BP 220: Socialized Housing and Economic Aspects Quiz

FamedBluebell avatar
FamedBluebell
·
·
Download

Start Quiz

Study Flashcards

18 Questions

What is the minimum height requirement for a door in a bathroom?

1.80m

How many exits are required for a building with 10 or more occupants?

2

What percentage of the floor area should be allocated for windows in bathrooms?

5%

How thick must a firewall be at a minimum?

150mm

What is the minimum headroom requirement for stairways?

2.00m

How far apart should buildings be in a 3-4 storey building scenario?

6.00m

What is the maximum length of a block as specified in BP 220?

400 meters

In socialized housing, who are the primary beneficiaries according to the text?

Underprivileged and homeless citizens

What constitutes a complete house as per the definition provided in the text?

Shell house + all windows and doors

What are the basic needs of human settlements according to the text?

Water, movement, and circulation

How is an economic housing unit different from socialized housing based on the text?

Socialized housing is for underprivileged citizens

What is the minimum required lot area for parks and playgrounds according to the text?

1 hectare

What is the minimum floor area requirement for a socioeconomic row house cluster consisting of 20 units?

18 sqm

Which road type has a minimum width of 10 meters according to the given context?

Interconnecting road

What is the maximum length allowed for a pathwalk in the subdivision plan?

60 meters

Which housing type has a minimum lot area of 54 sqm and 6x9 meters as per the given context?

Duplex

Which setback requirement is 2.0 meters as per the given context?

Rear yard

Which facility is required for projects 1 hectare or bigger, regardless of the housing category?

Multipurpose center

Study Notes

Building Design and Requirements

  • Minimum ceiling height: 2.00m
  • Mezannine ceiling height: 1.80m
  • Door heights:
    • Bathroom and mezzanine doors: 1.80m
    • All other doors: 2.00m
  • Door widths:
    • Main door: 800mm
    • Bedroom or service door: 700mm
    • Bathroom door: 600mm
  • Window requirements:
    • Regular rooms: 10% of floor area
    • Bathrooms: 5% of floor area

Stairways and Handrails

  • Riser: 250mm max.
  • Tread: 200mm min.
  • Width: 600mm min.
  • Headroom: 2.0m min.
  • Landing-to-landing: 3.6m
  • Handrail heights: 800-1200mm from floor
  • Handrails not required for stairs with less than 4 steps

Winding/Circular Stairways

  • Required tread dimension: 300mm from narrow end of stairway
  • Min tread at any point: 150mm

Ladders

  • Not allowed; instead, provide a landing every 1.8m of rise

Firewalls

  • Thickness: at least 150mm or 6 inches
  • Extensions: 300mm above roof and building edges

Property Access and Distances

  • Property must abut a public street; no pathwalks allowed
  • Distances between buildings:
    • 1-2 storey buildings: 4.00m between buildings, 1.50m between eaves
    • 3-4 storey buildings: 6.00m between buildings, 2.00m between eaves

Socialized and Economic Housing

  • Definition of socialized housing: housing units within affordability level of average and low-income earners (30% of gross family income)
  • Definition of economic housing: housing projects provided to average income families (middle class and below)

Block and Lot Requirements

  • Block: a parcel of land bounded by streets, with a maximum length of 400 meters
  • Block length with alley: 250 meters or more
  • Shell house: a habitable dwelling unit with exterior walls, floor, openings for doors and windows, plumbing fixtures, and electrical wiring
  • Complete house: a shell house with all windows and doors, and partition walls

Planning Considerations

  • Avoid areas with high risk of flood/hazards
  • Preserve trees with diameter of 200mm or greater

Parks and Playgrounds

  • Required for projects with a minimum lot area of 1 hectare
  • Minimum area: 100 sqm or 10x10 meters

Community Facilities

  • A multipurpose center is required for projects 1 hectare or bigger, whether socialized or economic

Circulation and Road Planning

  • Observe prescribed road hierarchies and minimum RROW widths within the subdivision
  • Minimum sizes of roads:
    • Interconnecting road: 10.00m
    • Major road: 8.00m
    • Collector road: 8.00m
    • Minor road: 6.5m
    • Motor court: 6.00m
    • Path walk: 3.00m
    • Alley: 2.00m

Alley vs. Pathwalk

  • Alley breaks a block and cannot be used as access to a property
  • Pathwalk provides pedestrian access to a property, may be used as property access for socialized housing only, with a maximum length of 60 meters

Setbacks and Minimum Lot Areas

  • Setbacks for PUV:
    • Front: 1.5m
    • Side yard: 1.5m
    • Rear yard: 2.0m
  • Minimum lot areas:
    • Socialized: 64 sqm (single detached), 48 sqm (duplex), 28 sqm (row house)
    • Economic: 64 sqm (single detached), 54 sqm (duplex), 36 sqm (row house)

Minimum Floor Areas and Level of Completion

  • Minimum floor areas:
    • Socialized: 18 sqm
    • Economic: 22 sqm
  • Minimum level of completion:
    • Economic housing: complete house based on submitted specifications

Test your knowledge on BP 220, which focuses on socialized housing and economic aspects such as affordability for average and low-income earners. The quiz covers topics like subdivision design, building design, single and multi-family dwellings, and basic needs of human settlements.

Make Your Own Quizzes and Flashcards

Convert your notes into interactive study material.

Get started for free

More Quizzes Like This

BP 220 and PD 957 Quiz
25 questions

BP 220 and PD 957 Quiz

WellBeingPeachTree avatar
WellBeingPeachTree
Use Quizgecko on...
Browser
Browser