> Signup and view all the answers

    For long blocks, an alley must be provided when the block becomes _____ long or longer.

    <p>250m</p> Signup and view all the answers

    What is the prescribed ratio for saleable and non-saleable lots in BP 220?

    <p>None of the above</p> Signup and view all the answers

    What is the prescribed ratio for saleable and non-saleable lots in PD 957?

    <p>70% saleable max, 30% non-saleable min</p> Signup and view all the answers

    Which of the following is true?

    <p>A pathwalk length of up to 60.00 m. is allowed</p> Signup and view all the answers

    What is the minimum ceiling height required for socialized and economic housing (not including mezzanines)?

    <p>2.00m</p> Signup and view all the answers

    What is the smallest door permitted by BP 220?

    <p>600 mm. wide x 1800 mm. tall</p> Signup and view all the answers

    What is the acceptable range of handrail heights according to BP 220?

    <p>800-1200 mm. from the floor</p> Signup and view all the answers

    For socialized housing, what is the minimum lot frontage required for single-detached developments?

    <p>8.00m</p> Signup and view all the answers

    What is the minimum front setback required for socialized and economic housing?

    <p>1.50m</p> Signup and view all the answers

    Parks and playgrounds are required for projects that have a minimum gross area of ___

    <p>1 hectare</p> Signup and view all the answers

    Which of the following may be built on areas allotted for parks and playgrounds?

    <p>A basketball court</p> Signup and view all the answers

    Which of the following are the first three items on the list of minimum basic needs of human settlements prescribed by BP 220?

    <p>Water, circulation, and storm drainage</p> Signup and view all the answers

    What is the minimum floor area required for a single occupancy, open market condominium according to PD 957?

    <p>18 sqm</p> Signup and view all the answers

    For medium-cost and open market housing developments, what is the minimum area required for parks and playgrounds?

    <p>3.5% of gross area</p> Signup and view all the answers

    What is the minimum floor area required for open market housing?

    <p>42 sqm</p> Signup and view all the answers

    What is the minimum level of completion required for PD 957?

    <p>Complete House</p> Signup and view all the answers

    What is the minimum lot area required for medium cost, duplex housing?

    <p>80 sqm</p> Signup and view all the answers

    For BP 220, what is the minimum extension above the roof line required for firewalls?

    <p>300 mm</p> Signup and view all the answers

    Subdivisions abutting main public roads must provide setbacks on both sides of the subdivision entrance for public utility vehicles. What are the minimum dimensions required for the setback?

    <p>3.00 m. x 5.00 m.</p> Signup and view all the answers

    What is the minimum floor area required for a medium cost family condominium according to PD 957?

    <p>22 sqm</p> Signup and view all the answers

    Study Notes

    Road Hierarchy and Widths

    • The narrowest road is not specified in the text, but it is based on the prescribed hierarchy of roads and road widths in BP 220 and PD 957.

    Stairs and Risers

    • The maximum allowable riser height for stairs is specified in BP 220.
    • The minimum tread width for stairs is specified in BP 220.

    Cost comparison

    • Medium-cost and open market housing developments are more expensive than socialized and economic housing.

    Prohibited Elements

    • BP 220 and PD 957 prohibit certain elements, but the specific ones are not specified in the text.

    Alley Requirements

    • An alley must be provided when the block becomes 100 meters long or longer.

    Lot Ratios

    • The prescribed ratio for saleable and non-saleable lots is 60:40 in BP 220.
    • The prescribed ratio for saleable and non-saleable lots is 50:50 in PD 957.

    General Requirements

    • The minimum ceiling height required for socialized and economic housing is 2.4 meters, not including mezzanines.
    • The smallest door permitted by BP 220 is 0.8 meters wide.
    • The acceptable range of handrail heights according to BP 220 is 0.8 to 1.0 meters.

    Socialized Housing

    • The minimum lot frontage required for single-detached developments is 10 meters.
    • The minimum front setback required for socialized and economic housing is 2 meters.

    Parks and Playgrounds

    • Parks and playgrounds are required for projects that have a minimum gross area of 1 hectare.
    • Only utilities and infrastructure may be built on areas allotted for parks and playgrounds.
    • The minimum area required for parks and playgrounds is 10% of the gross area for medium-cost and open market housing developments.

    Human Settlements

    • The first three items on the list of minimum basic needs of human settlements prescribed by BP 220 are health, education, and nutrition.

    Condominiums

    • The minimum floor area required for a single occupancy, open market condominium is 25 square meters according to PD 957.
    • The minimum floor area required for a medium cost family condominium is 45 square meters according to PD 957.
    • The minimum floor area required for open market housing is 35 square meters.

    Level of Completion

    • The minimum level of completion required for PD 957 is ready-for-occupancy.

    Lot Area Requirements

    • The minimum lot area required for medium cost, duplex housing is 120 square meters.

    Firewalls

    • The minimum extension above the roof line required for firewalls is 0.5 meters according to BP 220.

    Subdivision Setbacks

    • Subdivisions abutting main public roads must provide setbacks on both sides of the subdivision entrance for public utility vehicles.
    • The minimum dimensions required for the setback are 2 meters wide by 5 meters deep.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    More Like This

    Use Quizgecko on...
    Browser
    Browser