RMS Volumetrics Quiz

NourishingSense avatar
NourishingSense
·
·
Download

Start Quiz

Study Flashcards

43 Questions

True or false: To open the Volumetrics dialog box, you can click the Grid under the relevant Grid model in the Data tree, and then select Volumetrics?

True

True or false: The Volumetrics dialog box has three tabs: General Tab, Calculations Tab, and Variables Tab?

False

True or false: A job can only be specified to perform volume calculations and report on the entire grid model, not a subset?

False

True or false: The use of region models in RMS is not explained in the Working with Regions page?

False

True or false: If you click the Save button in the Volumetrics dialog box, it allows you to generate multiple realizations of the results?

True

True or false: RMS calculates the volumes and displays a progress indicator pop up box when running the Volumetrics job for the current project realization?

True

True or false: If you requested a report table and the specified table object already exists but was generated using a different job specification, a warning message is displayed?

True

Map increment option allows users to adjust grid resolution for output maps, with a larger value providing more accurate maps but slower calculations.

False

Fluid contact data from a region attribute table cannot be used in Volumetrics if defined with a template based on standard contacts.

False

Variables used as input to volume calculations can only be specified through constant values.

False

Users cannot specify variables by selecting a variable class, specific variable, and subsets for which different variable values are given.

False

Variable types include oil, gas, and formation variables, each with specific variables and unit measures, defined through the Unit Set Selector in the Tools menu.

True

In the Report file tab, users can only specify the output as a Report file, and not a Report table data object.

False

Associated gas and liquid units in the Report file and table are linked to the units set for STOIIP and GIIP respectively, which are not specified in the Unit Set Selector dialog box accessed from the RMS menu bar under Tools.

False

Maps cannot be output to specific folders in the Data tree including Model QC, General 2D data, Clipboard, and Zones.

False

Input variables for select volumes are entered in the Variables tab, depending on the options selected in the Calculations tab.

True

The Variables tab lists the formulas to be used for selected calculations, with options independent of the input and calculations chosen in previous tabs.

False

Users cannot specify variables by selecting a variable class, specific variable, and subsets for which different variable values are given.

False

Variables used as input to volume calculations can only be specified through constant values, and not through surface or parameter selection.

False

The volumetric units used are in the Reservoir engineering category.

False

In volumetrics calculations, GOR is dimensionless.

True

The Report file can only be specified as a Document list.

False

Document list output is a text file with a separate file for each realization.

True

Tabular output is presented as an Excel, CSV, or text file with a separate file for each realization.

True

Options such as including realization number in file name cannot be toggled.

False

The order of volume calculations in the Report file cannot be set based on the subsets specified.

False

The Report table option creates a table within RMS with results for all realizations.

True

The Volumetric Table Viewer dialog box consists of four tabs: Data selection, Statistics, Raw data, and Visualization.

False

P10 and P90 values in the Statistics tab reflect high and low side estimates, respectively.

True

Raw data tab presents the calculated volumetric data in a table, accounting for potential undefined values if the job is run for fewer realizations than set for the project.

True

Before running the job, ensure the required Import/Export unit set has been selected for the report output.

True

The main types for volumetrics calculations include Oil/Condensate, Gas, and Water.

False

The formulas used for volumetrics calculations involve variables like porosity, water saturation, and recovery factors.

True

Three outputs can be selected for each volumetrics calculation: Parameter, Zone map, and Total map.

True

Pre-calculated bulk volume cannot be used to speed up later calculations.

False

Area and average thickness can be generated per license boundary only, not per zone.

False

Negative cell volumes can be set to zero but not allowed, providing a choice to check the results.

False

Map layout can be defined by dragging a surface into the Map Layout drop site.

True

To use license boundaries, an open, collapsed polygon must be present.

False

Discrete fluid parameter can be created to describe fluid contact in the grid model.

True

Output location for all the maps selected in the Subtypes section cannot be specified.

False

Subtypes for volume calculations include Bulk, Net, Pore, HCPV, STOIIP, GIIP, and Recoverable.

True

Selecting a grid parameter defining facies is not necessary for Volumetrics Calculation in RMS Software.

False

Study Notes

Volumetrics Calculation in RMS Software

  • Select grid parameter defining facies in the Parameter drop-down list.
  • To use license boundaries, a closed, non-collapsed polygon must be present.
  • Main types for calculations include Oil/Condensate, Gas, and Totals.
  • Subtypes for volume calculations include Bulk, Net, Pore, HCPV, STOIIP, GIIP, and Recoverable.
  • Formulas used to calculate volumetrics options involve variables like porosity, water saturation, and recovery factors.
  • Three outputs can be selected for each calculation: Parameter, Zone map, and Total map.
  • Pre-calculated bulk volume can be used to speed up later calculations, with certain constraints.
  • Area and average thickness can be generated per license boundary or per zone.
  • Discrete fluid parameter can be created to describe fluid contact in the grid model.
  • Negative cell volumes can be set to zero or allowed, providing a choice to check the results.
  • Map layout can be defined by dragging a surface into the Map Layout drop site.
  • Output location for all the maps selected in the Subtypes section can be specified.

Test your knowledge of volumetrics calculations in RMS software with this quiz. Explore grid parameters, calculation types, output options, and key formulas used for volumetrics. Gain insights into handling pre-calculated volumes, defining map layouts, and setting output locations.

Make Your Own Quizzes and Flashcards

Convert your notes into interactive study material.

Get started for free

More Quizzes Like This

RMS Petrophysical Modelling Quiz
26 questions
RMS Petrophysical Modelling
7 questions
RMS Petrophysical Modelling
7 questions
Use Quizgecko on...
Browser
Browser