RMS Volumetrics Quiz
43 Questions
2 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

True or false: To open the Volumetrics dialog box, you can click the Grid under the relevant Grid model in the Data tree, and then select Volumetrics?

True

True or false: The Volumetrics dialog box has three tabs: General Tab, Calculations Tab, and Variables Tab?

False

True or false: A job can only be specified to perform volume calculations and report on the entire grid model, not a subset?

False

True or false: The use of region models in RMS is not explained in the Working with Regions page?

<p>False</p> Signup and view all the answers

True or false: If you click the Save button in the Volumetrics dialog box, it allows you to generate multiple realizations of the results?

<p>True</p> Signup and view all the answers

True or false: RMS calculates the volumes and displays a progress indicator pop up box when running the Volumetrics job for the current project realization?

<p>True</p> Signup and view all the answers

True or false: If you requested a report table and the specified table object already exists but was generated using a different job specification, a warning message is displayed?

<p>True</p> Signup and view all the answers

Map increment option allows users to adjust grid resolution for output maps, with a larger value providing more accurate maps but slower calculations.

<p>False</p> Signup and view all the answers

Fluid contact data from a region attribute table cannot be used in Volumetrics if defined with a template based on standard contacts.

<p>False</p> Signup and view all the answers

Variables used as input to volume calculations can only be specified through constant values.

<p>False</p> Signup and view all the answers

Users cannot specify variables by selecting a variable class, specific variable, and subsets for which different variable values are given.

<p>False</p> Signup and view all the answers

Variable types include oil, gas, and formation variables, each with specific variables and unit measures, defined through the Unit Set Selector in the Tools menu.

<p>True</p> Signup and view all the answers

In the Report file tab, users can only specify the output as a Report file, and not a Report table data object.

<p>False</p> Signup and view all the answers

Associated gas and liquid units in the Report file and table are linked to the units set for STOIIP and GIIP respectively, which are not specified in the Unit Set Selector dialog box accessed from the RMS menu bar under Tools.

<p>False</p> Signup and view all the answers

Maps cannot be output to specific folders in the Data tree including Model QC, General 2D data, Clipboard, and Zones.

<p>False</p> Signup and view all the answers

Input variables for select volumes are entered in the Variables tab, depending on the options selected in the Calculations tab.

<p>True</p> Signup and view all the answers

The Variables tab lists the formulas to be used for selected calculations, with options independent of the input and calculations chosen in previous tabs.

<p>False</p> Signup and view all the answers

Users cannot specify variables by selecting a variable class, specific variable, and subsets for which different variable values are given.

<p>False</p> Signup and view all the answers

Variables used as input to volume calculations can only be specified through constant values, and not through surface or parameter selection.

<p>False</p> Signup and view all the answers

The volumetric units used are in the Reservoir engineering category.

<p>False</p> Signup and view all the answers

In volumetrics calculations, GOR is dimensionless.

<p>True</p> Signup and view all the answers

The Report file can only be specified as a Document list.

<p>False</p> Signup and view all the answers

Document list output is a text file with a separate file for each realization.

<p>True</p> Signup and view all the answers

Tabular output is presented as an Excel, CSV, or text file with a separate file for each realization.

<p>True</p> Signup and view all the answers

Options such as including realization number in file name cannot be toggled.

<p>False</p> Signup and view all the answers

The order of volume calculations in the Report file cannot be set based on the subsets specified.

<p>False</p> Signup and view all the answers

The Report table option creates a table within RMS with results for all realizations.

<p>True</p> Signup and view all the answers

The Volumetric Table Viewer dialog box consists of four tabs: Data selection, Statistics, Raw data, and Visualization.

<p>False</p> Signup and view all the answers

P10 and P90 values in the Statistics tab reflect high and low side estimates, respectively.

<p>True</p> Signup and view all the answers

Raw data tab presents the calculated volumetric data in a table, accounting for potential undefined values if the job is run for fewer realizations than set for the project.

<p>True</p> Signup and view all the answers

Before running the job, ensure the required Import/Export unit set has been selected for the report output.

<p>True</p> Signup and view all the answers

The main types for volumetrics calculations include Oil/Condensate, Gas, and Water.

<p>False</p> Signup and view all the answers

The formulas used for volumetrics calculations involve variables like porosity, water saturation, and recovery factors.

<p>True</p> Signup and view all the answers

Three outputs can be selected for each volumetrics calculation: Parameter, Zone map, and Total map.

<p>True</p> Signup and view all the answers

Pre-calculated bulk volume cannot be used to speed up later calculations.

<p>False</p> Signup and view all the answers

Area and average thickness can be generated per license boundary only, not per zone.

<p>False</p> Signup and view all the answers

Negative cell volumes can be set to zero but not allowed, providing a choice to check the results.

<p>False</p> Signup and view all the answers

Map layout can be defined by dragging a surface into the Map Layout drop site.

<p>True</p> Signup and view all the answers

To use license boundaries, an open, collapsed polygon must be present.

<p>False</p> Signup and view all the answers

Discrete fluid parameter can be created to describe fluid contact in the grid model.

<p>True</p> Signup and view all the answers

Output location for all the maps selected in the Subtypes section cannot be specified.

<p>False</p> Signup and view all the answers

Subtypes for volume calculations include Bulk, Net, Pore, HCPV, STOIIP, GIIP, and Recoverable.

<p>True</p> Signup and view all the answers

Selecting a grid parameter defining facies is not necessary for Volumetrics Calculation in RMS Software.

<p>False</p> Signup and view all the answers

Study Notes

Volumetrics Calculation in RMS Software

  • Select grid parameter defining facies in the Parameter drop-down list.
  • To use license boundaries, a closed, non-collapsed polygon must be present.
  • Main types for calculations include Oil/Condensate, Gas, and Totals.
  • Subtypes for volume calculations include Bulk, Net, Pore, HCPV, STOIIP, GIIP, and Recoverable.
  • Formulas used to calculate volumetrics options involve variables like porosity, water saturation, and recovery factors.
  • Three outputs can be selected for each calculation: Parameter, Zone map, and Total map.
  • Pre-calculated bulk volume can be used to speed up later calculations, with certain constraints.
  • Area and average thickness can be generated per license boundary or per zone.
  • Discrete fluid parameter can be created to describe fluid contact in the grid model.
  • Negative cell volumes can be set to zero or allowed, providing a choice to check the results.
  • Map layout can be defined by dragging a surface into the Map Layout drop site.
  • Output location for all the maps selected in the Subtypes section can be specified.

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

Related Documents

3D volumetrics uses a.docx

Description

Test your knowledge of volumetrics calculations in RMS software with this quiz. Explore grid parameters, calculation types, output options, and key formulas used for volumetrics. Gain insights into handling pre-calculated volumes, defining map layouts, and setting output locations.

More Like This

RMS Petrophysical Modelling Quiz
26 questions
RMS Petrophysical Modelling
7 questions
RMS Petrophysical Modelling
7 questions
RMS Petrophysical Modelling
7 questions
Use Quizgecko on...
Browser
Browser